The Loss of Mains Relay type LMR-111D is for protection of the generator against damage resulting from a non-synchronised reconnection to the grid after a temporary mains failure.
Features include
> Detection of vector shift
> Mains disconnection on mains failure
> Ensures no asynchronous reconnection
> LED indication of fault condition
> LED indication for activated relay
> 35 mm DIN rail or base-mounting
The Loss of Mains Relay type LMR-111D forms part of a complete DEIF series of relays for protection and control generators
|
|
|
|
|
|
AGC – the true meaning of multi mains
The updated AGC Automatic Gen-set Controller handles an astonishing 56 breakers and is immune to a failing master controller due to the integrated multi-master principle. Combined with an exhaustive list of other new features, it will simply enable you to do things you would have never thought possible.
Up to 16 mains incoming, 16 mains breakers, 16 tie breakers, 8 bus tie breakers, 16 generators and 16 generator breakers; if this fits the description of your application, you might want to continue reading.
All 56 breakers can be synchronised and communication between the controllers will be fully redundant – all by choice and without extra cost. Moreover, the AGC offers selectable mains priority and parallel operation.
Applications
The AGC supports a vast number of different applications for single gen-set, multiple gen-set and multiple mains. For all of these applications, the AGC supports a number of different plant modes:
> Automatic mains failure/ATS
> Island operation
> Fixed power/base load
> Peak shaving
> Load take over
> Mains power export
|
|
G59 protection relay package
The mains decoupling relay - type G59 package – forms part of a complete DEIF series of relays for the protection and control of generators. This package is applied for the protection of synchronous generators, running in parallel with the mains.
Features include:
- Combined vector shift and ROCOF (df/dt)
- Protection of over-/underfrequency
- 3-phase protection of over-/undervoltage
- Digital data processing
- Fast decoupling of the generator
- Ensures no asynchronous reconnection
|
|
|
|
|
|
he Summarize Measurement and Protection Unit (SMPR-1) has been designed to measure the line and ground RMS currents and supply RMS voltages under normal conditions or under disturbances. The voltage and current signals are sensed throughout potential transformers (PT) and current transformers (CT) from each line. This information is internally processed by the microprocessor, to take the current protection actions defined under ANSI, IAC or IEC standard. Additionally the operational conditions of the breaker or disconnector are also signalized. The different functions provided by the SMPR-1 may be classified into the following groups:
Applications:
* Primary and backup protection for power plants, utility and industrial distribution systems.
* Protection of transformers, overhead lines, cables and generators.
* Permits the opening of the switch/disconnector within the limits of its capacity, those identifying the excess (e.g. straight short-circuits), leaving the circuit interruption to the back-up fuses.
|
|
G60 Generator Protection System
The G60 Generator Management Relay, part of the UR family of protective relays, is a microprocessor-based relay intended for the protection of AC generators. It may be used on any size of generator driven by steam, gas and hydraulic turbine.
Protection functions include stator differential, 3rd harmonic stator ground differential and 3rd harmonic neutral undervoltage for 100% stator ground differential protection, sensitive directional power for low forward power and reverse power protection, loss of excitation, inadvertent energization, overexcitation, current unbalance, out-of-step, and a whole suite of under- and overvoltage, and overcurrent functions.
|
|
|
|
|
|
The 7SD60 relay is a numerical current differential protection relay, simple to set, operating in conjunction with the remote station via a two pilot-wire link. It is connected to the primary current transformers via an external summation current transformer. The primary field of application of the relay is protection of short overhead lines and cables with two line ends. However, transformers and reactors may be located within the protection zone.
Function overview
• Current differential protection with external summation current transformer 4AM49
• Suitable for use for distances of 12 km max. via two pilot-wires
• Differential protection can be combined with overcurrent release
• Pilot-wire monitoring function
• Bidirectional remote tripping
• Circuit-breaker intertripping at the remote station
• Seal-in of the TRIP command until manual reset (Lockout function)
• Minimal current transformer requirements due to integrated saturation detector
• Restraint against inrush / undelayed trip for high differential fault currents
• Emergency overcurrent protection
Operational measured values
• Local and remote current
• Differential current
• Restraint current
|
|
|
|
|
|
Multi-Differential Relay – MDR-2 – digital speed and accuracy, maximum reliability
The MDR-2 is a differential current relay intended for protection of a generator against internal short circuits (leaking currents). It is based on a 16-bit digital signal processor providing maximum performance and reliability.
Features include
> Response time 50 ms
> 3-phase detection of current on primary and secondary side of the generator
> Active, adjustable compensation of non-balanced current measurements
> Measuring accuracy 1%
> Stress-free configuration and operation via clear and simple menu structure
> DIN-rail or base-mounting with remote mountable display
> Approved according to LR, GL, etc.
All measured and calculated values are shown in clear text and numbers on the large LCD display (allowing significant savings on purchase and wiring of external meters).
Available options include a block (generator + step-up transformer) protection option and a short-circuit and overcurrent protection option.
|
|
|
|
|
|
The SIPROTEC 4 7SA522 is a distance protection relay for transmission lines. This relay provides full-scheme distance protection and incorporates all functions usually required for the protection of a power line. The relay is designed to provide fast and selective fault clearance on transmission and subtransmission cables and overhead lines with or without series capacitor compensation. The power system star point can be solid or resistance grounded (earthed), resonant-earthed via Peterson coil or isolated. The 7SA522 is suitable for single-pole and three-pole tripping applications with and without tele (pilot) protection schemes.
The 7SA522 incorporates several protective functions usually required for transmission line protection.
• High-speed tripping time
• Suitable for cables and overhead lines with or without series capacitor compensation
• Self-setting power swing detection for frequencies up to 7 Hz
• Digital relay-to-relay communication for two and three terminal topologies
• Adaptive auto-reclosure (ADT)
One of the communication interfaces is system interface for connecting to a control system via IEC 61850 Ethernet protocol.
|
|
RGU-10 / CBS-4 Family. Inteligent protection
RGU-10
-Instant current leakage and pre-alarm display
- Type A super-immunized earth-leakage protection, suitable for the new industrial environment
- High frequency current filtering
- Programmable sensitivity and delay times
- Small size. Just 3 modules
- Integration into the energy control system of the installation, using RS-485 communications
- Option for earth-leakage reclosing and overload/short circuit protection
CBS-4
- 4 RGU-10 in one single equipment
- Small size. Just 3 modules
- Reduces occupied space and wiring time
|
|
The motor protection relay REM 610 is part of the RE_ 610 series of numerical relays for the protection and supervision of utility substations, and industrial switchgear and equipment.
The motor protection relay REM 610 is primary targeted at protecting large asynchronous low-voltage motors and small and medium-sized high-voltage asynchronous motors. REM 610 handles electrical fault conditions during motor start up, normal operation, idling, and cooling down at standstill, e.g. in pump, fan, mill or crusher applications. The relay can be used with both circuit-breaker controlled and contactor-controlled drives. REM 610 can also be used for the protection of cables feeders and distribution transformers that require thermal overload protection besides overcurrent, earth-fault and phase unbalance protection.
The numerical motor protection relays support a wide range of standard communication protocols, among them the IEC 61850,
IEC 60870-5-103, Modbus, and Profibus.
|
|
|
|
|
|
REM615 is a dedicated motor protection and control IED perfectly aligned for the protection, control, measurement and supervision of asynchronous motors in manufacturing and process industry. REM615 is a member of ABB’s Relion® product family and a part of its 615 protection and control product series. The 615 series IEDs are characterized by their compactness and withdrawable design. Re-engineered from the ground up, the 615 series has been designed to unleash the full potential of the IEC 61850 standard for communication and interoperability between substation automation devices.
REM615 constitutes main protection for asynchronous motors and their drives in manufacturing and process industry. Typically, the motor IED is used with circuit-breaker or contactor controlled HV motors, and contactor controlled medium sized and large LV motors in a variety of drives, such as pumps and conveyors, crushers and choppers, mixers and agitators, fans and aerators. One standard REM615 configuration is available including all the basic motor protection functions, voltage protection functions and power and energy measurements. Local or remote start/stop control of the motor is also facilitated.
Due to the standard configuration of REM615 for the motor protection, the IED can be rapidly set up and commissioned, once it has been given the application-specific settings.
REM615 genuinely supports the IEC 61850 standard for inter-device communication in substations. It also supports the industry standard Modbus® protocol, and the well-established DNP3 and IEC 60870-5-103 protocols.
|
|
General characteristics:
- Overload protection with thermal memory
- Phase aymmetry and phase sequence protection
- External display module for panel mounting (22 mm)
- Not connected to the motor line (passing through wires).
- Manual reset: when tripping as result of asymmetry or phase failure, the relay could be reset after 2 seconds; should tripping be caused by an overload, the waiting time to reset will be directly proportional to its severity, up to approximately 8 minutes.
- Remote reset: after the waiting time has elapsed by interrupting the auxiliary power supply and reconnecting it again after 3 seconds.
- Mounted on DIN rail EN50022-35.
- UL, cUL listed. Marked CE.
- Maximum terminal section : 2.5 mm2, No. 22-12 AWG.
- Maximum screw torque: 20 Ncm, 1.8 LB-IN.
- Norms: IEC 255-22, IEC 801, EN 50081-2, IEC-255, IEC-947
- Insulation: 2000V - 50Hz - 1min/3kV - 1.2/50 µs.
- Storage temperature: -30°C +70°C.
- Operation temperature / Maximum altitude:
-15°C +60°C / 1000 m.
|
|
|
|
|
|
Fanox offer a motor protection relay, with ATEX certificate (PTB). It is ideal for motor application on explosive atmosphere.
General characteristics:
- Overload protection with thermal memory
- Phase aymmetry and phase sequence protection
- External display module for panel mounting (22 mm)
- Not connected to the motor line (passing through wires).
- Manual reset: when tripping as result of asymmetry or phase failure, the relay could be reset after 2 seconds; should tripping be caused by an overload, the waiting time to reset will be directly proportional to its severity, up to approximately 8 minutes.
- Remote reset: after the waiting time has elapsed by interrupting the auxiliary power supply and reconnecting it again after 3 seconds.
- Mounted on DIN rail EN50022-35.
- UL, cUL listed. Marked CE.
- Maximum terminal section : 2.5 mm2, No. 22-12 AWG.
- Maximum screw torque: 20 Ncm, 1.8 LB-IN.
- Norms: IEC 255-22, IEC 801, EN 50081-2, IEC-255, IEC-947
- Insulation: 2000V - 50Hz - 1min/3kV - 1.2/50 µs.
- Storage temperature: -30°C +70°C.
- Operation temperature / Maximum altitude:
-15°C +60°C / 1000 m.
|
|
|
|
|
|
TIME RELAYS
- Modular version for consumer switchboards DIN mount version
- Plug-in or flush-mount version
- Vast range of functions and time scales
- Reliable time and repeat accuracy.
PROTECTION RELAYS
- Versions: modular and 35mm DIN rail mount
- Minimum and maximum voltage monitoring relays for single and three phase systems, with or without neutral
- Voltage asymmetry, phase sequence and phase loss control relays
- Minimum and maximum current monitoring relays
- Frequency monitoring relay.
LEVEL CONTROL RELAYS
- Level monitoring for electrically conductive liquids
- Modular and plug-in versions
- Adjustable 2.5-200kΩ sensitivity
- Single and three-pole electrodes
- Startup priority change relays.
EARTH LEAKAGE RELAYS
- Modular, flush and internal panel mount version, with or without flag indicator, configurable prealarm indication and fail safe operation
- Versions with automatic toroid connection control
- Choice of supply voltage ranges
- Adjustable fault current I∆n
- Adjustment and choice of tripping range for both fault current and delay time.
|
|
239 Motor Protection Relay
239 Motor Protection Relay
The 239 relay is designed to fully protect three phase AC motors against conditions which can cause damage. In addition to motor protection, the relay has features that can protect associated mechanical equipment, give an alarm before damage results from a process malfunction, diagnose problems after a fault and allow verification of correct relay operation during routine maintenance.
|
|
The market-leading Modular Control System (MCS) offers you more freedom to configure load feeder solutions through 1200 A. MCS load feeder components provide the following control and protection functions:
- Disconnecting means
- Short-circuit protection
- Load switching
- Motor overload protection
- Status indication and signaling
- DeviceNet communications
|
|
|
|
|
|
Designed for medium-sized motors, the enhanced 369 Motor Protection System delivers advanced motor health diagnostics, graphical and data rich fault diagnostics, simple six-step setup & configuration and complete traceability of setting changes, enabling industrial facilities to maximize process up-time and optimize rated motor output.
- Motor Settings Auto-Configurator - automatically generate a complete settings file, eliminating the need to manually program hundreds of individual protection settings
- Enhanced Faceplate (E Option) - Improved LCD display with 40 easily visible characters and increased viewing angle
- Motor Health Report (E Option) - "See" how the motor is operating with comprehensive graphs and tables
- Enhanced Motor Learned Data (E Option) - Capture up to 250 sets of motor starting values to learn the starting characteristics of each motor
- Security / Change History Report (E Option) - Patented Security / Change History Report provides complete traceability of all settings changes
|
|
|
LS overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets.
|
|
|
|
|
|
7SD5 relay provides full scheme differential protection and incorporates all functions usually required for the protection of power lines. It is designed for all power and distribution levels and protects lines with two up to six line ends, to provide high-speed and phase-selective fault clearance.
Application
• Differential protection with phase-segregated measurement
• Sensitive measuring stage for high-resistance faults
• Non-switched distance protection with 6 measuring systems
• High resistance ground (earth)-fault protection for 1 and 3-pole tripping
• Phase-selective intertripping
• Tele (pilot) protection
• Weak-infeed protection
• Fault locator
• Power swing detection/tripping
• 3-stage overcurrent protection
• STUB bus protection
• Switch-onto-fault protection
• Over/undervoltage protection
• Over/underfrequency protection
• Auto-reclosure
• Synchro-check
• Breaker failure protection
• Overload protection
• Lockout function
Digital communication via
• fiber-optic cables
• digital communication networks
• pilot wires or ISDN connections
|
|
The SIPROTEC 4 7UM61 and 7UM62 protection relays can do more than just protect. They also offer numerous additional functions. Be it earth faults, short-circuits, overloads, overvoltage, overfrequency or underfrequency asynchronous conditions, protection relays assure continued operation of power stations. They are compact units which has been specially developed and designed for the protection of small, medium-sized and large generators.
They integrate all the necessary protection functions and are particularly suited for the protection of:
• Hydro and pumped-storage generators
• Co-generation stations
• Private power stations using regenerative energy sources such as wind or biogases
• Diesel generator stations
• Gas-turbine power stations
• Industrial power stations
• Conventional steam power stations.
The combination of functions incorporated in the 7UM62 also offers excellent all-round protection for transformers, large asynchronous motors, synchronous motors.
|
|
The SIPROTEC 7SJ602 is a numerical overcurrent relay which, in addition to its primary use in radial distribution networks and motor protection, can also be employed as backup for feeder, transformer and generator differential protection. It provides definite-time and inverse-time overcurrent protection along with overload and negative-sequence protection for a very comprehensive relay package. In this way, equipment such as motors can be protected against asymmetric and excessive loading.
Feeder protection
• Overcurrent-time protection
• Sensitive earth-fault detection
• Directional sensitive earth-fault detection
• Displacement voltage
• Disk emulation
• Overload protection
• Breaker failure protection
• Negative-sequence protection
• Cold load pickup
• Auto-reclosure
• Trip circuit supervision
Motor protection
• Starting time supervision
• Locked rotor
• Restart inhibit
• Undercurrent monitoring
|
|
The protective overload relay type RMP-111D forms part of a complete DEIF series of relays for protection and control of generators, and is applicable to both marine and land-based installations.
Features include
> Protection of prime mover
> 3-phase measurement
> LED indication of alarm condition
> Timer-controlled tripping
> LED indication for activated relay
> 35 mm DIN rail or base-mounting
The RMP-111D is type-approved by major classification societies and is applied for protection of the prime mover against overload. This is especially required if the prime mover is underdimensioned in proportion to the AC generator.
|
|
SIP 6
The SIP6 series contains extremely powerful 6-pole relays with forcibly guided contacts in accordance with EN 50205 for switching loads up to 16 A. Crown contacts for high switching reliability at the two readback contacts and 4 power contacts up to 16A and 60A surge currents. For the highest loads during 3-phase applications and DC loads.
- Contact mounting: 4NO, as power contacts 1NO / 1NC or 2NC signal contacts
- Switching current range 10 mA to 16 A
- Coil voltage 6 VDC to 220 VDC (non-standard coils available upon request)
- Coil loss power 1.3 W
- Design (LxWxH) 84.6 x 20 x 32 mm
- Approvals: UL, cUL, SEV, TÜV
Areas of application: hydraulic controllers, construction machinery, lifting technology, off-shore applications, door control
|
|
SIR 4 Power
The SIR4P contains extremely powerful, compact 4-pole power relays with forcibly guided contacts in accordance with EN 50205 for switching loads up to 12 A. 2 powerful contacts for loads with a high surge current (up to 60A) in the AC and DC range and 2 checkback contacts.
- Contact mounting 2NO / 2NC or 3NO / 1NC
- Switching current range 10 mA to 12 A
- Coil voltage 6 VDC to 110 VDC (non-standard coils available upon request)
- Coil loss power 0.75 W
- Design (LxWxH) 46.4 x 16 x 30.7 mm
- Approvals: UL, cUL, SEV, TÜV
Areas of application: door controls, motion control, transportation, farm machinery
|
|
|
|
|
|
General characteristics:
- Pump protection (dry working protection) without external sensor
- Overload protection with thermal memory
- Phase aymmetry and phase sequence protection
- External display module for panel mounting (22 mm)
- Not connected to the motor line (passing through wires).
- Manual reset: when tripping as result of asymmetry or phase failure, the relay could be reset after 2 seconds; should tripping be caused by an overload, the waiting time to reset will be directly proportional to its severity, up to approximately 8 minutes.
- Remote reset: after the waiting time has elapsed by interrupting the auxiliary power supply and reconnecting it again after 3 seconds.
- Mounted on DIN rail EN50022-35.
- UL, cUL listed. Marked CE.
- Maximum terminal section : 2.5 mm2, No. 22-12 AWG.
- Maximum screw torque: 20 Ncm, 1.8 LB-IN.
- Norms: IEC 255-22, IEC 801, EN 50081-2, IEC-255, IEC-947
- Insulation: 2000V - 50Hz - 1min/3kV - 1.2/50 µs.
- Storage temperature: -30°C +70°C.
- Operation temperature / Maximum altitude:
-15°C +60°C / 1000 m.
|
|
SIR 8 / SIR 10
The SIR8, SIR10 series contains powerful, compact 8- and 10-pole relays with forcibly guided contacts in accordance with EN 50205 for switching loads up to 10 A. Crown contacts for high switching reliability. Wide coil working ranges.
- Contact mounting 8- resp. 10-pole, free configurable
- Switching current range 10 mA to 10 A
- Coil voltage 6 VDC to 220 VDC (non-standard coils available upon request)
- Coil loss power 1.3 W
- Design (LxWxH) 85.5 x 20 x 32 mm
- Approvals: UL, cUL, SEV, TÜV
Areas of application: lifts, machine tools, farm machinery, transportation, robotics
|
|
SIR 6 / SIR SEN
The SIR6, SIR6 SEN series contains powerful, compact 6-pole relays with forcibly guided contacts in accordance with EN 50205 for switching loads up to 10 A. Crown contacts for high switching reliability. Wide coil working ranges
- Contact mounting 5NO / 1NC, 4NO / 2NC or 3NO / 3NC
- Switching current range 10 mA to 10 A
- Coil voltage 6 VDC to 110 VDC (non-standard coils available upon request)
- Coil loss power 0.5 W or 0.75 W
- Design (LxWxH) 58.9 x 16 x 30.7 mm
- Approvals: UL, cUL, SEV, TÜV
- Manipulation-protected socket for PCB mounting
Areas of application: lifts, machine tools, construction machinery, transportation, robotics
|
|
SIS 2 / SIS 3 / SIS 3 SEN
Very compact SIS2, SIS3 and SIS3 SEN series 2- and 3-pole relays with forcibly guided contacts in accordance with EN 50205. In addition to their very small dimensions, this relay series stands out thanks to its high shock resistance, large exciting voltage range and low coil loss power, as well as its high switching reliability due to its notched crown contact .
- Contact mounting 1NO / 1NC or 2NO / 1NC
- Switching current range 5 mA to 6 A
- Coil voltage 5 VDC to 110 VDC (non-standard coils available upon request)
- Very low coil excitation and retention capacity
- Design (LxWxH) 29.2 x 16.6 x 16.5 mm
- Approvals: UL, cUL, SEV, TÜV
Areas of application: medical technology, sensors, interfaces, transportation, motion control, door control
|
|
SIR4, SIR4 SEN
The SIR4, SIR4 SEN series contains powerful, compact 4-pole relays with forcibly guided contacts in accordance with EN 50205 for switching loads up to 10 A. Crown contacts for high switching reliability. Wide coil working ranges
- Contact mounting 2NO / 2NC or 3NO / 1NC
- Switching current range 10 mA to 10 A
- Coil voltage 6 VDC to 110 VDC (non-standard coils available upon request)
- Coil loss power 0.36 W or 0.6 W
- Design (LxWxH) 46.4 x 16 x 30.7 mm
- Approvals: UL, cUL, SEV, TÜV
- Manipulation-protected socket for PCB mounting
Areas of application: process technology, lifts, machine tools, vehicle construction
|
|
|
|