- Electricity - Electronics >
- Energy: Production and Distribution >
- High-voltage transformer
High-voltage transformers
Output power kVA: 25 kVA - 10,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
... Type Transformers from 25 kVA up to 10.000 KVA up to 36 kV voltage class. Cast Resin Transformers are a cost-effective and convenient alternative to traditional high voltage ...
... Pressure and Oil Over Temperature. Std Transformer is Design, manufacturing and exporting 53 Countries of The hermetically sealed oil transformers STANDARD FEAURES • HV bushings according to DIN ...
Sami Trafo Makina Insaat Imalat Taah. Genel Tic. Ltd. Sti.
Electric power: 0.01, 0.006 kVA
Primary voltage: 230 V
Secondary voltage: 6 V - 24 V
... to ENEC 10-, VDE- and UL-regulations Excellent temperature fluctuation resistance properties High electrical safety and long service-life features High voltage resistance Self-extinguishing cast housing ...
HAHN - Elektrobau
Primary voltage: 275, 500, 200, 550 V
Secondary voltage: 275, 500, 200, 550 V
Primary current: 40,000, 15,000 A
... HIGH ATTENUATION ISOLATION TRANSFORMERSWITH OVERVOLTAGE PROTECTION IREM Isolation Transformers of the RS series are characterized by: the high attenuation of common mode disturbances; the attenuation ...
Primary voltage: 245 kV - 550 kV
Primary current: 5,000 A
Secondary current: 1, 5 A
... combined transformers are used in high- voltage substations within the 245-550 kV range. They transfer high voltage and high current into standardised, ...
PFIFFNER International AG
Primary voltage: 72.5 kV - 145 kV
... instrument transformer • It is oil/paper insulation system, the primary insulation is wound from high voltage cable paper. It will be immersed with transformer oil after desiccating under ...
Secondary voltage: 66, 132, 11, 33, 6.6 kV
... Power Transformers up to 132kV 160MVA Technical Specifications • High efficiency transformers based on European Union EcoDesign Directive •Alternative cooling fluids including Midel and FR3 for environmentally ...
Output power kVA: 50 kVA - 2,000 kVA
Primary voltage: 6.9, 11.5, 40.5 kV
Secondary voltage: 400 V
... series combined transformer substation according to COMBINED TRANSFORMER STANDARD JB/T10217-2000, which immerse the body of transformer, HV load switch, fuses and other protection components ...
Output power kVA: 5,000 kVA - 45,000 kVA
Primary voltage: 11 kV - 70 kV
Secondary voltage: 150, 90, 110, 123, 132 kV
... According to the design of the transformer, windings can be continuous or interleaved disc, simple or multiple helix. Cooling channels are made with duly shaped rods and flow guide rings. Tappings are provided on the ...
... is reduced and power distribution reliability is increased. Performance characteristics 1.The ZGS11 combined transformer consists of high- voltage and low- voltage ...
Andeli Group Company
... HV cast resin transformers have reached a high level of reliability thanks to the latest technologies. The E2, C2, F1 production can be used with high level of humidity and pollution ...
EREMU
Electric power: 0 kVA - 20,000 kVA
Primary voltage: 0 kV - 24 kV
Secondary voltage: 0 kV - 7.2 kV
... distribution transformers are used to convert higher electrical voltages to a lower voltage level. Dry type distribution transformers are environmental, safe and require a minimum amount ...
Trafotek Oy
Output power kVA: 0.06, 0.02, 0.03 kVA
Secondary voltage: 140, 180, 225 kV
Primary current: 50 A - 1,200 A
... this high- voltage (72 kV) outdoor-type current transformer is designed to withstand solar ultraviolet radiation and IEC-defined pollution level III (“Heavy”). About the Product Cast in Araldite® UV-resistant ...
CHALLENGE INDUSTRIAL CO., Ltd
Primary current: 0 A - 90 A
... STS is a global supplier of transformers for high-current industrial processes like aluminum electrolysis or arc furnaces for steel and other metals. Furnace transformers for AC EAF operation have ...
Electric power: 6,300 kVA - 180,000 kVA
Primary voltage: 110 kV
... screen continuous structure to improve the distribution of the impulse voltage wave, which ensure the HV winding insulation strength. Medium and low voltage coils are made of high strength ...
Output power kVA: 4,000 kVA - 200,000 kVA
Primary voltage: 11 kV - 220 kV
Secondary voltage: 3.3 kV - 132 kV
... Power Transformers (Up to 200MVA) Any transformers with higher ratings than the standard distribution transformers (more than 4000kVA and up to 200MVA) can be built as a power transformer ...
Electric power: 0.4, 0.5, 0.005, 0.06 kVA
Primary voltage: 3,000 V - 35,000 V
Secondary voltage: 100, 110, 120 V
... The Zez Silko CT and VT series are high- voltage instrument transformers that are suitable for use in measuring and protecting high- voltage distribution systems of 3.6kV ...
Secondary voltage: 50 kV - 2,250 kV
... The AC test transformers specifically intend for testing high voltage components and products manufactured by POWER High Voltage Test. It is utilized to prompt testing ...
Electric power: 2 W - 6 W
... Piezoelectric transformer (SOLIDFORMER®) can generate a high voltage by a low voltage input through the utilization of a resonance phenomenon of the piezoelectric transducer. The applications ...
Primary voltage: 230, 115 V
Secondary voltage: 0 V - 2,000 V
Primary current: 1 A - 10 A
... excitation curves for instrument transformers • Demagnetize current transformer cores • Conduct turn ratio tests on voltage transformers • Two-handed control enhances ...
... on-line conditions, as the CT100 is a clamp-on current transformer that can be opened and clamped around a connecting cable, a ground lead, or even a feeding medium- voltage cable with a high- voltage ...
Electric power: 1,500 W - 250,000 W
Primary voltage: 200 V - 400 V
Secondary voltage: 50 kV - 250 kV
... insulation defects, and measuring voltage withstand capacity. Introducing our state-of-the-art oil immersed high voltage testing transformer, designed to meet the rigorous demands of ...
Output power kVA: 1.5 kVA - 250 kVA
Primary voltage: 200 V - 500 V
Secondary voltage: 50,000 V - 250,000 V
... determining the voltage withstand capacity. This state-of-the-art oil immersed high voltage testing transformer is engineered to deliver reliable and accurate performance, making it an ...
... AC and DC high voltage tests, making it versatile for a wide range of applications. The use of SF6 gas as the insulation medium ensures high dielectric strength and excellent arc quenching properties, ...
Primary voltage: 6 kV - 220 kV
... The HJ precision voltage potential transformer is a portable calibration standard designed for voltage transformer calibration in power supply and production departments. ...
Output power kVA: 1.5 kVA - 100 kVA
... YDJ Series Oil Immersed Type Testing Transformer can provide high voltage for various HV testing, and AC/DC HV output, to provide HV voltage ...
Electric power: 7.5, 17 kVA
Primary voltage: 220, 380 V
Secondary voltage: 100 kV
... hexafluoride (SF6) test transformer TIOG-100 is designed for testing high- voltage electrical equipment voltage class 10 kV and 35 kV (or higher) using a short-term AC voltage ...