... microphone types used in acoustic testing and NVH applications.
Product family / category
- Microphone calibration system (Sound & Vibration DAQ)
Applications
- Low-frequency calibration
Hottinger Brüel & Kjær A/S
... Product overview
Secondary
calibration system designed to calibrate working standard microphones and other types of microphones. Intended for laboratory and calibration-lab use where traceable acoustic measurements are required.
Main ...
Hottinger Brüel & Kjær A/S
... Overview
Designed for measurement and matching of sound intensity microphone pairs, enabling phase, amplitude and pressure-residual intensity index evaluation to support acoustic testing workflows.
Applications
- Phase
Hottinger Brüel & Kjær A/S
Temperature: -200 °C - 2,315 °C
... Industrial Thermocouple Handheld Calibrator • Handheld Thermocouple Calibrator with ±(0.003% Rdg +5 µV) accuracy • Resolution: 0.01° • 500 Hour Battery Life • Simultaneous Source / Measure • MIL-STD Durability • ...
Pressure: 80,000 Pa - 3,500,000 Pa
Voltage: 0 V - 50,000 V
... measurement, which makes it the most accurate calibrator in the portable calibrator class. Field Calibration of Differential Pressure and Pressure Transmitters Calibration of pressure transmitters is required to ...
Temperature: -100 °C - 250 °C
Pressure: 700 mbar - 1,100 mbar
Humidity range: 10 % - 100 %
... ALMEMO® measuring system for calibrating climatic chambers • As per guideline DAkkS-DKD-R 5-7 • Calibration of relative atmospheric humidity at nine points in the climatic chamber • Comprising data logger ALMEMO® 710, one humidity sensor, and eight ...
Ahlborn Mess- und Regelungstechnik GmbH
Temperature: -100 °C - 250 °C
Pressure: 700 mbar - 1,100 mbar
Humidity range: 10 % - 100 %
... ALMEMO® measuring system for calibrating climatic chambers • As per guideline DAkkS-DKD-R 5-7 • Calibration of relative atmospheric humidity at nine points in the climatic chamber • Comprising data logger ALMEMO® 710, one humidity sensor, and eight ...
Ahlborn Mess- und Regelungstechnik GmbH
Temperature: -100 °C - 1,200 °C
Pressure: 0 bar - 700 bar
Humidity range: 10 % - 98 %
... Calibration certificates for sensors and measuring devices • Calibration for temperatures from -100 to +1200 °C • Calibration for humidity from 10 to 98 % r.h. at ambient temperatures from +10 to +95 °C • Calibration for flow velocities from 0.1 ...
Ahlborn Mess- und Regelungstechnik GmbH
... The CS 2890 Power Calibrator/Simulator is a handheld multifunctional four-phase instrument designed for calibrating and adjusting Metrel power quality Class A and Class S analysers as well as simulation of typical voltage and current ...
Voltage: 50 V - 300 V
... The MI 2891 Power Simulator is a multi-purpose three phase power simulator for simulating typical situations in low voltage power supply systems. It is an excellent tool for training, demonstration purposes, or as an electrical didactic tool. MEASURING ...
... PRIMARY CALIBRATOR 4046 SKU: 4046 The Primary Calibrator 4046 has a range of 2.5 to 300 liters per minute (L/min).PRODUCT DETAILS This small, portable, battery-operated unit is lightweight and easy to use. Volumetric ...
... PRODUCT DETAILS The Primary Calibrator 4146 has a range of 0.01 to 20 liters per minute (lpm). This small, portable, battery-operated unit is lightweight and easy to use. Volumetric flowrate is displayed continuously so adjustments to ...
Noise level: 114, 94 dB
... CAL73 sound level calibrator is used to calibrate sound level meters and other sound measurement equipment. You can calibrate 1 inch diameter microphones directly and 1/2 inch microphones using a 1/2 inch adapter supplied with the calibrator. Conforms ...
Temperature: 40 °C - 375 °C
Voltage: 234 V
... Universally applicable and portable Blockcalibrator for immersion-and insertion probes (e.g. Pt 100, Thermocouples) between +40...375°C • Large measuring range +40 ... 375 ° C • 230 VAC power supply • 120mm immersion depth Various interchangeable ...
Temperature: 0 °C - 50 °C
... Partial discharge calibrator KAL 9511 is a successor to the popular Tettex 9216. KAL 9511 covers a wide range of applications. It is compact, easy to use and has the same long battery operation capability of Tettex 9216 but offers ...
Temperature: 5 °C - 40 °C
Pressure: 20 psi - 40 psi
Voltage: 85 V - 265 V
... The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint ...
Teledyne API
Temperature: -10 °C - 70 °C
Pressure: 0 Pa - 100,000 Pa
Voltage: 90 V - 264 V
... for attenuating the display during pressure fluctuations Can be calibrated The portable, battery-operated KAL 84 calibration system combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure ...
halstrup-walcher GmbH
Designed to slip easily into the bed of a pick-up truck, Seraphin® Slip-On Volumetric Calibration Unit can speed the job of calibrating multiple fuel dispensing units, while at the same time, enhancing safety. The unit consists of three 5 gallon or 20 ...
Seraphin Test Measures
... The calibrator KAL 84 is used for calibrating pressure sensors. It represents a combination of a pressure generator (hand pump) and a pressure meter with digital display. The instrument provides a simple means for testing and calibrating ...
Temperature: -200 °C - 1,820 °C
Pressure: 0 psi - 10,000 psi
Voltage: 0 V - 60 V
... •Designed for on-field use, it offers ail advantages of a documenting calibrator. •Measures and generates mV, T/C, Ohms and RTD signais, besides measuring mA. •Output operation simultaneous with mA input. •Internai regulated 24VDC power ...
Temperature: -40 °C - 123 °C
Voltage: 100 V - 240 V
... Interchangeable Single hole Thermowell Inserts Computer Interface & Calibration Software Description Precision Dry Block Calibrator with Interchangeable Thermowells Ideal for quick / fast Site Calibration of RTDs / Bi-Metal Thermometers, ...
Nagman Instruments & Electronics (P) Ltd.
Reference magnets are used to quickly check the calibration of a Gauss/Tesla-Meter. They are calibrated permanent magnets traceable to NIST with an aperture for a Gauss/Tesla-Meter probe to be inserted These devices can be used in conjunction with annual ...
Used during white calibration. Back side of the cover lists calibration data.
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group