- Electricity - Electronics >
- Energy: Production and Distribution >
- High-voltage transformer
High-voltage transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Primary voltage: 115, 230 V
Ignition transformers for high-voltage ignition of gas or oil burners, suitable for ignition and control with one electrode. Features & Benefits: Ignition voltage: ...

Electric power: 0.001 W - 0.6 W
Primary voltage: 2 V - 100 V
Secondary voltage: 1 V - 100 V
... procedures without degrading the high reliability of their physical form and electrical performance. Features Extreme resistance to impact, shock, and vibration Manufactured to MIL-PRF-27, Class S, Grade ...
Pico Electronics

Electric power: 1.5 W - 40 W
Primary voltage: 5 V - 48 V
Secondary voltage: 5 V - 300 V
Pico DC-DC converter transformers are ultra-miniature in size as the energy driver to the switch-mode power supplies. They are power efficient in reducing core losses and able to be used in a wide variety of energy conversion ...
Pico Electronics

Electric power: 0.375 W - 2.4 W
Primary voltage: 115, 26 V
Secondary voltage: 5 V - 310 V
... Have Regulation of 17%) Secondary Voltage Adjusted to Nominal Value at Half Load. Smallest Possible Size. Printed Circuit Thru Hole Construction. Secondary Has Split Winding (Secondary Can Be Used at Half Voltage ...
Pico Electronics

Electric power: 1 W - 100,000 W
Primary voltage: 1,000 V - 36,000 V
Secondary voltage: 100 V - 20,000 V
... /LV casted resin dry-type electrical transformers for electrical distribution from 100 to 3150 KV, 20/0.4 kV, in 24kV insulation class. High performance and efficiency even in difficult conditions, to ...

Electric power: 1 W - 100,000 W
Primary voltage: 1 kV - 63 kV
Secondary voltage: 120 V - 52,000 V
... casted resin dry-type electrical transformers for electrical distribution up to 25 MVA, 20/0.4 kV, in 24kV insulation class with special UCC designs. High performance and efficiency even in difficult ...

... discharge measurements on power cables The MCT 120 high-frequency current transformer (HFCT) is specifically designed for periodic partial discharge (PD) measurement and diagnostics on high-voltage ...

Output power kVA: 30 kVA - 2,500 kVA
Primary voltage: 6 kV - 35 kV
Secondary voltage: 0.4 kV
... operated at the load center. • Adopts domestic advanced technology, high mechanical strength, strong short-circuit resistance, minimal partial discharge, good thermal stability, high reliability, and ...

Output power kVA: 50 kVA - 2,500 kVA
Primary voltage: 10 kV
Secondary voltage: 0.4 kV
... . • For oil-immersed power transformers, the low-voltage winding typically adopts a cylindrical structure made of copper foil winding, except for those with smaller capacities, which use copper wire. • ...

Output power kVA: 0.01 kVA
Primary voltage: 10 kV
Primary current: 5 A - 1,000 A
This outdoor current transformer is an epoxy resin full enclosed pillar product. It is used for electric energy metering, current metering and relay protection. This CT meets the standard of IEC185 and GB1208-2006 . It ...

Output power kVA: 2,000 kVA
Primary voltage: 11 kV
Secondary voltage: 0.4 kV
... 1. Precise High-voltage Adaptation It precisely adapts to the 10kV high-voltage input, optimizing winding design and electromagnetic parameters to ensure stable electrical ...
LUSHAN CHINA

Output power kVA: 630 kVA
Primary voltage: 10 kV
Secondary voltage: 0.4 kV
Product Overview: In substations, it converts high-voltage electricity into suitable voltages. It realizes power distribution and transmission, connects high-voltage ...
LUSHAN CHINA

Output power kVA: 35 kVA
Primary voltage: 33 kV - 35 kV
Secondary voltage: 0 V - 800 V
... -immersed transformers for power transmission have large capacity, long service life, and stable operation. They are the key hubs for long-distance power transmission in the power grid. Specific Introduction: i.Large ...
LUSHAN CHINA

Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Secondary voltage: 13.2 kV
... temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m
Dowei Electric

Output power kVA: 630 kVA - 63,000 kVA
Primary voltage: 66,000 V
Secondary voltage: 13,200 V
... temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m
Dowei Electric

Output power kVA: 6,300 kVA - 120,000 kVA
Primary voltage: 110 kV
Secondary voltage: 13.2 kV
... temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m
Dowei Electric

Output power kVA: 7.4 kW - 626.7 kW
... voltage-regulating power transformer, 6300~80,000kVA double-winding and three-winding on-load voltage-regulating power transformer. Product application: power plants, substations, ...

Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl

Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl

Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified ...
Tesar Srl

Primary voltage: 33, 36 kV
Secondary voltage: 100 V - 240 V
Frequency: 50, 60 Hz
Installation: outdoor Highest voltage for equipment Um (r.m.s.) 12 up to 36kV Rated power-frequency withstand (induced) voltage (r.m.s.): 75kV Rated lightning impulse withstand voltage ...

Primary voltage: 36 kV - 800 kV
Primary current: 4,000 A
... revenue metering and protection in high voltage networks, the oil-paper insulated current transformers IMB has the highest base in the world. • Due to the low center of gravity, the ...
Hitachi Energy

Secondary voltage: 500 kV - 1,100 kV
... superior transformers in different HVDC schemes like HVDC Classic and HVDC Plus. HVDC converter transformers are indispensable, where ...
Siemens Energy – Power transmission

GE’s cast coil transformer is a low-noise, low-loss, cast resin dry-type transformer. The high-voltage winding with copper conductors and the low-voltage ...
GE Grid Solutions

Primary voltage: 420 kV
Secondary voltage: 36 kV - 800 kV
Primary current: 0 A - 4,000 A
... revenue metering and protection in high voltage networks, the oil-paper insulated current transformers IMB has the highest base in the world. • Due to the low center of gravity, the ...
ABB AG

Since 1984, the current transformers from CG operate with high quality performance in 60 countries. These transformers comply with international quality standards to ...

Primary voltage: 0 V - 245 V
Secondary voltage: 0 kV - 1,050 kV
... high voltage transformers suitable for electrical generation, transmission and distribution applications: Transformers GSU (Generator Step-Up): used to connect the generator voltage ...
SEA

Electric power: 30 W - 1,600 W
Secondary voltage: 30 V - 900 V
... inductive voltage transformers). The system duty cycle can be freely chosen and is insured by adding radiators or forced oil-cooling to the transformers. These systems are also suited ...

Primary voltage: 0.3 kV - 35.8 kV
Overview ZGS-ZG modular transformer is designed to meet the growing demands for photovoltaic power supply. This product is designed on the basis of 35kV Pad-mounted transformer. The transformer, ...
Beijing SOJO Electric Co., Ltd

... hermetically sealed. TPS, TPX, TPY and TPZ special core class ratings are available. Low reactance bar-type allows high short circuit currents and high primary current. It is not affected by stray external ...
Trench Group

Frequency: 50 Hz
... no-load loss; the transformer windings are all made of high-quality pure copper, high, Low-voltage winding system, compact structure, small size and light weight. The ...
Hezong Science and Technology Co., Ltd.

... the voltage drop (typically 10kV on typical transmission line) would mean that little or no power could actually be transmitted. The generator transformer typically consists of a low voltage ...
Smit Transformatoren

Electric power: 10,000 kVA
Primary voltage: 36 V
... Item : Dry Type Mold Cast Resin Transformer Specification : Max. Manufacture voltage & capacity: 36KV & 10MVA. Features: High Voltage Coils: 1. Conductor Material: ...

Primary voltage: 115, 230 V
Secondary voltage: 115, 230 V
Transformer Type: These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter ...

Primary voltage: 0 V - 2,500 V
Characteristics:Adopt high quality core, voltage transmission voltage transformer. Application: relay protecting, display instrument driving.
YHDC Dechang Electric

Output power kVA: 1 kVA - 500 kVA
Secondary voltage: 600 V
... recommendation of each country's national standards • Temperature based on IEC726 • High voltage winding: F class • Low voltage winding: F class • Bottom entry gland plates for HV ...
Riye Electric
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining