Lightguards Type2
OPT2 P18 PIAT
Detection 18mm-Finger
Protected Height 106 ÷ 319mm
Range HP ÷ 4 Meters
2 Switches Output-ON/OFF
Housing 20x30mm
OPT2 SMC P18
Detection 18mm-Finger
Protected Height 175 ÷ 315mm
Range HP ÷ 16 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
OPT2 P18 penta
Detection 18mm-Finger
Protected Height 105 ÷ 573mm
Range HP ÷ 16 Meters
2 Switches Output-ON/OFF
Housing 45 x 45mm
OPT2 SMC P40
Detection 40mm-Hand
Protected Height 240 ÷ 1840mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
BO/RM S40
Detection 40mm-Hand
Protected Height 400 ÷ 1280mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 45 x 45mm
OPT2 SMC P80
Detection 80 mm -Arm
Protected Height 400 ÷ 2320mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
OPT2 SMC P120
Detection 120 mm -Body
Protected Height 560 ÷ 3680mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
BO/RM S120
Detection 120 mm -Body
Protected Height 480 ÷ 1440mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 45 x 45mm
OPT2 SMC P240
Detection 240 mm - Body
Protected Height 1850 ÷ 2810mm
Range HP ÷ 30 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
OPT2 SMC P280
Detection 280mm - Access
Protected Height 560mm
Range HP ÷ 70 Meters
2 Switches Output-ON/OFF
Housing 22 x 36mm
|
|
The SB2-K-2-500 safety barriers has been developed for applications which require the detection of the human body; it is a low resolution system with 2 beams placed with an optic interaxis of 500 mm. The optic interaxis is compliant to the requirements of the EN 999 Regulation.
It is possible to realise barriers with height and number of beams changeable, according to the specific uses and requirements. Thanks to the small size, the easiness of installation and the high performances, the product is extremely versatile. The control and command electronics are inside the barrier; connections are made through a connector positioned under the barrier. No connection is necessary between the emitter and receiver, thanks to the optical type synchronism. The control of the emitted and received beams is guided by the two microprocessors that, by means of signalling LEDs, also supply information on the barrier's operating status. The installation is facilitated thanks to two alignment LEDs.
|
|
Safe4 light curtain is a contactless safety device with built-in self-testing. It contains two redundant self-monitored chan nels which fulfill index IV of the Machine Directive EC/98/37 as cat. 4 safety light curtains and IEC / EN 61496.
The light curtain system is very resistant to ambient light interference and can cope easily and very reliably with demanding applications, such as welding robots. The large detection range (up to 30 m for hand-resolution and up to 9 m for finger-resolution) also enables the reliable safeguarding of hazardous zones covering large areas. With Safe4 units available starting at 120 mm lengths, they are optimally designed to safeguard small hazardous areas.In addition, it is also possible to combine multiple protective fields (cascading or L-configuration), and monitor them with a single controller. This provides the machine manufacturer the freedom to optimize the machine design.
|
|
Safety Light Curtains - Type SLC-F
Partial or Total Muting Override Manual or Auto reset Easy alignment using 2 LED's - Upper and Lower Compact dimensions - easy to install M12 connector outputs
|
|
|
|
|
|
|
Leuze lumiflex has extended its delivery range of safety sensor technology with the integrated PROFIsafe interface. In addition to the type 3 safety laser scanner, RS4-4/PROFIsafe, a type 4 safety light curtain with integrated PROFIsafe interface is now also available with the COMPACTplus/PROFIsafe. The PROIBUS DP bus activation is performed here directly and without additional bus coupling modules. With a data transfer rate of up to 12 MBd, both the safe cyclic and the acyclic data traffic are supported on the PROFIBUS DP. Rapid safety-relevant real-time data, such as a switch-off command when operating the sensor and comprehensive diagnostics data with the controlling PLC, for example, can consequently be exchanged. COMPACTplus/PROFIsafe meets the requirements of SIL 3 in accordance with IEC 61508 and is available with the blanking, muting and cycle control function packages. The individual adjustment of the functions is performed via the optical PC interface of the receiver with “teach-in” and with the aid of the convenient diagnostics and parametering software, SafetyLab.
|
|
|
|
|
|
OPTOELECTRONIC SAFETY BARRIERS TYPE 4
Optoelectronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines. The safety barrier Admiral AX, with its two safe static outputs, can work without external control units with all the safety functions integrated inside the Emitter and the Receiver complying perfectly with the requirments of the European Standard EN 61496-1 and the International Standard IEC 61496-1-2. The Admiral AX integrates the start/restart interlock function as well as the External Device Monitoring (EDM). Master/Slave.
Conforming to:
- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery - Electro-sensitive protective equipment- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment – Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.
|
|
|
|
|
|
OPTOELECTRONIC SAFETY BARRIERS TYPE 4
Optoelectronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines, in situation where the MUTING function is necessary.
The Safety Barrier Janus, with its two safe static outputs, can work without external control units having all the safety functions integrated inside the Emitter and the Receiver and complying perfectly with the requirements of the European Standard EN 61496-1 and of the International Standard IEC 61496-1-2.
Conforming to:
- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery - Electro-sensitive protective equipment- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment – Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.
|
|
|
|
|
|
SF4B series: Global safety light curtain with muting, Type 4
Just as with the SF4-A series, the SF4B series remains impervious to interference from extraneous light. However, the SF4B series is more compact, includes muting control circuits in the light curtian and an override function that allows a manufacturing line to restart operation after the line has been stopped, even while muting control was active. These functions all contribute to a light curtain that provides greatly improved safety with no loss in productivity. Now also available with new corner mirrors for less work and less wiring. A large reduction in cost!
Characteristics:
More than 40 models for finger, arm or body protection
High-speed response (max. 14ms)
No dead zone; unit height = protective height
OSSD1 and OSSD2 NPN/PNP switchable
Muting integrated
Fixed and floating blanking
Display with error code
Series connection
Mutual interference prevention (ELCA)
Override
Accessories:
Extension cables
External relay unit
Cables for series connection
Mounting brackets
Slit masks
Corner mirrors
|
|
Lightguard Type4
ODS2 RC P36
Detection 36mm Hand
Protected Height 215 ÷ 2200mm
Range HP ÷ 25 Meters
Output 2PNP open collector
Housing section 36 x 36mm
ODS2 RC P72
Detection 72mm Arm
Protected Height 286 ÷ 2339mm
Range HP ÷ 25 Meters
Output 2PNP open collector
Housing section 36 x 36mm
ODS2 RC P108
Detection 108mm Body
Protected Height 625 ÷ 1445mm
Range HP ÷ 30 Meters
Output 2PNP open collector
Housing section 36 x 36mm
ODS2 RC P275
Detection 275mm Access
Protected Height 550mm
Range HP ÷ 50 Meters
Output 2PNP open collector
Housing section 36 x 36mm
|
|
The SB4-K-2-500 safety barriers has been developed for applications which require the detection of the human body; it is a low resolution system with 2 beams placed with an optic interaxis of 500 mm. The optic interaxis is compliant to the requirements of the EN 999 Regulation.
It is possible to realise barriers with height and number of beams changeable, according to the specific uses and requirements. Thanks to the small size, the easiness of installation and the high performances, the product is extremely versatile. The control and command electronics are inside the barrier; connections are made through a connector positioned under the barrier. No connection is necessary between the emitter and receiver, thanks to the optical type synchronism. The control of the emitted and received beams is guided by the two microprocessors that, by means of signalling LEDs, also supply information on the barrier's operating status. The installation is facilitated thanks to two alignment LEDs.
|
|
|
|
|
|
Application:
Optoelectronic safety device are used as entry, danger point or danger zone guards.
SLG/SLC range safety light grids and light curtains can be integrated into the safety concept of the machine or plant even under tight space conditions by virtue of their very compact design.
These safety devices are also often used on presses to guard danger points or zones. Depending on the paticular resolution of the safety light grids and curtains, protection of persons, hands or even fingers can be provided. SLG/SLC range safety light grids and light curtains achieve Control Category 4 to EN 954-1.
Design and mode of operation:
On the SLB/SLC/SLG ranges of optoelectronic safety devices, the emitter and receiver are fitted in two separate enclosures. An invisible infra-red signal is sent from the emitter and this is picked up by the lens system of the receiver and evaluated either by an integral or external safety monitoring module. If the light beam is interrupted, the secure outputs are switched.
All of the optoelectronic safety devices listed here are maintenance-free and are characterised by simple fitting and adjustment.
|
|
Application:
Optoelectronic safety device are used as entry, danger point or danger zone guards.
SLB range safety light barriers ar utilised as entry guards to dangerous areas. these protection devices operating without physical contact achieve Control Category 2 or 4 to EN 954-1 in combination with SLB 200-C or SLB 400-C safety monitoring modules.
Design and mode of operation:
On the SLB/SLC/SLG ranges of optoelectronic safety devices, the emitter and receiver are fitted in two separate enclosures. An invisible infra-red signal is sent from the emitter and this is picked up by the lens system of the receiver and evaluated either by an integral or external safety monitoring module. If the light beam is interrupted, the secure outputs are switched.
All of the optoelectronic safety devices listed here are maintenance-free and are characterised by simple fitting and adjustment.
|
|
|
The Optex OS-12C active infrared safety beam system is compatible with any type of automaic door. Its amplifier and sensor head are designed for fast, simple installation while maintaining the highest standards of safety and reliability
|
|
|
SICK's single-beam photoelectric safety switches consist either of testable senders and receivers, or of testable senders and receivers combined with an evaluation unit. These devices impress both with their large scanning range and the variety of shapes and sizes available. They also offer maximum safety performance as they comply with type 2 or type 4 in accordance with EN 61496 and PL c or PL e according to EN ISO 13849. The possible applications are very wide-ranging: Whether on robots, processing machines, machining centres, palletising systems, high-bay warehouses or transfer lines - with products from SICK you will profit from a customer-friendly solution of the highest quality.
|
|
|
|
|
|
OPTOELECTRONIC SAFETY LIGHT CURTAINS TYPE 4 WITH BLANKING FUNCTION
Optoelectronic Safety Light Curtain for the protection of workers exposed to risks arising from the use of dangerous machines.
Admiral AX BK integrates the Blanking function.
Conforming to:
- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery - Electro-sensitive protective equipment- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment - Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.
|
|
| ... products without technical information |
| |
|
|