video corpo

Flow meter with mass flow controller EX-FLOW Ex-Protected
thermalmassfor gas

Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 2
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 3
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 4
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 5
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 6
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 7
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 8
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 9
Flow meter with mass flow controller - EX-FLOW Ex-Protected - Bronkhorst - thermal / mass / for gas - image - 10
Add to favorites
Compare this product

Characteristics

Technology
thermal
Type
mass
Fluid
for gas
Installation
in-line
Material
stainless steel
Communication
4-20 mA, analog output, digital output, Modbus, PROFIBUS
Supply voltage
DC
Protection level
rugged, ATEX, intrinsically safe, IP65
Other characteristics
with mass flow controller
Volumetric flow rate

Min.: 0.2 l/min
(0.0528 us gal/min)

Max.: 183,333.3333 l/min
(388,461.3339 us gal/min)

Process temperature

Min.: -10 °C
(14 °F)

Max.: 70 °C
(158 °F)

Process pressure

Min.: 64 bar
(928.24 psi)

Max.: 700 bar
(10,152.64 psi)

Precision

1 %

Repeatibility

0.2 %

Description

The Mass Flow Meters of the EX-FLOW series are of rugged design and suitable for gas flow applications in hazardous areas. The intrinsically safe measuring head is IECEx and ATEX tested and can be used up to Zone 1 or EPL Gb flammable gas atmospheres with an ambient temperature up to +70ºC with marking II 2 G Ex ib IIC T4 Gb. The housing of the electronics compartment is rated to IP65. Gas Flow Control in hazardous areas In combination with Bronkhorst® control valves, Mass Flow Meters (MFM) can be used as Mass Flow Controllers (MFC). Control valves can either be integrally or separately mounted, to measure and control gas flows. EX-FLOW valves are equipped with explosion protected coils, available in two executions: Coil type XB : protection method "intrinsically safe"; rated for use up to Zone 0/20 Gas and Dust Ex-atmospheres with marking II 1 G D Ex ia ta IIC // IIIC T6 T80ºC Ga Da. Coil type XC : protection method "increased safety"; rated for use up to Zone 1/21 Gas and Dust Ex-atmospheres with marking II 2 G D Ex eb tb IIC // IIIC T4 T130ºC (Equivalent IECEx Gb Db rating on request) The electrical connection of the flow meter and the control valve to the power supply/readout system (located in the safe zone) is achieved via separate cables. The readout system contains a controller function pc-board to complete the control loop.