The precise regulation of the air flow into sewage basins does not only influence the optimal quality of your cleaning process but furthermore still saves pure money because the energy-intensive compressed air is well applied in optimal quantities.
A too low oxygen supply leads to insufficient pollutant reduction and consequently to a reduced cleaning performance. In the worst case, an infringement of the desired limits occurs.
A too generous ventilation doesn’t bring any higher cleaning performance, but the energy costs for useless compressor performance can impair your installation effectiveness quite considerably.
Deltafit secures optimum oxygen input to your prozess, saves pure energy costs, works also under heaviest conditions for years without any maintenance – and fault-free. The optimally adapted components are prooving their precision and reliability in thousands of industrial installations in the entire process industry. The ready-to-go-setup components are ready mounted and do not need any startup efforts after installation!
Fluids: Air for sewage basins or combustion air in process industries
Pipe diameters: 65..500 mm (2,5”-20”) (others on request)
Process conditions: -40..250 °C (others on request)
0..10 bar (others on request)
Ultrapure to higly inpure air
|
|
|
|
|
|
Fluids: Gas, Steam, Liquids
Diameters of pipes/ channels:
0..20 mm deltaflow DF8
15..100mm deltaflow DF10M
65..3000mm deltaflow DF25
500..15000mm deltaflow DF50
Operating conditions:
-250..1240 °C
0..800 bar
Pure to extremely contaminated, aggressive media
Eexia
TRD
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how %u2013 systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
30008
High Flow Filter Regulator Extractor (use for all models)
3 Micron
30003
High Flow Filter Regulator (use for all models)
5 Micron
30002
Low Flow Filter Regulator (use for 0145, 200, 201, 0190 and 602 models)
5 Micron
|
|
|
|
|
|
High tech and sturdy air operated valve, with a floating
plug seal, meeting stringent use criteria.
An extra thick body of the actuator and of the valve, ensuring a good resistance to mechanical and thermal distorsions.
A modular design enabling the following configurations:
Shut off valve DCX3 L
DCX3 T
DCX3 X
Divert valve DCX4 L/L
DCX4 T/L
DCX4 L/T
DCX4 L/X
PFA seals quality ensures a complete sealing at high temperature and a good resistance to aggressive products.
Plastomer seal can be replaced by elastomer seal
Single or double acting connection
With plastomer seal, vertical setting up (especially for DCX4)
Dimensions 1” - 1-1/2” - 2” - 2-1/2” - 3” - 4” - 5” - 6” Material
Body: 316L stainless steel
Shut-off unit: 316L stainless steel
Manual or automatic operating devices: 304 stainless steel
Plug seal: PFA and elastomer
Stem seal: viton, EPDM, silicone
Options
• Signal back equipment on the top of the actuator
• Sterilization of the stem through an upper guide bearing
• External = 47 RA max (150 grit)
• Internal = 32 RA max (180 grit)
Upgraded finishes upon request:
Surface Finish
Variants
Plug and body machined for a metal to metal sealing (without seal)
Elastomer sealing (specific plug with viton, EPDM o-ring)
Manual operator device (instead of the actuator
Tank bottom type
Long stroke valve available upon request
|
|
|
The fine threads of the needle valve permit excellent adjustment for precise control of flow. The flow is restricted in both directions and is adjustable from 0 to the equivalent flow of a 0.025" diameter orifice. The 7-turn adjustment needle valves are available in two models, the standard model and the fine adjustment model. The standard adjustment model has a pin angle of 6° with 10-64 threads; the fine adjustment model has a pin angle of 4° with 10-80 threads.
|
|
The miniature Preset Flow Control is ideal for many applications involving pneumatic systems, including the control of cylinder speed.
The operation of the flow control is based on the movement of a small disc. The flat surface on one side of the orificed disc seals and permits flow through the orifice. The amount of flow permitted in the reverse direction is determined by the orifice size. In the forward direction full flow is permitted. The flow controls design allows a maximum supply pressure of 75 PSI with a minimum cracking pressure of less than 10” H2O. Orifice sizes are available from .004” to .040”.
|
|
Mass Airflow sensors contain a thin-film, thermally isolated bridge structure containing heater and temperature sensing elements. The bridge structure provides a sensitive and fast response to the flow of air or other gas over the chip. State-of-the-art chip design and manufacturing techniques allow the microbridge to be remarkably sensitive, fast, small. Used wherever airflow needs to be measured.
|
|
Delta Controls' flow meters are proven in a broad range of air and gas management applications, including:
-Blow-by gas measurement in engine test beds
-Nuclear, biogas, pharmaceutical, industrial process gas and pollution monitoring
To support both existing and new customers with a high level of meter performance and minimal long-term cost of ownership, Delta offers an extensive recalibration service. Utilising the in-house flow laboratory, quick turnarounds can be achieved to minimise customer downtime.
Delta also offers an ATEX approved, vane operated flow switch, ideally suited to ducted air system applications in hazardous environments.
|
|
|
The fine threads of the needle valve permit excellent adjustment for precise control of flow. The flow is restricted in both directions and is adjustable from 0 to the equivalent flow of a 0.025" diameter orifice. The 7-turn adjustment needle valves are available in two models, the standard model and the fine adjustment model. The standard adjustment model has a pin angle of 6° with 10-64 threads; the fine adjustment model has a pin angle of 4° with 10-80 threads.
|
|
The miniature Preset Flow Control is ideal for many applications involving pneumatic systems, including the control of cylinder speed.
The operation of the flow control is based on the movement of a small disc. The flat surface on one side of the orificed disc seals and permits flow through the orifice. The amount of flow permitted in the reverse direction is determined by the orifice size. In the forward direction full flow is permitted. The flow controls design allows a maximum supply pressure of 75 PSI with a minimum cracking pressure of less than 10” H2O. Orifice sizes are available from .004” to .040”.
|
|
Electric Oden P50H, P220H and P500H lever control valve actuators for special applications.
High precision through the Oden Gear System.
Fits most types of valves using ASAB standardised lever modules and assembly kits
Voltage 24 VDC.
Analogue control 4-20 mA or digital.
|
|
|
|