- Electricity - Electronics >
- Energy: Production and Distribution >
- Through-hole transformer
Through-hole transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary voltage: 600 V
Our Bulletin 1411 Current Transformers (CTs) are low voltage transformers for various power measurement devices and applications, including protective relays, analog devices, transducers, and PowerMonitor™ products. • Includes low ...
CCV allows the exact measurement of high voltages and transmission of carrier currents from 30 to 500 kHz. The main benefits of this are its superior transient response, tough and leak proof design and easy transport and installation. ...
Alstom Grid
High-frequency current transformer for medium-voltage power cables The MCT 085 high-frequency current transformer (HFCT) is specifically designed for offline or online partial discharge (PD) measurement on medium-voltage (MV) cables. ...
Primary current: 25 mA - 1,000 mA
Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Ignition current up to 3 A Turns ratio up to 3:1 Ignition currents : 0.1 to 3 A Rise time : 0.3 to 2.3 µs Frequency : ≤ 40000 Hz Attenuation performance ...
Primary current: 40 A - 250 A
Secondary current: 5 A
Frequency: 40 Hz - 60 Hz
Measurement current transformers for currents from TAM series Modular LV analog current transformers, 2 modules width, from DIN bar for currents
Electric power: 0.01, 0.125, 0.02, 0.015 W
Primary current: 0.3 mA - 11.5 mA
Frequency: 400 Hz - 250,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures (220º C) of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Electric power: 0.062 W - 0.75 W
Primary current: 0.5 A - 31.6 A
Frequency: 400 Hz - 100,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Electric power: 0.1 W - 0.6 W
Primary current: 0.4 mA - 30 mA
Frequency: 300 Hz - 75,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Frequency: 45 Hz - 65 Hz
MRC022 TRMS Current Transformer with integrated Transducers hole Ø22 Selectable input 5÷30A with passive output 4-20 mA (2 wires technology) TRMS Multirange current transformers, with loop-powered 4-20mA output (also called “passive”), ...
FRER
Primary current: 5 A - 8,000 A
Frequency: 50 Hz - 60 Hz
selfestinguishing thermoplastic material - UL94-V0 operating frequency - 50-60 Hz insulation reference voltage - 0,72 kV test voltage - 3kVx1'50 Hz insulation - dasse E protection degree - IP 20 continuous overcurrent - 1,2 In rated ...
FRER
Primary current: 800 A - 5,000 A
Frequency: 50 Hz - 60 Hz
selfestinguishing - thermoplastic material - UL94-V0 operating frequency - 50-60 Hz insulation reference voltage - 0,6 kV test voltage - 3 kV x 1'50 Hz insulation - dasse H protection degree - IP 00 protection degree with terminal ...
FRER
Electric power: 10 W - 50 W
P025 Planar Transformers (10W to 50W) Patented (U.S. PAT. 7,129,809) design with superior thermal management Rated power 10W-50W / Frequency range 300-500kHZ Surface mount (SMD) or through hole (TH) Topology - Forward (w/active rest), ...
StandexMeder Electronics GmbH
Primary current: 20 A
The CSB is a custom current transformer that is manufactured by standex-Meder electronics. It is built with a primary and secondary winding whose controls are incorporated into a computer. This compact device is less costly, and is varnish ...
StandexMeder Electronics GmbH
Electric power: 50 W - 200 W
Rated power 50W-200W / Frequency range 175-300kHZ Surface mount (SMD) or through hole (TH) Topology - Half Bridge, Forward (w/active rest), Flyback Current rating max. SMD=50A, TH = +30% Isolation voltage pri-sec/pri-core 500-2,000VDC Soft ...
StandexMeder Electronics GmbH
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
EcoPlus2030: The transformer that reduces environmental impact without compromising effectiveness and efficiency, designed with advanced materials to reduce CO2 emission. Our transformers are designed following eco-friendly principles, ...
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection interface • ...
The production of cast resin power transformers can be divided in: Standard Production, which includes distribution transformers with rated power up to 3.150 kVA and voltage insulation level up to 36 kV. Customized Production, ...
Output power kVA: 50 kVA - 1,600 kVA
Primary voltage: 12 kV
Frequency: 50 Hz
ZGS-Z(H)/12 combined transformer (American box substation) is a series of products developed by Tianan Electric after digesting and absorbing foreign advanced technology. It is used in 10/0.4kV, 50Hz power distribution system. The rated ...
Output power kVA: 630 kVA - 2,500 kVA
Primary voltage: 10, 35 kV
The ZGS-ZG series of combined photovoltaic transformers is a series of products developed by Tianan Electric to meet the needs of domestic and foreign users in photovoltaic power generation projects. It is the earliest manufacturer of ...
Output power kVA: 800 kVA - 3,400 kVA
Primary voltage: 35, 10 kV
The ZGS-ZF series wind power combined transformer is a series of products developed by Tianan Electric to meet the needs of wind power projects of domestic and foreign users. It is the earliest manufacturer of similar products in China ...
Primary voltage: 0 V - 10 V
Primary current: 60 A - 600 A
Secondary current: 0 A - 0 A
Current transformer and measuring transducer in one housing The current transformer measuring transducers of the SCMU series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), ...
Primary voltage: 230, 24 V
Primary current: 10 A - 600 A
Secondary current: 4 A - 20 A
The current transformer measuring transducers of the SMU/I series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), rectified (averaging) and converted into a proportional, direct ...
TAB1- closed current transformers /5A TAB1: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting the bars both horizontally and ...
TAB2 - closed current transformers /5A TAB2: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting the bars both horizontally ...
TAB3 - closed current transformers /5A TAB3: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting the bars both horizontally ...
Output power kVA: 0.01 kVA
Primary current: 5 A
- Ratio x/5A - Accuracy class 0.5 and 0.2S Screw mounting
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 0 mA - 600 mA
UL2808 XH-SCT-1250 Split Core Current Transformer CTs Specifications: 1.Rated current:0-600A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation Voltage:5400V CATIII 600V or CATIV 250V 5.Rated Frequency:50HZ/60HZ 6.Operating ...
Jiangyin Spark Electronic Technology Co.,LTD
Secondary voltage: 0 V - 3 V
Primary current: 0 A - 80 A
Secondary current: 0 A - 0.8 A
XH-SCT-T10 Split Core Current Transformer CTs Specifications: 1.Diameter:10mm 2.Rated current:0-80A 3.Rated output:mA or mV(0.333V) 4.Insulation Voltage:3KV 5.Rated Frequency:50HZ/60HZ 6.Operating Temperature:-15℃to 60℃ 7.Flame ...
Jiangyin Spark Electronic Technology Co.,LTD
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 0 mA - 600 mA
BCT-1250 Solid Core Current Transformer CTs Specifications: 1.Rated current:0-600A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation Voltage:5400V CATIII 600V or CATIV 250V 5.Rated Frequency:50HZ/60HZ 6.Operating ...
Jiangyin Spark Electronic Technology Co.,LTD
Electric power: 10,000,000 W
Primary voltage: 36 kV
J. Schneider Elektrotechnic are air-insulated dry type transformers that runs with power ranging up to 10 MVA power level and has a voltage level of 36 kV. This air-insulated MV transformers expositions the lowest fire load and the highest ...
Electric power: 10,000,000 W
Primary voltage: 36 kV
The Air Insulated Dry-type Transformer can be utilized in various applications as a power converter, starting unit, distribution transformer and others. It is incorporated with the ability to deliver a power level of 10 MVA under a voltage ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 0 V - 440 V
Secondary voltage: 12, 24, 48, 110, 230 V
CL Range CL Range Control Panel Transformers offering 230V with input tappings or 400V with input tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and welding ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 15 V - 400 V
Secondary voltage: 0 V - 230 V
MCL Range MCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and welding machines; ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 220 V - 415 V
Secondary voltage: 12, 24, 48, 115, 230 V
SCL Range SCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and welding machines; ...
1. Current switches. These units are used to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. Current converters. These units converts the primary ...
Primary current: 5 A - 450 A
Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply
IME Spa
Primary current: 10, 25, 5 A
The AC/DC sensitive measuring current transformers of the CTUB103 series convert system leakage and fault currents into an evaluable measurement signal. The devices are suitable for detecting fault currents with smooth DC components. ...
BENDER
Primary current: 10 A - 100 A
Frequency: 15 Hz - 400 Hz
The highly sensitive W0-S20…W5-S210 series measuring current transformers convert residual currents up to 100 A into evaluable RCM or EDS signals. The CTs are connected to the respective evaluator by two wires. Depending on the connecting ...
BENDER
Primary current: 10 mA - 100,000 mA
Frequency: 50 Hz - 400 Hz
The highly sensitive split-core-type WS… series measuring current transformers convert residual currents of 10 mA…100 A into evaluable RCM or EDS signals and can be retrofitted to existing electrical installations where disconnection ...
BENDER
Primary voltage: 400 V - 700 V
Frequency: 50 Hz - 60 Hz
Universal primary with taps for 100, 120, 220 or 240 VAC, 50/60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only) Designed for preamps, low power amps, general replacement, test equipment, etc. Economical, open frame, chassis mount ...
Primary current: 5 A - 8,000 A
Current and voltage transformers for measurement, precision and protection, and open transformers. Complete range of current transformers, 50 models from 1A to 8kA The first link in the measurement chain is represented by devices which ...
Primary voltage: 0 kV - 0.7 kV
Primary current: 0 A - 5,000 A
Mainly are used where it is imposible or difficult to measure currents directly. They are special configurations of transformers which transform the primary current into a (mostly) lower secondary current and which separete (galvanicaly) ...
alce elektrik san ve tic as
Primary voltage: 0 kV - 0.7 kV
Primary current: 0 A - 5,000 A
Mainly are used where it is imposible or difficult to measure currents directly. They are special configurations of transformers which transform the primary current into a (mostly) lower secondary current and which separete (galvanicaly) ...
alce elektrik san ve tic as
Primary voltage: 0 kV - 0.7 kV
Primary current: 0 A - 5,000 A
Mainly are used where it is imposible or difficult to measure currents directly. They are special configurations of transformers which transform the primary current into a (mostly) lower secondary current and which separete (galvanicaly) ...
alce elektrik san ve tic as
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side delivers isolation ...
Electric power: 0.025 kVA - 0.63 kVA
Primary voltage: 230, 400 V
Secondary voltage: 230, 400 V
ENTES isolating transformers ensure the safe operation on the secondary side by isolating them from the primary voltage. Input output voltages of isolating transformers are fixed (230 or 400V). The electrical connection is done via terminal ...
Primary current: 0 mA - 2.5 mA
Characteristics:Combined voltage current transformer. Power to be measured works with current–limiting resistance. Adopt permalloy core, epoxy resin encapsulated, PCB welding, mounting height 14mm. Application: for voltage load remote ...
YHDC Dechang Electric
Primary current: 0 mA - 5 mA
Characteristics:TV19 is current type voltage transformer, using ultracrystalline core. Primary current will be different according to different voltage working on the current-limiting resistance. And there will be a same current at secondary ...
YHDC Dechang Electric
It uses EI high quality silicon steel sheet.The installation height is 25.5mm.applicable for triggering single or double narrow pulse SCR below 100A.
YHDC Dechang Electric
Primary current: 20 A - 5,000 A
Low Voltage Current Transformers convert the primary currents which are from 20A to 5000A into 1A or 5A as secondary current in requested Accuracy and power Value . Sigma Current Transformers are produced in 9 different frame for various ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining