Primary voltage: 115, 230 V
Ignition transformers for high-voltage ignition of gas or oil burners, suitable for ignition and control with one electrode. Features & Benefits: Ignition voltage: ...
Primary voltage: 420 kV
Secondary voltage: 36 kV - 800 kV
Primary current: 0 A - 4,000 A
... revenue metering and protection in high voltage networks, the oil-paper insulated current transformers IMB has the highest base in the world. • Due to the low center of gravity, the ...
ABB AG
Primary voltage: 36 kV - 800 kV
Primary current: 4,000 A
... revenue metering and protection in high voltage networks, the oil-paper insulated current transformers IMB has the highest base in the world. • Due to the low center of gravity, the ...
Primary voltage: 72 kV - 800 kV
World-class CVT for long term performance and reliability Capacitor Voltage Transformer CPB is designed for revenue metering and protection in high voltage networks. It ...
Output power kVA: 63,000 kVA
Primary voltage: 24, 72.5 kV
... space utilization. These distribution transformers are almost maintenance-free, and they are manufactured in accordance with industry and international standards. The VCC dry-type distribution transformers ...
Output power kVA: 20,000 kVA - 1,000,000 kVA
Secondary voltage: 20 kV - 1,100 kV
... of services – from consulting to design, manufacture and transport to commissioning and Transformer Lifecycle Management (TLM). As one of the leading transformer manufacturers worldwide, we offer a tight ...
Siemens High-voltage – Power transmission
The KOTEF is made to manage current and votlage measurements in one unit. This works with sensible components like CTs and VTs. These are made in one insulator to manage different measurements. This is also made in a composite or porcelain ...
Alstom Grid
... discharge measurements on power cables The MCT 120 high-frequency current transformer (HFCT) is specifically designed for periodic partial discharge (PD) measurement and diagnostics on high-voltage ...
Primary current: 25 mA - 1,000 mA
... drive and power circuit Voltage resistance up to 8 kV Ignition current up to 3 A Turns ratio up to 3:1 Ignition currents : 0.1 to 3 A Rise time : 0.3 to 2.3 µs Frequency : ≤ 40000 Hz Attenuation performance : ...
Primary current: 0.1 A - 3 A
... drive and power circuit Voltage resistance up to 4 kV Ignition current up to 1 A Turns ratio up to 3:1:1 Ignition currents : 0.1 to 1 A Rise time : 0.4 to 4 µs Frequency : ≤ 40000 Hz Attenuation performance : ...
Electric power: 30 W - 1,600 W
Secondary voltage: 30 V - 900 V
... inductive voltage transformers). The system duty cycle can be freely chosen and is insured by adding radiators or forced oil-cooling to the transformers. These systems are also suited ...
Primary voltage: 16 V - 150 V
PICO surface mount units utilize materials and methods to withstand extreme temperatures of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications Units manufactured ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified ...
Tesar Srl
Output power kVA: 7.4 kW - 626.7 kW
... a series of transformer products, including 6300~80,000kVA double-winding and three-winding non-excitation voltage-regulating power transformer, 6300~80,000kVA double-winding and three-winding ...
Primary voltage: 33, 36 kV
Secondary voltage: 100 V - 240 V
Frequency: 50, 60 Hz
Installation: outdoor Highest voltage for equipment Um (r.m.s.) 12 up to 36kV Rated power-frequency withstand (induced) voltage (r.m.s.): 75kV Rated lightning impulse withstand voltage ...
Electric power: 34,000,000 W
Primary voltage: 10,000 V
J. Schneider presents starter transformer designed for compressor motors in air separation plants. It has a nominal voltage of 10 kV and can generate 34 megawatt. J. Schneider provides optimized power ...
... emissions. Its distribution transformer or converter transformer works on the lowest possible core losses overall. The company also manufacture oil-insulated transformers, as smoothing ...
Primary current: 50 A - 300 A
Frequency: 50 Hz - 60 Hz
... current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment Um = 0,72kV (other voltages on request) • rated power-frequency withstand voltage 3kV/1min • ...
Celsa Messgeräte España S.L.
Primary current: 50 A - 750 A
Frequency: 50 Hz - 60 Hz
... current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment Um = 0,72kV (other voltages on request) • rated power-frequency withstand voltage 3kV/1min • ...
Celsa Messgeräte España S.L.
Primary current: 200 A - 2,000 A
Frequency: 50 Hz - 60 Hz
... current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment Um = 0,72kV (other voltages on request) • rated power-frequency withstand voltage 3kV/1min • ...
Celsa Messgeräte España S.L.
Primary voltage: 0 V - 2,500 V
Characteristics:Adopt high quality core, voltage transmission voltage transformer. Application: relay protecting, display instrument driving.
YHDC Dechang Electric
YHDC Dechang Electric
YHDC Dechang Electric
Output power kVA: 10 kVA - 5,000 kVA
Primary voltage: 34.5, 150, 200 kV
... distribution transformers to support a variety of applications. Our product lines include pole- and pad-mounted, single- and three-phase solutions, as well as primary and secondary substation transformers, ...
GE Grid Solutions
Primary voltage: 0.3 kV - 35.8 kV
Overview ZGS-ZG modular transformer is designed to meet the growing demands for photovoltaic power supply. This product is designed on the basis of 35kV Pad-mounted transformer. The transformer, ...
Beijing SOJO Electric Co., Ltd
... hermetically sealed. TPS, TPX, TPY and TPZ special core class ratings are available. Low reactance bar-type allows high short circuit currents and high primary current. It is not affected by stray external ...
Trench Group
Since 1984, the current transformers from CG operate with high quality performance in 60 countries. These transformers comply with international quality standards to ensure efficient ...
Primary voltage: 0 V - 245 V
Secondary voltage: 0 kV - 1,050 kV
... high voltage transformers suitable for electrical generation, transmission and distribution applications: Transformers GSU (Generator Step-Up): used to connect the generator voltage ...
SEA
Electric power: 0.01, 0.006 kVA
Primary voltage: 230 V
Secondary voltage: 6 V - 24 V
... UL-regulations Excellent temperature fluctuation resistance properties High electrical safety and long service-life features High voltage resistance Self-extinguishing cast housing and ...
HAHN - Elektrobau
Primary voltage: 100 V
Secondary voltage: 7 kV
... advantage in both inland and abroad logistics. HVU High voltage power supply for electronic minus ion generator. Input AC100V Output7kV Failure output circuit built-in. HVT High ...
Primary voltage: 275, 500, 200, 550 V
Secondary voltage: 275, 500, 200, 550 V
Primary current: 40,000, 15,000 A
HIGH ATTENUATION ISOLATION TRANSFORMERSWITH OVERVOLTAGE PROTECTION IREM Isolation Transformers of the RS series are characterized by: the high attenuation of common mode disturbances; the ...
Primary voltage: 245 kV - 550 kV
Primary current: 5,000 A
Secondary current: 1, 5 A
... combined transformers are used in high-voltage substations within the 245-550 kV range. They transfer high voltage and high current ...
PFIFFNER International AG
Primary voltage: 72.5 kV - 145 kV
72.5kv/132kv/145kv instrument transformer • It is oil/paper insulation system, the primary insulation is wound from high voltage cable paper. It will be immersed with transformer ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining