Opening transformers

Do you need help making a decision?  Take a look at our buying guide
15 companies | 51 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
Search
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}} {{#each product.productTagAssociationList}}
{{/each}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}} {{#each product.productTagAssociationList}}
{{/each}}
{{/each}} {{/pushedProductsPlacement5.length}}
current transformer
current transformer
TDA060

Frequency: 47 Hz - 450 Hz

... Split Core Toroidal Transformer Ø60 for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • nominal frequency 47...450Hz • operating frequency 25...10kHz -3dB • power-frequency withstanding voltage 3kV 50Hz, 1 min. • ...

See the other products
FRER
current transformer
current transformer
TDA110

Frequency: 47 Hz - 450 Hz

... Split Core Toroidal Transformer Ø110 for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • operating frequency 25...10kHz -3dB • power-frequency withstanding voltage 3kV 50Hz, 1 min. • installation category CAT. III ...

See the other products
FRER
current transformer
current transformer
TDA160

Frequency: 47 Hz - 450 Hz

... Split Core Toroidal Transformer Ø160 for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • operating frequency 25...10kHz -3dB • power-frequency withstanding voltage 3kV 50Hz, 1 min. • installation category CAT. III ...

See the other products
FRER
measurement transformer
measurement transformer
MCT 120

... Partial discharge measurements on power cables The MCT 120 high-frequency current transformer (HFCT) is specifically designed for periodic partial discharge (PD) measurement and diagnostics on high-voltage cable systems. The MCT 120 ...

current transformer
current transformer
SC3 series

Primary current: 125 A

... Description Efficient current transformers that have been specially designed to be installed on top of a switch. The most important feature of these split-core transformers is that they are very easy to install. In other ...

current transformer
current transformer
CT80ABR

... Core Current Transformer – CT80 ABR Electric Energy Measurement Transformer for remote management in Low Voltage Open-core current transformers that facilitate assembly without disconnection ...

current transformer
current transformer
CT20N

Primary current: 0 A - 1,200 A

... Narrow Profile Current Transformers – CT20N Narrow profile current transformer This type of transformer stands out for its compact size, which facilitates assembly in small spaces Protection ...

measurement transformer
measurement transformer
D1C9002-01

Primary voltage: 184 V - 276,000 V
Secondary voltage: 184 MV - 276 MV
Primary current: 10 A

... material. It has the characteristics of high precision, stable performance, small size, easy installation, and no rust at the opening. It is suitable for measuring and monitoring parameters such as voltage, current, power, and power factor, ...

See the other products
IVY METERING
current transformer
current transformer
VY-CT-OC-36-20

Primary voltage: 3 kV
Primary current: 500 A
Frequency: 50, 60 Hz

... The split core current transformer (CT) uses high-quality ferrite as the magnetic conductive material, which has the characteristics of opening and closing, small magnetic circuit loss, and high magnetic field density. ...

See the other products
IVY METERING
current transformer
current transformer
IVY-CT-OC-34-16

Primary voltage: 3 kV
Primary current: 100, 200, 500 A
Frequency: 50, 60 Hz

... The split core current transformer (CT) uses high-quality ferrite as the magnetic conductive material, which has the characteristics of opening and closing, small magnetic circuit loss, and high magnetic field density. ...

See the other products
IVY METERING
split-core transformer
split-core transformer
SPCM24100X05

Primary voltage: 720 V
Primary current: 100 A
Secondary current: 5 A

... SPCM24 100/5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open and particularly ...

See the other products
ZELEC
split-core transformer
split-core transformer
SPCM24150X05

Primary voltage: 720 V
Primary current: 150 A
Secondary current: 5 A

... SPCM24 150/5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open and particularly ...

See the other products
ZELEC
split-core transformer
split-core transformer
SPCM24200X05

Primary voltage: 720 V
Primary current: 5 A
Secondary current: 200 A

... SPCM24 200/5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open and particularly ...

See the other products
ZELEC
current transformer
current transformer
MSC-TCO series

Primary current: 5 A - 600 A

... closed current transformers combine precision with ease of integration: - **Electrical:** Measure current up to 600A, with an accuracy of 0.5%. - **Physical:** 4 housing sizes according to the measured current range, with an opening ...

See the other products
Lettel
current transformer
current transformer
MTCO-16 series

Primary current: 50, 100 A
Secondary current: 5 A

... The MTCO current transformers combine precision with ease of integration: - Electrical: Primary current from 50 to 100A depending on models. Secondary 1A Accuracy class 1. - Physical: Cable opening Ø16 mm. Housing ...

See the other products
Lettel
current transformer
current transformer
MTCO-36 series

Primary current: 400 A - 600 A
Secondary current: 5 A

... The MTCO split-core current transformers combine accuracy with ease of integration: - **Electrical:** - Transformers for primary current from 400 to 600A depending on models. - Secondary 5A - Accuracy class 1. - ...

See the other products
Lettel
distribution transformer
distribution transformer
TCB-A

Primary current: 500 A - 6,000 A

... The TCB-A is a series of current transformers that are specially made for applications that involve power centers and distribution boards for plant expansion or maintenance. The primary bar does not need to be disconnected because ...

current transformer
current transformer
M53Q series

Primary voltage: 50 V - 300 V
Secondary voltage: 5 V

... Ebony Series Measuring and Protection The range of Crompton Instruments Ebony current transformers offers wide system current ratings, apertures, busbar and case sizes to suit every application. Manufactured to meet EN 60044 the range ...

current transformer
current transformer
SCT027H

Primary current: 160 A

... Characteristics:Hand hold type, leading wire output, audio plug connector(or customized), transient voltage suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor. ...

See the other products
YHDC Dechang Electric
current transformer
current transformer
TQ10

Primary current: 60, 50 A
Secondary current: 1, 5 A
Frequency: 50, 60 Hz

... any supply interruption. Dimensions in mm : 29 x 41 x 26 Round conductor : ⌀ 10 mm The TQ10 is a miniature current transformer. It has the characteristics of small size, light weight, and easy installation. Rated current output ...

See the other products
CELSA MESSGERATE ESPAÑA S.L.
current transformer
current transformer
XH-SCT-T10

Secondary voltage: 0 V - 3 V
Primary current: 0 A - 80 A
Secondary current: 0 A - 0.8 A

... XH-SCT-T10 Split Core Current Transformer CTs Specifications: 1.Diameter:10mm 2.Rated current:0-80A 3.Rated output:mA or mV(0.333V) 4.Insulation Voltage:3KV 5.Rated Frequency:50HZ/60HZ 6.Operating Temperature:-15℃to 60℃ 7.Flame ...

See the other products
Jiangyin Spark Electronic Technology Co.,LTD
current transformer
current transformer
CTS-TU Series

Secondary voltage: 333, 100 mV
Primary current: 5 A - 600 A
Secondary current: 40, 100 mA

... Split Core Type Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • Dielectric Strength : 2.5kV/1mA/1min Mechanical ...

See the other products
Rayfull Electric Technology(Zhejiang)Co., Ltd.
current transformer
current transformer
IJCT-24-1

Primary current: 40 A - 80 A

... Impulse Withstand Voltage: 5KV Peak Insulation Resistance: DC500V/100MΩ min Opening Angle: 180 degree ...

current transformer
current transformer
HF

... When a current transformer is used instead of a quadrupole, the current transformer can be placed around a coupling capacitor terminal or around a part of the test object itself. A current transformer ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us
DirectIndustry RFQ: Free quotation comparison tool
Receive and compare quotations for free
Describe your project
We select
the best suppliers
Compare quotations and complete your purchase