Pico dry transformers

204 companies | 1,084 products
power transformer
power transformer

Low frequency (50/60hz) transformers make up the widest and most complete range of Comelit products. It includes laminate and toroid core solutions, encapsulated and non, for PCB assembly, panel assembly, outputs with ...

switch-mode transformer
switch-mode transformer

... isolated from the input. minimal mechanical size, indeed these modules are dimensionally equivalent to an EI30 laminate transformer. High efficiency. In comparison to a linear solution (50% efficiency) with this solution ...

power transformer
power transformer

Comelit develops and produces various types of transformers for switch mode applications. In close collaboration with the client, the product is customized to the end of maximizing its performance and preventing problems ...

power transformer
power transformer
WE-PSPA

Primary voltage: 5 V - 23 V
Secondary voltage: 2,500 V
Primary current: 100 mA - 750 mA

Surface mount AEC-Q200 Variety of turn ratios Operating temperature:-40 °C up to +125 ºC Automotive approved Applications As a Gate Drive Transformator Transformator for Push Pull DC/DC Converter For isolated interfaces RS 485, CAN

See the other products
Würth Elektronik eiSos
isolation transformer
isolation transformer
PAD00 series

Electric power: 1 W
Primary voltage: 3.3 V - 5 V
Secondary voltage: 3.3 V - 15 V

Low profile and small size Designed to comply with IEC 62368 Functional insulation for 400 Vrms continuous operation voltage Operating temperature: -40 °C to +125 °C RoHS compliant Applications Isolated RS-485/RS-232 power supplies Industrial ...

See the other products
BOURNS
pulse transformer
pulse transformer

Primary voltage: 36 kV

... advantages of Cast Resin Traction Transformers are described below: • Worldwide Rail System References, • Working with Global Partners for Railway Applications in the World, • Leader Manufacturer of Customize ...

current transformer
current transformer
CT-1S Series

Primary current: 400 A - 5,000 A
Secondary current: 5 A

... Multiplexer Toroidal Current Transformers are mostly used in cases where all measuring conductors cannot be passed through a toroidal current transformer. CT-1S provides a vectorial sum by using X/5 ...

power transformer
power transformer
TMN230-24-63

Output power kVA: 0.063 kVA - 20 kVA
Primary voltage: 230 V
Secondary voltage: 24 V

isolation transformer
isolation transformer
TRD

Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A

Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...

isolation transformer
isolation transformer
TRD

Primary voltage: 190, 200, 380, 400, 415 V
Secondary voltage: 24, 48, 110, 220, 12 V
Secondary current: 0 A - 10,000 A

Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor) GENERAL SPECIFICATIONS Internal isolation transformer ...

power transformer
power transformer

Output power kVA: 50 kVA - 2,500 kVA
Secondary voltage: 1.1 kV - 36 kV
Frequency: 50, 60 Hz

STD Cast Resin Transformers have at least one of the two windings embedded on an autoclave mould, at vacuum values close to zero with epoxy resin. The other winding can also be cast in H class. STD Cast Resin Transformers ...

electrical power supply transformer
electrical power supply transformer

Transformers for switched sources are becoming more relevant in our production chain. These transformers are used in different applications and sectors. The types of switching power supplies are different ...

See the other products
Transformadores JESIVA,S.L.
electrical power supply transformer
electrical power supply transformer

At JESIVA, we can design and manufacture any type of high frequency transformer under the specific request of the client. We highlight different types of special assemblies: Stacking of different core blocks. Wiring or ...

See the other products
Transformadores JESIVA,S.L.
electrical power supply transformer
electrical power supply transformer

Primary voltage: 0.5 V - 1,000 V
Secondary voltage: 0.5 V - 1,000 V

... even auto resettable thermal protectors that act if windings overheat and if the transformer temperature drops. After that it works again automatically. - Transformers are manufactured under the EN-61558 ...

See the other products
Transformadores JESIVA,S.L.
current transformer
current transformer
0905349

... case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening and forms the primary circuit for the plug-on ...

See the other products
Janitza electronics GmbH
current transformer
current transformer
1503206

... case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening and forms the primary circuit for the plug-on ...

See the other products
Janitza electronics GmbH
current transformer
current transformer
0914813

Primary current: 5 A - 2,500 A

Moulded case current transformer for billing purposes Main features Moulded case current transformer for billing purposes The applicable regulations for kWh measurement devices can be fulfi lled with ...

See the other products
Janitza electronics GmbH
current transformer
current transformer
ASTR14

Primary current: 50 A - 500 A
Frequency: 50 Hz - 60 Hz

• unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with plus minus screws (2 Nm) • integrated secondary terminal caps General Electrical ...

See the other products
Celsa Messgeräte España S.L.
current transformer
current transformer
AST210s

Primary current: 50 A - 300 A
Frequency: 50 Hz - 60 Hz

• unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with plus minus screws (2 Nm) • integrated secondary terminal caps General Electrical ...

See the other products
Celsa Messgeräte España S.L.
current transformer
current transformer
AST315

Primary current: 50 A - 750 A
Frequency: 50 Hz - 60 Hz

unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with plus minus screws (2 Nm) • integrated secondary terminal caps General Electrical ...

See the other products
Celsa Messgeräte España S.L.
isolation transformer
isolation transformer
KFD0 SCS

Electric power: 0 W - 0.675 W
Primary voltage: 20 V - 30 V
Secondary voltage: 32.1 V

application: Digital two-wire transmitter converts Pt-100, DIN EN 60751 measuring resistors into a 4…20mA current signal. For installation on a standard rail according to EN50022 (DIN, top hat rail). Case:Plastics Case dimensions:B ...

distribution transformer
distribution transformer
A0-A10 AK

Electric power: 252 W - 3,420 W
Output power kVA: 100 kVA - 3,150 kVA
Primary voltage: 17.5 kV

The transformers are designed and manufactured according the following standards and equipped by the following accessories: CEI EN 60076-11 : 2019 ( EN 60076- 11 : 2018 – IEC 60076-11 : 2018 ) CEI EN 50588-1 : 2018 ...

distribution transformer
distribution transformer
A0-A10 AK

Electric power: 252 W - 3,420 W
Output power kVA: 100 kVA - 3,150 kVA
Primary voltage: 24 kV

The transformers are designed and manufactured according the following standards and equipped by the following accessories: CEI EN 60076-11 : 2019 ( EN 60076- 11 : 2018 – IEC 60076-11 : 2018 ) CEI EN 50588-1 : 2018 ...

distribution transformer
distribution transformer
A0-10 AK DTP series

Electric power: 290 W - 3,209 W
Output power kVA: 100 kVA - 2,500 kVA
Primary voltage: 24 kV

The transformers are designed and manufactured according the following standards and equipped by the following accessories: CEI EN 60076-11 : 2019 ( EN 60076- 11 : 2018 – IEC 60076-11 : 2018 ) CEI EN 50588-1 : ...

power transformer
power transformer
160-161 Series

Secondary voltage: 5 V - 120 V

20 output voltages to choose from (5 - 120VAC R.M.S.) Six VA size models available from - .5 to 24 VA Vertical mount, split bobbin design. 1.2, 4.4, 10, 24 VA models are non-concentric wound. 0.5 and 1 VA are both concentric wound. Low ...

See the other products
Hammond
pulse transformer
pulse transformer

... / process, ROPEX RES impulse heatseal transformers are custom sized and built to suit your heat-sealing application. ROPEX provides the impulse transformer that best fits your requirements. Be it ...

current transformer
current transformer
PEX-W5

The current transformer is part of the control circuit. It is used to measure the current so that the temperature controller can determine the heatsealing band temperature: PEX-W5 standard version with additional UL ...

distribution transformer
distribution transformer
SC(B) series

Output power kVA: 30 kVA - 2,500 kVA
Primary voltage: 10 kV

The epoxy resin dry-type transformer uses electrical oriented silicon steel as the core material, and the coil is cast with epoxy resin. The product has good fire resistance, moisture resistance, no pollution, ...

distribution transformer
distribution transformer
SC(B) series

Output power kVA: 30 kVA - 2,500 kVA

The amorphous alloy dry-type transformer uses amorphous alloy as the core material, and the coil is cast with epoxy resin. The product has good fire resistance, moisture resistance, no pollution, flame ...

measurement transformer
measurement transformer
TYD series

Frequency: 50, 60 Hz

Capacitor voltage transformer series products are suitable for current, electric energy measurement and relay protection in a system with effectively earthed neutral with rated voltage 35kV to 1000 kV and rated frequency ...

See the other products
Siyuan Electric Co., Ltd
current transformer
current transformer
LVQB series

Primary voltage: 35 kV - 500 kV
Primary current: 4,000 A
Frequency: 50, 60 Hz

LVQB series current transformer has an inverted structure with SF6 gas insulation (Please see the figure). It is connected in series with electric energy measurement, measuring, and relay protection functions. Environment: ...

See the other products
Siyuan Electric Co., Ltd
instrument transformer
instrument transformer
JED(S)H series

Primary voltage: 66 kV - 500 kV
Frequency: 50, 60 Hz

... protection, provide voltage signals for control devices. Electronic transformer is the trend of meter transformer development. Contrast to the conventional instrument transformer, electronic ...

See the other products
Siyuan Electric Co., Ltd
distribution transformer
distribution transformer
Green T.HE

Output power kVA: 0 kVA - 3,150 kVA
Primary voltage: 10 kV - 33 kV
Secondary voltage: 400 V

... T.HE resin transformers are manufactured according to EN 50708-2-1 and comply with the provisions of Regulation 2019/1783 of the European Commission, which describes the mandatory requirements for the eco-friendly design ...

current transformer
current transformer
TA series

Primary current: 5 A - 8,000 A

... range of IME transformers is extremely rich and complete. The characteristics of these transformers, in terms of precision and ease of installation, mean that they are used in many application areas. ...

isolation transformer
isolation transformer
SU series

Output power kVA: 0.06 kVA - 1 kVA
Primary voltage: 230 V - 690 V
Secondary voltage: 6 V - 48 V

safety isolating / Control Transformer, IP00 Open single-phase safety isolating transformer designed and tested according to norm EN61558-2-6. Separate insulated windings and protected against dust, ...

toroidal transformer
toroidal transformer

Primary voltage: 500 V

... toroidal-core transformer Features – Toroidal core R 10 – Compact design – Suitable for automatic insertion – For reflow and vapor phase soldering – Qualified to AEC-Q200 Applications EMC devices, pulse transformers, RF ...

power transformer
power transformer

Chip inductor / transformer Features – Flat design – Transformer – Ceramic base or one piece ferrite Applications Mobile radio, satellite TV, RF circuit

power transformer
power transformer

Type:1 Turns coil 1:2,5 Turns coil 2:2,5 Package:SM-T7 Lower 3 dB-cutoff frequency [MHz]:3,8 Upper 3 dB-cutoff frequency [MHz]:970

isolation transformer
isolation transformer
TTGN series

Electric power: 0.05, 0.1, 0.2 kVA
Primary voltage: 230, 120 V
Secondary voltage: 110, 230 V

Isolating transformers, according to the VDE and EN instructions. Type TTGN 2 is a plug-in unit which is plugged directly into the 230 V main socket. Types TTGN 20 mounted in a steel-case with a handgrip. Types ...

See the other products
HSGM
electrical power supply transformer
electrical power supply transformer
2240

Primary voltage: 115, 230 V
Secondary voltage: 12, 24 V
Secondary current: 1.3, 2.5 A

Transformer Double-isolated transformer 3.75 kVAC isolation voltage 30 VA ring core transformer Thermal overload protection 12 or 24 VAC secondary voltage ...

power transformer
power transformer

Elektrotechnik's controllable transformer is a ready-to-connect power supply solution. This transformer aids in providing a power supply either as a 24V control voltage or 8000 V anode voltage. The manufacturer ...

See the other products
J. Schneider Elektrotechnik
air-insulated transformer
air-insulated transformer

Electric power: 10,000,000 W
Primary voltage: 36 kV

The Air Insulated Dry-type Transformer can be utilized in various applications as a power converter, starting unit, distribution transformer and others. It is incorporated ...

See the other products
J. Schneider Elektrotechnik
water-cooled transformer
water-cooled transformer

Electric power: 10,000,000 W
Primary voltage: 36 kV

J. Schneider Elektrotechnic are air-insulated dry type transformers that runs with power ranging up to 10 MVA power level and has a voltage level of 36 kV. This air-insulated MV transformers ...

See the other products
J. Schneider Elektrotechnik
current transformer
current transformer

Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V

The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side ...

isolation transformer
isolation transformer
ENTIST series

Electric power: 0.025 kVA - 0.63 kVA
Primary voltage: 230, 400 V
Secondary voltage: 230, 400 V

ENTES isolating transformers ensure the safe operation on the secondary side by isolating them from the primary voltage. Input output voltages of isolating transformers are fixed (230 or 400V). The electrical ...

current transformer
current transformer

... neutral cables should be passed through the toroidal transformer. The ground wire must not pass through the toroidal transformer. The cables should be routed through the center of the toroidal transformer ...

See the other products
SIGMA ELEKTRIK
instrument transformer
instrument transformer
ASR, ASK series

These ASR/ASK measuring transformers belong to DEIF's current transformer range. This type of transformer converts high current to a lower nominal current value, hence allowing the use ...

current transformer
current transformer
SASR, SASK series

Protection transformer - SASR/SASK The protection transformers of DEIF are utilized in balanced protection systems for over current and earth fault protection. 15 different physical sizes of the ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us