Band heater
100 - 450 W
Vulcanic
SEALED MICA BAND HEATERS :
Ideally suited for heating cylindrical shapes in damp
environments, in the presence of fatty matter, molten
plastic, rubber, etc.(350°C maximum). Provided with
brass or stainless profile shielding, brazed connection
cover and clamping device offering compact overall
dimensions.
Power supply voltage: 230 V 1P.
Output is by a flexible metal braid 1 m long protecting
the two power supply conductors with one ground
wire.
MICA BAND HEATERS:
These collars resolve all heating problems for cylindrical
shapes up to a temperature of 350°C. They
are loaded to a maximum of 4W/cm2. The heating
element is enclosed in a sheet metal structure; the
fast coupling system allows easy assembly and disassembly.
Power supply voltage: 230 V 1P. Outputs
are by M5 or M7 ( starting from 350 W) threaded
terminals.
Our technical advice :
Taking precautions, it is possible to open Mica collars
with diameters ≥ 100 mm. This operation must
only be performed once, taking care not to damage
the heating part. Finalise tightening when the collar
reaches its working temperature.
They are delivered without caps.
Ideally suited for heating cylindrical shapes in damp
environments, in the presence of fatty matter, molten
plastic, rubber, etc.(350°C maximum). Provided with
brass or stainless profile shielding, brazed connection
cover and clamping device offering compact overall
dimensions.
Power supply voltage: 230 V 1P.
Output is by a flexible metal braid 1 m long protecting
the two power supply conductors with one ground
wire.
MICA BAND HEATERS:
These collars resolve all heating problems for cylindrical
shapes up to a temperature of 350°C. They
are loaded to a maximum of 4W/cm2. The heating
element is enclosed in a sheet metal structure; the
fast coupling system allows easy assembly and disassembly.
Power supply voltage: 230 V 1P. Outputs
are by M5 or M7 ( starting from 350 W) threaded
terminals.
Our technical advice :
Taking precautions, it is possible to open Mica collars
with diameters ≥ 100 mm. This operation must
only be performed once, taking care not to damage
the heating part. Finalise tightening when the collar
reaches its working temperature.
They are delivered without caps.
-
zoom