Accepting the signal from our speed sensors and from a variety of transmitters with a pulse or AC-output. The unit provides alternative input paths for high level and low amplitude. Performance data easy programmed locally at the unit by incorporated keys.
Incorporated 2 speed alarms with SPDT relay contacts. Response characteristics individually programmable: setpoints, response characteristics and starting conditions.
Optional one 20 ma analog output with programmable span.
Signal frequency range 0 – 100 kHz.
Supply from 18-40 v or 85-265 v AC or DC.
Main design for snap-on-track, optionally in IP65 outdoor or ATEX Ex-proof enclosure.
|
|
Although modern machines are controlled centrally, complex installations often benefit from local fine-tuning and a display for operators to determine the machine status. JAQUET tachometers and speed switches are used in a wide variety of applications. Our extensive product line provides optimum solutions for both information and control.
Whether it's a digital tachometer, an analog indicator, a converter or a switch, you can rely on JAQUET for the right speed sensing equipment.
|
|
| ... products without technical information |
| |
VisConnect 4-20 mA Analog Output Module
VisConnect is a stand-alone, analog/digital output hub that provides access to ViSmart-delivered data via a standard 4-20 mA output signal, allowing customers to acquire multiple channels of continuous viscosity and temperature data and integrate that data into any host control platform, without the use of expensive instrumentation.
The VisConnect has two loop-powered, galvanically isolated channels of 4-20 mA output, allowing customers to configure the minimum and maximum analog outputs to correlate to 4 mA and 20 mA, or optional 0.5V to 4.5V, respectively. With an optional 2 channel analog voltage output, standard communications protocol for industrial applications, the VisConnect can connect to any legacy DAQ or host control system. An RS232 Serial communication interface is present, and an optional CAN interface will be made available in the future.
|
|
PRODUCT RANGE GENERAL PRESENTATION
The electronic allows the vibration of the viscometer and processes the amplitude variations in order to deliver a linear viscosity response.
960X range
• Viscosity and temperature processor
• Density for kinematic viscosity measure (optional)
• Flush-type mounting
• 24 keys keyboard and graphic display
• User friendly utilisation
• Analogic current outputs 4-20mA, relays, RS 232 - RS 485
800x RANGE
• Viscosity controller
• Maximal process temperature 200°C or 300°C
• Flush-type mounting
• Analog output 4-20 mA
• RS 485 output
• Output relay (switching power 2A - 250VAC)
7000 RANGE
• Viscosity and temperature transmitter
• Maximal process temperature 100°C
• Mounting on standard DIN rail
• Analog output 4-20 mA
• RS 485 output
|
|
|
|
|
|
● ExMGZ 100/200.ATEX
ExMGZ 100 / 200.ATEX Intrinsically Safe Barrier The ExMGZ 100/200.ATEX intrinsically safe barrier is used for applications in intrinsically safe or explosion proof environments classified as II(2)GD [EEx ib] IIB / IIC. It is designed for single or double channel tension measurement and can be used with any FMS amplifier, controller, and force sensor. The ExMGZ 100 / 200.ATEX units
are DIN rail mountable, utilize screw terminal connections and are easy to install between the electronic unit in an unprotected area and a force sensor in a protected area.
● Functional description
The ExMGZ 100/200.ATEX intrinsically safe barrier utilizes a zener limiter on the force sensor side. It controls the voltage to the force sensor while preventing over voltage. A zener barrier is provided for each channel on the intrinsically safe side. Therefore the explosion proof area remains safe from hazardous voltage levels while still allowing the tension measurement or control to perform in the process. A control circuit ensures that the voltage drop of the zener barrier is compensated and it is guaranteed that the full excitation voltage is provided to the force sensors.
|
|
VisConnect 4-20 mA Analog Output Module
VisConnect is a stand-alone, analog/digital output hub that provides access to ViSmart-delivered data via a standard 4-20 mA output signal, allowing customers to acquire multiple channels of continuous viscosity and temperature data and integrate that data into any host control platform, without the use of expensive instrumentation.
The VisConnect has two loop-powered, galvanically isolated channels of 4-20 mA output, allowing customers to configure the minimum and maximum analog outputs to correlate to 4 mA and 20 mA, or optional 0.5V to 4.5V, respectively. With an optional 2 channel analog voltage output, standard communications protocol for industrial applications, the VisConnect can connect to any legacy DAQ or host control system. An RS232 Serial communication interface is present, and an optional CAN interface will be made available in the future.
|
|
PRODUCT RANGE GENERAL PRESENTATION
The electronic allows the vibration of the viscometer and processes the amplitude variations in order to deliver a linear viscosity response.
960X range
• Viscosity and temperature processor
• Density for kinematic viscosity measure (optional)
• Flush-type mounting
• 24 keys keyboard and graphic display
• User friendly utilisation
• Analogic current outputs 4-20mA, relays, RS 232 - RS 485
800x RANGE
• Viscosity controller
• Maximal process temperature 200°C or 300°C
• Flush-type mounting
• Analog output 4-20 mA
• RS 485 output
• Output relay (switching power 2A - 250VAC)
7000 RANGE
• Viscosity and temperature transmitter
• Maximal process temperature 100°C
• Mounting on standard DIN rail
• Analog output 4-20 mA
• RS 485 output
|
|
|
|
|
|
For over 35 years, LDS Nicolet has provided state-of-the-art data acquisition solutions for the test and measurement community. Today, we are the world's premier provider of out-of-the-box, ready to use systems for a diversity of physical and electrical applications. The Genesis system builds on a reputation of high performance acquisition and signal conditioning by providing a flexible, cost effective platform to meet all data acquisition and transient acquisition needs. With the Genesis, LDS Nicolet introduces the future of data acquisition.
Based on the concept of a mainframe with plug-in modules, the Genesis offers a wealth of capabilities. Up to 128 channels can be installed within a rack mainframe (56 channels in the portable tower mainframe), and multiple mainframes can be combined to an even larger system. Up to 400 MegaSample memory per board allows for high definition transient capture. Built-in data transfer acceleration gives you an overview of MegaSamples of data within seconds. With the world's best performance signal conditioning and 16-bit accuracy, Genesis is the right solution for your difficult measurement task.
Genesis Features
Combines Transient Recorder and Streaming Data Acquisition Capabilities
Programmable High-Performance Signal Conditioning
Sample Rates from
200 kS/s to 100 MS/s per Channel
Transient RAM to 400 MS per card, 12.8 GB per System Max.
Tower Mainframe with 7 slots or Rack Version with 16 slots (see lower picture)
Master Slave Option for Synchronized Acquisition on up to 1080 Channels
Unlimited Recording Size and Duration
IRIG and GPS Time Code Options
Local SCSI Drive Storage for Safety Critical Applications
|
|
|
|
|
|
For over 35 years, LDS Nicolet has provided state-of-the-art data acquisition solutions for the test and measurement community. Today, we are the world's premier provider of out-of-the-box, ready to use systems for a diversity of physical and electrical applications. The Genesis system builds on a reputation of high performance acquisition and signal conditioning by providing a flexible, cost effective platform to meet all data acquisition and transient acquisition needs. With the Genesis, LDS Nicolet introduces the future of data acquisition.
Based on the concept of a mainframe with plug-in modules, the Genesis offers a wealth of capabilities. Up to 128 channels can be installed within a rack mainframe (56 channels in the portable tower mainframe), and multiple mainframes can be combined to an even larger system. Up to 400 MegaSample memory per board allows for high definition transient capture. Built-in data transfer acceleration gives you an overview of MegaSamples of data within seconds. With the world's best performance signal conditioning and 16-bit accuracy, Genesis is the right solution for your difficult measurement task.
Genesis Features
Combines Transient Recorder and Streaming Data Acquisition Capabilities
Programmable High-Performance Signal Conditioning
Sample Rates from
200 kS/s to 100 MS/s per Channel
Transient RAM to 400 MS per card, 12.8 GB per System Max.
Tower Mainframe with 7 slots or Rack Version with 16 slots (see lower picture)
Master Slave Option for Synchronized Acquisition on up to 1080 Channels
Unlimited Recording Size and Duration
IRIG and GPS Time Code Options
Local SCSI Drive Storage for Safety Critical Applications
|
|
|
|