KIMO probes
... input signal to a low voltage ground referenced signal for display on any Oscilloscope. The product FET input differential probe provides a safe means of measuring circuits with floating potentials up to 1000 V ( DC+ ...
These are LF-190E, LF-210E and LF-250 by Tecpel Co is an Oscilloscope probe which is designed for wide range of applications. For LF-190E, it has a 60 MHz rating and comprises of item 10 and item 1. The item 1 has a rating ...
... heated filter probe has an integrated filter chamber that accepts a glass fibre filter cartridge or a stainless steel sintered filter. Two stages of filtration can be achieved using a 20 micron (or 10 micron) SS sintered ...
The CleanAir single point heated EMC gas sampling probe is available with a 1/4″ or 3/8″ stainless steel heating jacket, a 1″ OD stainless steel sheath and a type K thermocouple. The probe is available ...
... often require high-purity gases. The HPGP-101-C High Pressure Gas Probe System provides reliable in-line contamination monitoring for process gases at line pressure. The High Pressure Gas Probe System ...
Used to locate buried plastic Water Pipes, Gas Pipes and any other non-magnetic utility, Sondes are self-contained transmitters that are used with our cable and pipe locators. Sondes are typically attached to a Flexrod, pushed along ...
Radiodetection
... measurement. Our RF sniffer set includes a total of 5 probes: 4 probes for magnetic field measurement and one for measurement of electric fields. All probes are covered with an insulating ...
... plants with a big steam generating system, and many steam traps. Steam traps control was usually done by ear with a contact probe used as a stethoscope. LKS1000-V.3+ is the 1st ultrasonic detector to have a dedicated ...
Flexible probe 400 mm to detect compressed air, gas, vacuum leaks. This probe is a really handy tool added to the LEAKSHOOTER to find precisely leaks on a comressed air network. Once detected at a ...
... Novapress®, ceramic The SP2200-H sample probes are used for continuous sampling of gases from highly dust-loaded, high-temperature or humid processes. They can be back-purged with a closed sample gas outlet. Gas sample ...
M&C TechGroup Germany GmbH
... the sample probe. Gas sample probe type SP2500‑H/C/I/BB with external ceramic filter type S‑2K150, filter porosity: 2 µm, sample tube or pre‑filter retractable through the sample probe ...
M&C TechGroup Germany GmbH
... sample probe. Gas sample probe type SP2500‑H/C/I/BB‑F with external ceramic filter type S‑2K150, filter porosity: 2 µm, sample tube or pre‑filter retractable through the sample probe ...
M&C TechGroup Germany GmbH
Organic mater levels by measuring UV absorption at the wavelength 254 nm Multiparameters : SAC254, BOD, COD, TOC and turbidity Sensor without reagent or consumable 2 optical path available : - 2mm : wastewater - 50 mm : natural waters Very ...
The new digital TRIPOD of AQUALABO (Brand Ponsel) allows to measure until 8 physico-chemical parameters in the same time dedicated to the quality of waters among the following ones: - pH, ORP, Temperature,- DO (by optical way),- Turbidity ...
The OPTOD (Optical Dissolved Oxygen technology) is based on luminescent optical technology. The OPTOD sensor is approved by the ASTM International Method D888-05 and compliant to ISO 17289. Without calibration requirements and thanks ...
Compact in-situ probe Using heated ZrO2 sensor for wet O2 analysis up to 600°C flue gas temperature With optional special heated solid electrolyte sensor for combustibles measurement Basic-Equipment ...
Twin Element Ultrasonic Probe designed for high-temperature, in-service thickness measurements and corrosion surveys across oil and gas, refining, energy and process sectors. Great wear resistance allows for use on hot ...
... eventually wear down. The gauge will automatically “Zero” the probe to compensate for wear (until there is excessive wear when the probe should be replaced). The gauge will indicate when the probe ...
... crystal probes are for use with the gauge in Multiple-Echo mode to read through and ignore coatings. These have one piezo-ceramic crystal. This crystal both sends and receives the ultrasound energy. The S2C single crystal ...
... or metric sizes with various insertion lengths. Signal Group offer a large range of sample probes for various applications. These can be Heated or Insulated. Probe material include Stainless Steel, Monel, ...
... current traveling through the probe window area. For ease and convenience of performing conducted measurements, all of our current probes utilize the split type clamp-on design. Small and lightweight, ...
A.H. Systems
... range of 10 KHz to 152 MHz the BCP-611 monitoring current probe is a great measurement tool for MIL-STD, CISPR and many automotive specifications. The 1V/A flat response of this current probe makes it ...
A.H. Systems
... measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-614 Current Probe is designed to permit field intensity meters, spectrum ...
A.H. Systems
• Three current ranges: 30A, 300A and 3000A. • Two output sensitivities (300mV and 1V), versatile for measuring instruments. • Input protection up to 600V. • Suitable for any electncal system. • Wide bandwidth, low phase shift. • ...
• Three current ranges: 60A, 600A and 6000A. • Two output sensitivities (600mV and 1V), versatile for measu ring instruments. • Input protection up to 600V. • Suitable for any electrical system. • Wide bandwidth, Iow phase shift. • ...
Type 50GI is a sound intensity probe for direct connection to signal analyzers or data acqusition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones ...
G.R.A.S. Sound & Vibration
Easy-to-use, mobile carpet probe with surface plate, filter, hose and plug-in coupling for surveying pipelines. The very light design makes the related tasks fatigue-free and simple. The wide edge of the flexible carpet ...
Schütz GmbH Messtechnik
The bell probe has an integrated dust and water filter. This gas measurement probe is for gas detection and gas measurement on unpaved surfaces. When the carpet probe can no longer be ...
Schütz GmbH Messtechnik
Schütz Messtechnik has designed this special horizontal probe for the locating of gas leaks as well as gas concentration measurements in open construction trenches. The probe can also be used to help ...
Schütz GmbH Messtechnik
... TOC, DOC, COD, & BOD The UV254 probe/sensor continuously measures the water in real-time. This can be done by either taking a side stream to a flow cell, by fitting inline or immersing in an open channel. The probe ...
Photonic Measurements
... , and common mode rejection, IsoVu Gen 2 probes are setting new standards for isolated probe technology. An Isolated probe uses galvanic (optical) or RF isolation to divorce the reference ...
Microcor® ER Probes are an integral component of the new high-resolution Microcor® system. Special design of the probes provides advanced thermal performance, and reliable operation in all environments ...
Rohrback Cosasco Systems
Clamp Adaptors MODEL 8006 • AC CLAMP ADAPTOR • Model 8006 is designed to measure AC current up to1500A. • It can accommodate up to 60mm-dia conductor or 50mm by 75mm bus-bar.
Probe 1:1-1:10 - HP-3060 60 MHz bandwidth, rated 600 V. The Probe 1:1-1:10 - HP-3060 is a 1:1-1:10 selectable passive high impedance oscilloscope probe with 60 MHz bandwidth (1:10) designed ...
The Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on instruments having an input impedance of 1 MOhm ...
The Differential probe SI-9002 extends the measurement power of oscilloscopes to power semiconductor circuits. This Differential Probe provides any general oscilloscope with a high voltage differential ...
ATR tunnel cells provide a high degree of analytical accuracy. They are ideal for the chemical analysis of liquids in the IR range.
Hellma GmbH & Co. KG
X1 Oscilloscope Probe Body. Cable type : Coaxial. Color : Black / yellow. Standard length : 120 cm (47 ''). Detail : Attenuation X1. Input impedance 45 pF. Bandwidth 25 MHz. Rise time 14 ns.
ELECTRO PJP
... and . We will find the optimum probe for your measuring task from over 100 standard probes, numerous special probes and digital probes. If required, we can also develop ...
WEUVCOD SMART PROBE It is a COD intelligent electrode with a built-in cleaning brush, which uses RS485 communication interface and standard Modbus protocol. It simultaneously measures the absorbance of the water body ...
WEUVCOD SMART PROBE Spectral method organic matter sensors rely on the absorption effect of organic matter on ultraviolet light, and use the 254nm spectral absorption coefficient SAC254 to reflect the important measurement ...
Energy: IEC/EN 62110 Railway: EN 50500 Welding: EN 50505 Induction heating (LF): EN 50519 Electric arc or induction smelting Household appliances: IEC/EN 62233, EN 50366 RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1 Medical: IEC 60601 Research/Labs Electronic/electrical ...
WAVECONTROL
Broadband WP50 Field Probe 10 Hz - 3 kHz E & H field MAIN APPLICATIONS Energy: IEC/EN 62110 Induction heating: EN 50519 Electric arc or induction smelting Workplace assessment: EN 50499 Human exposure assessment: EN ...
WAVECONTROL
1 Hz - 400 kHz E & H field Selective & Broadband MAIN APPLICATIONS Energy: IEC/EN 62110 Railway: EN 50500 Welding: EN 50505 Induction heating (LF): EN 50519 Electric arc or induction smelting Household appliances: IEC/EN 62233, EN ...
WAVECONTROL
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining