Isolation transformer TRD
encapsulatedindustrialfor medical applications

Isolation transformer - TRD - Tescom - encapsulated / industrial / for medical applications
Isolation transformer - TRD - Tescom - encapsulated / industrial / for medical applications
Add to favorites
Compare this product

Characteristics

Type
isolation
Configuration
encapsulated
Applications
industrial, for medical applications, for data centers
Electrical characteristics
three-phase, voltage
Mounting
floor-standing
Other characteristics
control, rectifier, signal, galvanically-isolated
Primary voltage

190 V, 200 V, 380 V, 400 V, 415 V

Secondary voltage

12 V, 24 V, 48 V, 110 V, 220 V

Secondary current

Max.: 10,000 A

Min.: 0 A

Frequency

50 Hz, 60 Hz

Description

Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor) GENERAL SPECIFICATIONS Internal isolation transformer at input Full controlled conventional rectifier Smart control and high reliability with DSP (Digital Signal Processor) Float charge, equalizing charge and boost charge modes Automatic and manual charge modes Low output voltage ripple and high reliability 2x16 character LCD display, showing measurements, status and alarm messages Soſt start Led displays for easy observation of rectifier status. Audible alarm Programmable current limitation Operation as voltage source or current source Calibration of measurements from front panel Language selection from front panel. (English / German / Turkish / Dutch / Portuguese) DC Low / High, Line failure, Over temperature, Short circuit protections Ability to program all operation parameters (Password protected) Programable alarm relay contact outputs (4 standart, up to 16 relays as option) Possibility of monitor and control over RS232-RS485 Modbus communication Earth leakage monitoring (DC leakage) Log records with date and time stamp up the 200 events OPTIONS Active parallel (current sharing) operation up to 4 devices Ability to monitor batteries and battery low alarm, even when the AC input fails. Battery temperature compensation Easy observation via analog gauges Battery test with adjustable voltage and duration Transducers for input / output voltage(s) / current(s) (4-20mA and 0-10V) 12 pulse option to limit input current distortion Input Power / kVA / kW measurement Internal cabinet light / cabinet anticondensation heater

Catalogs

No catalogs are available for this product.

See all of Tescom‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.