- Electricity - Electronics >
- Energy: Production and Distribution >
- Industrial transformer
Industrial transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Output power kVA: 0.025 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24, 230, 115 V
Safety and circuit separation transformers from 25 to 2500 VA Universal range 25 VA to 2500 VA - Double winding Fixing on omega rail (depending on model) or panel (screw) Secondary earthing by plug-in jumpers (depending ...

Output power kVA: 0.105, 210 kVA
Primary voltage: 115, 230 V
Secondary voltage: 24 V
The Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10024 transforms AC line voltage into short circuit ...

Output power kVA: 0.105 kVA
Primary voltage: 115 V - 230 V
Secondary voltage: 12, 24 V
The Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10012 transforms AC line voltage into short circuit ...

Electric power: 1 W - 1,000,000 W
Primary voltage: 20 kV - 400 kV
Secondary voltage: 410 V - 90,000 V
For step-up power transformers, as for wind farm production transformers, we pay particular attention to reducing the transformer’s noise level, as well as ensuring very low load and ...

Electric power: 100 W - 3,150 W
Primary voltage: 20 kV
Secondary voltage: 410 V
... . Trafo ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC standard, to guarantee an optimised life of the dry-type transformer. Description The ...

Electric power: 1 W - 100,000 W
Primary voltage: 1 kV - 63 kV
Secondary voltage: 120 V - 52,000 V
... ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC normative requirements, to guarantee an optimised lifetime of the dry-type transformer. Description The ...

Primary current: 0 A - 1,800 A
CT 80II, a much smaller and lighter current transformer, developed by Fanox, reaches up to 1800 A of primary current and has a transformers ratio of 1200/5. The product includes a sealable ...

Primary current: 0 A - 1,800 A
... Measurement Transformer for remote management in Low Voltage Open-core Current Transformers– CT80II ABR Open core current transformers don´t need shutdown ...

... Core Current Transformer – CT80 ABR Electric Energy Measurement Transformer for remote management in Low Voltage Open-core current transformers that facilitate assembly without ...

Primary voltage: 24, 230 V
Secondary voltage: 0 V - 10 V
Primary current: 5 A - 5,000 A
SOCOMEC current transformers provide a standard current to the secondary proportional to the primary current, which is adapted to the related device's rating. Standard version features detachable terminal covers and double ...

High-frequency current transformer for medium-voltage power cables The MCT 085 high-frequency current transformer (HFCT) is specifically designed for offline or online partial discharge (PD) measurement ...

Frequency: 47 Hz - 450 Hz
Split Core Toroidal Transformer Ø160 for Type A-F Earth Leakage Relays
FRER

Frequency: 47 Hz - 450 Hz
Toroidal Transformer Ø35 for Type A-F Earth Leakage Relays
FRER

Frequency: 47 Hz - 450 Hz
Toroidal Transformer Ø160 for Type A-F Earth Leakage Relays
FRER

... optimal for our products as we take pride in being the first company in the world to commercialize ferrite. We develop transformers for AC/DC converters that maximize this feature. They are also compatible with flyback ...

Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
• IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • ...
Dowei Electric

Output power kVA: 630 kVA - 63,000 kVA
Primary voltage: 66 kV
• IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • ...
Dowei Electric

Output power kVA: 31,500 kVA - 300,000 kVA
Primary voltage: 220 kV
• IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • ...
Dowei Electric

Output power kVA: 0 kVA - 2,500 kVA
Primary voltage: 10, 35 kV
... water-cooled dry-type transformer Scope of application: All series of products are suitable for 10kV and 35kV power transmission and distribution systems, and can be used for power and lighting in residential areas, ...

Output power kVA: 30 kVA - 2,500 kVA
Primary voltage: 10, 20, 35 kV
... streets, industrial and mining enterprises, and rural areas. The low voltage coil of the transformer is wound with copper foil or semi-hard copper wire, which enhances the ability of the transformer ...

Output power kVA: 28 kW - 824.6 kW
Primary voltage: 220, 110 kV
... non-excitation voltage-regulating transformers, on-load voltage-regulating transformers and autotransformers. Product application: power plants, substations, large industrial and mining ...

Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
TT transformers are used for insulation galvanic three-phase installations for reasons of security. They are also used in the generation of neutrals referenced to ground in single-phase installations of high power. Dry ...
POLYLUX

Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
... the TT transformers help improve the quality of the signal that feeds the charges. • On the other hand in facilities where there may be several leakage to ground, TT transformers ensure the supply avoiding ...
POLYLUX

Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
TT transformers are used for insulation galvanic three-phase installations for reasons of security. They are also used in the generation of neutrals referenced to ground in single-phase installations of high power. Dry ...
POLYLUX

Primary voltage: 33 kV - 35 kV
Secondary voltage: 0 V - 800 V
Product Overview: Oil-immersed transformers for agricultural irrigation are durable outdoors, have strong anti-interference ability, and are cost-effective, facilitating farmland water conservancy. Specific Introduction: i.Outdoor ...
LUSHAN CHINA

Output power kVA: 1.5 kVA
Primary voltage: 3,300 V
Secondary voltage: 1,140 V
Product Overview: This single-phase transformer for HV test gear does crucial HV isolation. It segregates circuits, ensuring safety and operation, vital for precise HV testing. Specific Introduction: 1. Top-notch ...
LUSHAN CHINA

Output power kVA: 3.6 W
Primary voltage: 12 V
Secondary voltage: 24 V
Product Overview: Pulse transformers for electronic instruments have accurate waveform restoration and good noise suppression, facilitating precise measurement. Specific Introduction: i.Accurate Waveform Reproduction: ...
LUSHAN CHINA

Primary voltage: 720 V
Primary current: 5 A
Secondary current: 5, 1 A
... primary wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer ...
ZELEC

Primary voltage: 720 V
Primary current: 10 A
Secondary current: 1, 5 A
... primary wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer ...
ZELEC

Primary voltage: 720 V
Primary current: 15 A
Secondary current: 5, 1 A
... primary wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer ...
ZELEC

Output power kVA: 0.00125 kVA - 0.045 kVA
Secondary voltage: 720 V
Primary current: 60 A - 1,000 A
• Transformer core can be easily divided • excellent for retrofitting, as the primary circuit does not have to be interrupted • simple and secure attachment to busbar - audible latching of current transformer ...
Celsa Messgeräte GmbH

Primary current: 50 A - 500 A
Secondary current: 1, 5 A
Frequency: 50 Hz - 60 Hz
Dimensions: 44 x 66 x 30 mm Round conductor: Ø 21 mm General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with ...
CELSA MESSGERATE ESPAÑA S.L.

Primary current: 50 A - 500 A
Secondary current: 1, 5 A
Frequency: 50 Hz - 60 Hz
Dimensions: 60 x 80 x 30 mm Round conductor: Ø 21 mm General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with ...
CELSA MESSGERATE ESPAÑA S.L.

Primary current: 50 A - 300 A
Secondary current: 5 A
Frequency: 50 Hz - 60 Hz
Dimensions - 50 x 70 x 34 mm Primary bar - 20 x 10 mm General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated secondary terminals with ...
CELSA MESSGERATE ESPAÑA S.L.

Electric power: 160,000 W
Primary voltage: 400 V
Secondary voltage: 480 V
Split- winding transformer Split-winding transformer separate the low voltage winding into 2 isolated parts, each winding can work individually or together. The advantage of the transformer. 1)Reduce ...

Electric power: 1,000 W - 1,000,000 W
Primary voltage: 220 V - 660 V
Secondary voltage: 5 V - 600 V
... loads generate harmonic currents that cause transformers and system neutrals to overheat, which can destroy the transformer. When a non-linear load is supplied from a transformer, ...

Electric power: 0.16 W
Primary voltage: 110 V - 480 V
Secondary voltage: 20 V - 380 V
Control Transformers, Power Isolation transformer DKC 160VA Single Phase Industrial Control Transformers provide stepped-down voltages to machine tool control devices ...

Output power kVA: 0.005 kVA
Primary voltage: 120 V
Secondary voltage: 12 V
Input Voltage: 120V AC Output Voltage: 12V AC Rated Power: 50VA Core Material: High Permeability Silicon Steel Dimensions: Inner Diameter (I.D.): 70 mm - Outer Diameter (O.D.): 90 mm, Height: 20 mm

Output power kVA: 0.3 kVA
Primary voltage: 220 V
Secondary voltage: 12 V
Our 300VA Toroidal Transformer is the ideal solution for your power supply needs. With an output of 12V AC and a power rating of 300VA, this transformer offers reliable and stable performance in a compact ...

Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl

Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl

Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
Tesar Srl

Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
The single-phase and three-phase transformers and auto-transformers are equipped with either copper or aluminum windings. These units feature air-type cooling and can perform up to 2000 kVA, with a frequency ...

Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to 2000 kVA Frequency: ...

Output power kVA: 0.72 kVA
Primary current: 50 A - 300 A
Secondary current: 1 A - 5 A
Solid core Current transformer 100A/1A Specifications Rated primary current 100 A Output 1 A Hole diameter 24 mm (0.94 in) Accuracy class
CARLO GAVAZZI

Electric power: 50, 75, 37.5 kVA
Primary voltage: 240, 480 V
Secondary voltage: 120, 240 V
Non-Ventilated Transformers - 240 x 480 Primary Volts - 120/240 Secondary Volts - Four Windings - 1Ø, 60Hz
Acme Electric

Output power kVA: 1.5 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
... hand. The transformer is encased in GRP (glass fibre-reinforced polyester), is easy to carry and is fitted with a 16 A Schuko plug for your connection. This type of safety site transformer is commonly ...
RS PRO

Electric power: 52,000,000 W
Primary voltage: 0 V - 52,000 V
Wherever distribution transformers have to assure the utmost safety in areas frequented by people, GEAFOL® cast-resin transformers are the ideal solution. With GEAFOL, the limitations of liquid-filled ...

Output power kVA: 1,200 kVA
... medium and small power transformers include equipment and solutions tailored to meet global customer’s needs. GE utilizes the latest in design, measurement and testing tools to ensure each transformer ...
GE Grid Solutions

Output power kVA: 405,200, 700,000, 1,000,000, 3,000, 1,500,000 kVA
Primary voltage: 1,000 kV
Secondary voltage: 800, 66, 500, 750, 1,000 kV
... featured in the performance of high reliability, low loss, low noise, low temperature rise, low partial discharge etc. The transformer is built into the wind generator nacelle, which can realize the local voltage boost ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining