video corpo

Voltage tester DUSPOL®
continuityphase sequencefrequency

Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 2
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 3
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 4
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 5
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 6
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 7
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 8
Voltage tester - DUSPOL®  - Benning - continuity / phase sequence / frequency - image - 9
Add to favorites
Compare this product

Characteristics

Test type
voltage, continuity, phase sequence, frequency
Tested product
detector
Configuration
portable
Other characteristics
digital, with LCD screen, analog, non-contact

Description

phase-sequence test (counter-clockwise / clockwise) single-pole phase test: „⚡" symbol (red LED) measuring point illumination acoustic and optical continuity test frequency measurement 1 – 1000 Hz voltage indication 1 – 1000 V AC TRUE RMS / 1200 V DC resistance measurement and diode test with conducting-state voltage indication lc display with background lighting sensor of non-contact cable break detector load connection via large-scale push buttons vibrating alert in the test handle shock-resistant housing with protection against dust and water jets (protection class IP 65) and rubberized test handle DIN EN 61243-3 (VDE 0682-401): 2015 standard tested and approved in compliance with the current DIN EN 61243-3 (VDE 0682-401) standard, CAT IV 600 V respectively CAT III 1000 V safe voltage testing up to 1 - 1000 V AC/ DC vibrating alarm for safe voltage detection high resistance voltage test without push-button activity part time load circuit, no measuring errors due to irritating capacitive and inductive voltages by means of intended load connection via push buttons intentional tripping of a 30 mA RCD battery-independent voltage indication from 50 V AC/DC on acoustic continuity check via buzzer and yellow LED (DUSPOL® expert, DUSPOL® digital) phase sequence test in a three-phase mains single-pole phase test

Catalogs

No catalogs are available for this product.

See all of Benning‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Intersolar 2026
Intersolar 2026

23-25 Jun 2026 Munich (Germany) Hall B3 - Stand 490

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.