- Electricity - Electronics >
- Energy: Production and Distribution >
- Outdoor service transformer
Outdoor service transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 7,500 kVA
... GE Prolec’s distribution transformers are designed for the diverse mining, oil and gas and distribution markets of North America and international applications. Our distribution substation transformers are suited for ...
Primary voltage: 36 kV - 800 kV
Primary current: 4,000 A
... customer-tailored solutions IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators. Hitachi Energy current transformers are tailor-made. ...
Hitachi Energy
Primary voltage: 11 kV - 33 kV
... CG presents dry type MV current and voltage transformers. CG started making polycrete CTs & VTs in 1994-95. In the year 1995, it patented polycrete application for electrical appliances. From that time, it has manufactured over 50000 ...
Electric power: 1 W - 1,000,000 W
Primary voltage: 20 kV - 400 kV
Secondary voltage: 410 V - 90,000 V
... For step-up power transformers, as for wind farm production transformers, we pay particular attention to reducing the transformer’s noise level, as well as ensuring very low load and no-load losses. We ...
Electric power: 1 W - 100,000 W
Primary voltage: 1 kV - 63 kV
Secondary voltage: 120 V - 52,000 V
... ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC normative requirements, to guarantee an optimised lifetime of the dry-type transformer. Description The ...
Output power kVA: 50 kVA - 2,500 kVA
Primary voltage: 10 kV
Secondary voltage: 0.4 kV
... Oil-immersed Transformer Our oil-immersed transformers are perfect for transforming voltage, commonly from 10kv or 35kv down to 380V or 220V for end-user applications. Suitable for both indoor and outdoor ...
Ximai Electric (Wuhan) Co.,Ltd
Output power kVA: 3.75 W - 15 W
Primary voltage: 10 kV
Primary current: 50 A - 1,000 A
... Product Details
This inverted current
transformer is designed for 10kV
outdoor applications, featuring composite insulation materials for all-weather protection. The unique inverted design lowers the ...
Ximai Electric (Wuhan) Co.,Ltd
Output power kVA: 0.01 kVA
Primary voltage: 10 kV
Primary current: 5 A - 1,000 A
... This outdoor current transformer is an epoxy resin full enclosed pillar product. It is used for electric energy metering, current metering and relay protection. This CT meets the standard of IEC185 and GB1208-2006 . It ...
Ximai Electric (Wuhan) Co.,Ltd
Primary current: 5 A - 100 A
Frequency: 50, 60 Hz
... The split core current transformer (CT) uses high-quality ferrite as the magnetic conductive material, which has the characteristics of opening and closing, small magnetic circuit loss, and high magnetic field density. Small size, stable ...
Output power kVA: 50 kVA - 3,150 kVA
Primary voltage: 33 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural ...
Dowei Electric
Output power kVA: 30 kVA - 1,600 kVA
Primary voltage: 12 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • High magnetic susceptibility, Low coercivity • Low loss and Low magnetizing current, Higher stability • Seismic design, ...
Dowei Electric
Output power kVA: 75 kVA - 5,000 kVA
Primary voltage: 15 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude ...
Dowei Electric
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
... Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to 2000 kVA Frequency: up to 1000 Hz Phases: ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 Transformers ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
... Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection interface • ...
Tesar Srl
Primary voltage: 0 V - 72,500 V
Secondary voltage: 0 V - 200,000 V
... TTR cast resin transformers are distribution, industrial and power transformers with ratings up to 30 MVA. Medium voltage windings are vacuum casted with epoxy resin and they are suitable for indoor or outdoor ...
Electric power: 30 W - 1,600 W
Secondary voltage: 30 V - 900 V
... PSK & PZT AC test transformers are especially designed for testing objects of medium capacitance in the factory, indoor or outdoor. PSK & PZT test systems are particularly suited for tests requiring stable voltage ...
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
... small peaks of voltage or noise, the TT transformers help improve the quality of the signal that feeds the charges. On the other hand in facilities where there may be several leakage to ground, TT transformers ensure ...
Primary voltage: 33, 36 kV
Secondary voltage: 100 V - 240 V
Frequency: 50, 60 Hz
... Installation: outdoor Highest voltage for equipment Um (r.m.s.) 12 up to 36kV Rated power-frequency withstand (induced) voltage (r.m.s.): 75kV Rated lightning impulse withstand voltage (peak): 175kV Rated frequency: 50Hz or 60Hz Applied ...
Pomanique Electric
Output power kVA: 400 kVA
Primary voltage: 380 kV
Secondary voltage: 44 V
... the stable operation of the transformer under rated working conditions. It is often used in high-temperature environments or places with large load fluctuations. 2.Stable Operation: In complex conditions, the transformer, ...
Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Frequency: 60, 50 Hz
... SummarThe 35kV transformer, the use of company-specific calculation and verification procedures, the transformer core, coils, active part, leading tanks and other components for a full range of optimized design and verification, ...
Secondary voltage: 1, 5 V
Primary current: 1, 5 A
... LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of ...
BEIJING GFUVE ELECTRONICS CO.,LTD.
Primary current: 100 A - 1,500 A
Secondary current: 5, 1 A
Frequency: 50 Hz - 60 Hz
... Dimensions: 84 x 108 x 30 mm Round conductor: Ø 42 mm Primary bar: 50 x 13 mm 2 x 10 x 10 mm General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • nickel-plated ...
CELSA MESSGERATE ESPAÑA S.L.
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 5 A
... IP67 FSCT-T36 Outdoor Waterproof Split Core Current Transformer SPECIFICATIONS: 1.Rated current:0-600A 2.Rated output:5A or 1A 2.Insulation Voltage:3KV 3.Rated Frequency:50HZ/60HZ 4.Operating Temperature:-15℃to ...
Jiangyin Spark Electronic Technology Co.,LTD
Primary voltage: 24 kV - 170 kV
Primary current: 5,000 A
Frequency: 16.7, 50, 60 Hz
... combined instrument transformer is similar to the construction of the current and voltage transformer. The current transformer is located in the head and the voltage transformer in the ...
Electric power: 6,120,000 W
Output power kVA: 0 kVA - 7,650 kVA
Primary voltage: 70 kV
... provides highly performing LV /MV three phase oil-insulated type transformers. Power ratings are available upto 7,650 kVA, with voltage ratings (MVside) from 10 up to 38 kV.The transformers are classified as perthe IEC ...
Output power kVA: 0.06, 0.02, 0.03 kVA
Secondary voltage: 140, 180, 225 kV
Primary current: 50 A - 1,200 A
... cycloaliphatic epoxy resin, this high-voltage (72 kV) outdoor-type current transformer is designed to withstand solar ultraviolet radiation and IEC-defined pollution level III (“Heavy”). This HV current transformer ...
CHALLENGE INDUSTRIAL CO., Ltd
Output power kVA: 4,000 kVA - 200,000 kVA
Primary voltage: 11 kV - 220 kV
Secondary voltage: 3.3 kV - 132 kV
... Power Transformers (Up to 200MVA) Any transformers with higher ratings than the standard distribution transformers (more than 4000kVA and up to 200MVA) can be built as a power transformer ...
Electric power: 30 W - 30,000 W
Primary voltage: 230, 400 V
Secondary voltage: 48, 12, 24 V
... Compliant with standard EN 61558-2-6 • Standard voltages • Other voltages available on request • Electrostatic screen available on request • Ambient temperature 40 °C • Protection rating IP00 • Electrical protection rating I • Thermal insulation ...
Electric power: 0.0013 kVA - 0.03 kVA
Primary current: 5, 1 A
... Our manufacturing program also includes supporting type current transformers for outdoor installation. The resin is cycloaliphatic and outdoor proof. Because it is vacuum impregnated and cured under ...
TWB SA
Electric power: 30 W - 31,500 W
Primary voltage: 6,000 V - 38,500 V
Secondary voltage: 400 V - 11,000 V
... Range of use: S11-M series of Henre transformer can be widely used in high-rise buildings, commercial center, subway, airport, station, industrial and mining enterprises, oil drilling platform, platform, particularly applicable to flammable, ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group