Version : relative and absolute pressure
Process connection 1''BSPM, CLAMP or SMS
Technology : Thick enameled strain gauge on ceramic support
Output 2 wires - 4-20 mA
Global error: +/-0.2% FS
Setting Zero and span
features:
» Flush ceramic cell
» No retention area and no fluid filling
» 316L stainless steel head and housing (reinforced tightness)
» Terminal connection
» Axial or radial cable gland
Options:
» Intrinsic Safety
» Flush diaphragm
» Oygen cleaning
» Reinforced P. Max.
» Rangeability of 50 to 100% FS
Function
2 wires, 4/20mA output gauge pressure (TR) or absolute pressure transmitter (TA) with flush ceramic cell technology. Advantages : no retention area and no fluid filling.
Sensing elementFlush ceramic cell
Overpressure limit Refer table backside
Power supply 12 to 28 Vdc
Protection against reverse polarity.
Output signal 4/20 mA , 2 wires
Substituted values≈ 3.7 mA or ≈ 25 to 27 mA
In case of strain gauge breaking
Zero / span adjust.± 3 %
As option (See backside) rangeability of 50 to 100% of F.S.
Load R(Ω)=(Usupply-12V)/0.02A
Max global error ≤ 0.2% FS (at 25°C)
≤ 0.5% FS (at 25°C) see backside
Linearity*+ Hysteresis + Repeatability
*Best straight line with forced zero
Temperature drift ± 0.03%/°C FS
(Compensated T° between 0 and 50°C)
Housing 316L stainless steel
Process connection 316L stainless steel1» BSPM, CLAMP or SMS
Protection IP 66
Electrical connection On internal terminals and metallic cable gland ISO12 (Ø4-8mm)