Crompton current transformers
Primary current: 100 A - 5,000 A
... equipment, 0,72 kV. - Isolation voltage, 3 kV. - Working frequency, 50• 60 Hz. - Short circuit thermal current, Ith=20 In. - Dynamic current, Idyn=2,5 Ith.
Contrel elettronica
Primary current: 1 A - 4,000 A
... those of the measuring transformer. Infact the measuring C.T. is expected to give a saturation of the magnetic circuit with 5P in primary currents while, in the case of protective C.T., ...
Contrel elettronica
Primary current: 500 A - 6,000 A
The TCB-A is a series of current transformers that are specially made for applications that involve power centers and distribution boards for plant expansion or maintenance. The primary ...
Contrel elettronica
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 0 mA - 600 mA
UL2808 XH-SCT-1250 Split Core Current Transformer CTs Specifications: 1.Rated current:0-600A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation Voltage:5400V ...
Jiangyin Spark Electronic Technology Co.,LTD
Secondary voltage: 0 V - 3 V
Primary current: 0 A - 80 A
Secondary current: 0 A - 0.8 A
XH-SCT-T10 Split Core Current Transformer CTs Specifications: 1.Diameter:10mm 2.Rated current:0-80A 3.Rated output:mA or mV(0.333V) 4.Insulation Voltage:3KV 5.Rated Frequency:50HZ/60HZ 6.Operating ...
Jiangyin Spark Electronic Technology Co.,LTD
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 0 mA - 600 mA
BCT-1250 Solid Core Current Transformer CTs Specifications: 1.Rated current:0-600A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation Voltage:5400V CATIII ...
Jiangyin Spark Electronic Technology Co.,LTD
Primary voltage: 0.7 kV
Primary current: 150 A - 500 A
Secondary current: 1, 5 A
Quickly fixing current transformers LCTS series with split core are adapted to easy assembly on the mounting rail without the necessity of disconnecting the current circuit. Owing ...
LUMEL
Primary voltage: 11 V
Secondary voltage: 30 V
Primary current: 300 A
... transducer is loop-powered with current 4-20 mA so needs no direct power supply. It is the first loop-powered Hall effect transformer with 0.5% accuracy on the market. RMS AC/DC loop-powered ...
qeed
Primary voltage: 0 kV - 0.7 kV
Secondary voltage: 0 kV - 0.7 kV
Primary current: 50 A - 6,000 A
Cable/Bus-bar type current transformer with DIN-rail/busbar and panel mounting facility. Rated primary currents from 50 A to 6000A(depends on the model). Secondary current ...
Primary current: 200 A
Function: Transformers are components for detecting residual currents in connection with evaluation units such as DRCM, DMRCD or MFR. Transformers in combination with evaluation units ...
1. Current switches. These units are used to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. ...
Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A
Solid core Current transformer 100A/1A Specifications Rated primary current 100 A Output 1 A Hole diameter 24 mm (0.94 in) Accuracy class
CARLO GAVAZZI
Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A
Solid core Current transformer 120A/5A Specifications Rated primary current 120 A Output 5 A Hole diameter 24 mm (0.94 in) Accuracy class 0.5
CARLO GAVAZZI
Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A
Solid core Current transformer 125A/5A Specifications Rated primary current 125 A Output 5 A Hole diameter 24 mm (0.94 in) Accuracy class 0.5
CARLO GAVAZZI
Primary current: 400 A - 5,000 A
Secondary current: 5 A
... Toroidal Current Transformers are mostly used in cases where all measuring conductors cannot be passed through a toroidal current transformer. CT-1S provides a vectorial ...
... series toroidal current transformers, which are selected according to the cable or busbar thickness, are connected to the current measurement input of the residual current ...
... Moulded case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening ...
Janitza electronics GmbH
... Moulded case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening ...
Janitza electronics GmbH
Primary current: 5 A - 2,500 A
... case current transformer for billing purposes Main features Moulded case current transformer for billing purposes The applicable regulations for kWh measurement devices ...
Janitza electronics GmbH
Primary current: 50 A - 500 A
Frequency: 50 Hz - 60 Hz
... frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment ...
Celsa Messgeräte España S.L.
Primary current: 50 A - 300 A
Frequency: 50 Hz - 60 Hz
... frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment ...
Celsa Messgeräte España S.L.
Primary current: 50 A - 750 A
Frequency: 50 Hz - 60 Hz
... frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment ...
Celsa Messgeräte España S.L.
Primary voltage: 400 V - 700 V
Frequency: 50 Hz - 60 Hz
... the primary - greatly attenuating higher frequency current coupling to the secondaries. Minimum 5" long leads. For more selection check out our 300 Series of universal plate & filament transformers. These ...
The current transformer is part of the control circuit. It is used to measure the current so that the temperature controller can determine the heatsealing band temperature: PEX-W5 ...
Primary voltage: 35 kV - 500 kV
LVB(T) series current transformer is a kind of instrument transformer with oil-paper insulation, inverted structure. Its shell is made of cast aluminum alloy, with secondary coils inside. ...
Primary voltage: 35 kV - 500 kV
Primary current: 4,000 A
Frequency: 50, 60 Hz
LVQB series current transformer has an inverted structure with SF6 gas insulation (Please see the figure). It is connected in series with electric energy measurement, measuring, and relay protection functions. Environment: ...
Primary current: 5 A - 8,000 A
Current and voltage transformers for measurement, precision and protection, and open transformers. Complete range of current transformers, 50 models ...
Electric power: 144 W - 1,320 W
Safety transformer to nach VDE 0551 EN 60742, ICE 742 Prepared to protective class I Protective type IP 00 Thermal class B Nominal ambient temperature ta 60°C Input voltage to DIN IEC 38 AC 400V ...
Secondary voltage: 24 V
Primary current: 24,000 A
for the use in transducer units for surface treatment output voltage 24 V DC 24.000 A
Primary current: 2,500 A - 4,000 A
12 - 24 kV Block Type Design Standard: IEC 60044-1/6, VDE0414, ANSI, GOST On request with capacitive layer On request with barrier
alce elektrik san ve tic as
Primary voltage: 36 kV
Secondary voltage: 70 V - 170 V
Primary current: 3,000 A
36 kV Block Type Design Standard: IEC 60044-1/6, VDE0414, ANSI, GOST On request with capacitive later On request with barrier
alce elektrik san ve tic as
Primary voltage: 7.2 kV - 24 kV
Primary current: 1,500 A
24- 36kV Standard: IEC 60044-1/6, VDE0414, ANSI, GOST
alce elektrik san ve tic as
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase ...
Primary current: 160 A
... audio plug connector(or customized), transient voltage suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor.
Primary current: 600 A
Sigma toroidal current transformer is used in combination with the leakage current protection LV circuit breaker, tripping coil and leakage current detection relay. The ...
SIGMA ELEKTRIK
... ASK measuring transformers belong to DEIF's current transformer range. This type of transformer converts high current to a lower nominal current ...
Protection transformer - SASR/SASK The protection transformers of DEIF are utilized in balanced protection systems for over current and earth fault protection. 15 different physical ...
The Switchgear KSU/SUSK is a summation transformer used to recap the secondary currents. The secondary currents are re-caped to a common secondary signal. This device is equipped with ...
Output power kVA: 20,000 kVA - 40,000 kVA
Primary voltage: 15 V - 20 V
Secondary voltage: 15 kV - 20 kV
Frequency injection transformer in mineral oil, installed in the HVB/HVA source station outside: enables the injection of remote control signals. Main characteristics • Oil filled transformer ...
Primary voltage: 72.5 kV - 420 kV
Oil-Insulated Combined CT/VT up to 420 kV KOTEF utilizes the same components as the individual CTs and VTs. Both transformers are combined in a single metering unit and are available in porcelain or composite. The KOTEF ...
GE Grid Solutions
Primary current: 10, 25, 5 A
The AC/DC sensitive measuring current transformers of the CTUB103 series convert system leakage and fault currents into an evaluable measurement signal. The devices are suitable for detecting ...
BENDER
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining