- Electricity - Electronics >
- Energy: Production and Distribution >
- Floor-standing transformer
Floor-standing transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Electric power: 0.5 kVA - 5 kVA
Primary current: 1.36 A - 12.86 A
Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, control transformer, ...
Output power kVA: 0.005 kVA
Primary voltage: 3 kV
Secondary voltage: 720, 333 V
Article features 1. - This Winding current transformer is mostly used for new installations, as the circuit must be interrupted here. 2. - Most cost-effective and most common variant. 3. - Currently the most compact design ...
Celsa Messgeräte GmbH
Output power kVA: 0.00125, 0.0025, 0.005, 0.0075, 0.01 kVA
Primary voltage: 3 kV
Secondary voltage: 720, 333 V
1. - This clip-on current transformer is mostly used for new installations, as the circuit must be interrupted here. 2. - Short-circuiting of the current transformer when the secondary terminal cover ...
Celsa Messgeräte GmbH
Output power kVA: 0.0013, 0.005, 0.01, 0.015, 0.02 kVA
Primary voltage: 3 kV
Secondary voltage: 720, 333 V
1. - This clip-on current transformer is mostly used for new installations, as the circuit must be interrupted here. 2. - Short-circuiting of the current transformer when the secondary terminal cover ...
Celsa Messgeräte GmbH
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
Dry type transformer. All transformers are tropicalized with anti-flash varnish: • Protection against corrosive environments. • Greater electrical insulation. • High compaction power. • Noise level reduction. • ...
POLYLUX S.L.
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
Dry type transformer. All transformers are tropicalized with anti-flash varnish: • Protection against corrosive environments. • Greater electrical insulation. • High compaction power. • Noise level ...
POLYLUX S.L.
Output power kVA: 3.15 kVA - 50 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
Dry type transformer Anti-flash varnish finish, offering: • Protection against corrosive environments • Increase of electrical isolation • High compression capacity • Reduction of noise level • Increase of product's ...
POLYLUX S.L.
Electric power: 252 W - 5,500 W
Output power kVA: 100 kVA - 3,150 kVA
This kind of transformer complies with EU Ecodesign Direc- tive (EU548/2014) and with the IEC 60076-11:2018-10 standard. It makes it possible to reduce energy consumption and, as a consequence, to reduce greenhouse emissions. ...
Tesar Srl
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Secondary voltage: 0 kV - 765 kV
... planners have a clear picture of the required capabilities of their new transformer. This Siemens Energy approach combines expertises to give customers a perfectly tailored transformer – the most cost-efficient ...
Siemens Energy – Power transmission
Output power kVA: 7,500 kVA
GE Prolec’s distribution transformers are designed for the diverse mining, oil and gas and distribution markets of North America and international applications. Our distribution substation transformers ...
GE Grid Solutions
Output power kVA: 405,200, 700,000, 1,000,000, 3,000, 1,500,000 kVA
Primary voltage: 1,000 kV
Secondary voltage: 800, 66, 500, 750, 1,000 kV
... featured in the performance of high reliability, low loss, low noise, low temperature rise, low partial discharge etc. The transformer is built into the wind generator nacelle, which can realize the local voltage boost ...
Primary voltage: 36 kV - 800 kV
Primary current: 4,000 A
... customer-tailored solutions IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators. Hitachi Energy current transformers ...
Hitachi Energy
Primary voltage: 21,400 V
Primary current: 600 A - 1,000 A
Frequency: 50 Hz
Downstream of the HVB/HVA transformer, compensation impedances equip MV networks with neutral point connection (aerial-underground rural networks). Developed as part of the Enedis MALTEN project and installed in source ...
Cahors
Primary voltage: 420 kV
Secondary voltage: 36 kV - 800 kV
Primary current: 0 A - 4,000 A
... customer-tailored solutions IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators. Hitachi ABB Power Grids current transformers ...
ABB AG
Output power kVA: 1.5 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
... RS PRO portable isolation transformer can be used to isolate a standard European 230 V mains voltage supply. It has a high-quality design that’s light, robust and is made with your safety in mind. The separating transformer ...
Electric power: 0.1 W - 3.2 W
Primary voltage: 208 V - 600 V
Secondary voltage: 24 V - 230 V
› Very good switch-on behaviour thanks to reduced starting currents › High power density due to a compact construction design › Very good corrosion protection and low noise thanks to BLOCK IMPEX vacuum impregnation › Quick to cable ...
Electric power: 90,000 W - 180,000 W
... all Piller products are fully trained. The APOJET AJT step down transformer (Gatebox) is designed to step down the high 400Hz transmission voltage supplied by a centralised Ground Power System. The ...
Electric power: 3,600, 7,000, 2,000 W
Primary voltage: 115, 230 V
Secondary voltage: 115, 230 V
Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry ...
The head type IOSK oil paper insulated current transformers follows the current IEC and IEEE/ANSI standards. It is outstanding in controlling insulation stress using fine graded bushing. The advantages of using fine graded ...
Trench Group
Electric power: 30,000 kVA - 1,000,000 kVA
The generator step up transformer, manufactured by Avantha, is suitable for producing distribution transformer that ranges from 30 mVA up to 1000 mVa ranges with a maximum 765 KV for both voltage sides ...
CG Power Systems
Electric power: 0.01 kVA - 31.5 kVA
This TRT 33 power isolating transformer is a dry type transformer. The transformer is meant for voltage changes with galvanic isolation whenever it is necessary to change the neutral ...
Output power kVA: 3 kVA - 500 kVA
Secondary voltage: 600 V
Applications • CNC machine • Food processing factory • High-tech electronic factory • Iron works • Chemistry factory • For harsh environment used Capacity Voltage level: 600V or below Single phase: 3~150kVA Three phase: 3~500kVA Features • ...
Riye Electric
Primary voltage: 1,200, 720 V
Primary current: 40 A - 7,500 A
Secondary current: 1, 5 A
... current transformer range, these measuring transformers convert high current into lower nominal current value, thus making it possible to use instruments and relays with standardised values of rated current. Part ...
DEIF
Electric power: 7.5 kVA - 440 kVA
Primary voltage: 460 V - 575 V
Secondary voltage: 133 V - 460 V
... SCR (Silicon Control Rectifier) variable speed motor drive applications, a transformer is needed to magnetically isolate the incoming line from the motor drive. The transformer must also provide a voltage ...
SolaHD
Output power kVA: 25 kVA - 10,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
... Type Transformers from 25 kVA up to 10.000 KVA up to 36 kV voltage class. Cast Resin Transformers are a cost-effective and convenient alternative to traditional high voltage Oil Immersed Power and Distribution ...
Timsan Transformateur
Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...
Tescom
Output power kVA: 25 kVA - 3,150 kVA
Primary voltage: 7.2 kV - 36 kV
Frequency: 50, 60 Hz
... distribution oil conservator Transformers • MV / MV oil immersed Transformers • LV / LV dry-type or oil immersed Transformers • Special transformers • Reactors • ...
Electric power: 185 W - 3,000 W
Output power kVA: 40 kVA - 2,500 kVA
Primary voltage: 24 kV
The transformers can be available with oil expansion tank or hermetic version , and they are designed and manufactured according the following standards and equipped by the following accessories: • CEI EN 60076-1:2015 ...
La Newton Trasformatori S.p.A,
We produce systems for measurement transformers with various types of resin (epoxy, polyurethane, etc.) • Fully automated production lines • Positioning on the X-Y axes for automated resin coating • System for ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining