... Smoke aspiration systems for active and safe room monitoring The timeframe between the start of the fire and its detection is the key to successful fire fighting. Smoke aspiration systems are systems for room monitoring with threshold value alarms. ...
... The steam quality test kit (option "A") is utilized to monitor the steam dryness value, the steam superheat value and the non-condensable gas value. The practice of steam quality testing is carried out worldwide and has been an EU requirement ...
Thermal Detection
... Steam Quality Testing is designed for steam sterilization cycles. It has a very high quality steam is an crucial requirement for preserving finest results according to EU requirement (EN 285) and the practice adopted worldwide. Option B type assures ...
Thermal Detection
... Steam Quality Test Kit (Option ‘C’) is Thermal Detection's most demanded product. Steam Quality Testing has been an EU requirement for many years (EN 285) and the UK Health Service Standard HTM2010. High quality steam is an essential requirement ...
Thermal Detection
Flow: 0 l/min - 0.5 l/min
Pressure: 0 mbar - 500 mbar
Head: 17 mm
... CMP-11G,mini gas pump,diaphragm micro pump are well suited for gas sampling, transferring, evacuating and compressing air and neutral or corrosive gases as well as vapors. Technical Features: 1. Uncontaminated flow. 2.Non-metallic construction. 3.Compact ...
... NIR-II Small Animal Imager Imaging in the Second Biological Window IR VIVO is an infrared multispectral imager for small animal studies. This system benefits from reduced light scattering, absorption and auto-fluorescence by using a detection system ...
... Open near infrared fluorescence imaging The LightIR is an open fluorescence imaging device designed for preclinical fluorescence imaging or clinical research. Key Features: 1. Near infrared fluorescence and NIR-II fluorescence 2. Preclinical studies, ...
... Assesses the quantity and size of dust particles on blast cleaned surfaces in accordance with ISO 8502-3 •Includes all report forms and accessories required for dust tape testing in accordance with ISO 8502-3 •Can be used as a pass/fail test or to ...
Temperature: -40 °C - 2,500 °C
The Impac® 600 series is a digital, modular pyrometer that provides a highly customizable design with easy installation and maintenance for non-contact temperature measurements for various surfaces. The long-wavelength IN 600 is best suited for non-contact ...
ADVANCED ENERGY
... The IsoMon Dual-Channel Gas Detection system is specifically designed for monitoring complete decontamination cycles from start to finish, in isolators or other chambers, using hydrogen peroxide sterilization (H2O2). Dual Channel Gas Monitoring for ...
... consisting of: 1 pc Flow-Cell stainless steel 316 with connectors Swagelok 6 mm 1 pc Septa ...
The EC301 gives electrochemists the opportunity to equip their labs with high compliance, research-grade instrumentation at a very attractive price. Stand-alone front-panel operation allows easy use in the field or in handling routine electrode preparation. ...
... Features: * Checks for Carbon Dioxide (CO2) concentrations * Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor * CO2 measurement range: 0 to 6,000ppm * Temperature measurement range: -4 to 140°F (-20 to 60°C) ...
Measuring pH using DrDAQ is achieved using the DD011 pH electrode which plugs in to the dedicated BNC connector on the DrDAQ logger. It covers the full 0 to 14 pH range, and its robust epoxy body makes ideal for educational use. The electrode comes complete ...
... The MecoTrode pH sensors are designed for processes in the chemical industry with extreme pH values. They are constructed from a H-glass type membrane which provides a low alkaline error and stable measurement even at high temperatures. Three high-performance ...
Hamilton Process Analytics
... PMsense is a PM1.0, PM2.5 and PM10 Particulate Matter transmitter with RS485 Modbus-RTU output, suitable for outdoor air quality monitoring. The dust particles concentration is measured using the laser scattering principle. The transmitter is maintenance-free ...
Delta OHM
... Professional Kit Contents • AM-550-EUR (Digital multimeter) • ACDC-100 TRMS (digital AC/DC current clamp) • IR608A infrared thermometer • EU-200 (test lead set with 2 leads), 2 test prods (4 mm), 2 crocodile clips CAT III/1000 V • Hard carrying ...
... calomel electrode for measurements in very small volumes long-term stable (electrolyte with saturated KCl solution and KCl reserve) shaft diameter: 5 mm standard glass cone (NSK 7) is available → for gas tight mounting in corrosion measuring cells with ...
Sensortechnik Meinsberg GmbH
... Test room & workplace indoor air quality Measure up to 4 gases anytime Test commercial catering gas appliances for UK CP42 certificates - meets CIS23 & BS8494* Test commercial catering & workplace ventilation airflow, temp & RH Test domestic & commercial ...
Kane International
... • colony counter • magnifying glass, optical power 3.25 diopters • standard marker • bright or dark background • Wolfhuegel scale plate • Petri plates adapters TECHNICAL DATA - controller - microprocessor display - LED ...
Temperature: 100 °C - 3,000 °C
The digital pyrometer PYROSPOT of sériés 11 are developed and manufactured in Germany and are suitable for industrial continuous opération. They are used specifically in Steel industry, kiln engineering, soldering installations as well as in ceramic and ...
DIAS Infrared
... * Real time recorder, save the data into the SD memory card and can be downloaded to the Excel, extra software is no need. * Air quality measurement, multi-function and only use one probe to cover the whole measurement : CO2 ( Carbon dioxide ), O2 ( ...
Lutron
Temperature: 80, 2,000 °C
... INDUCTION Heating Systems CEIA SH15/SLE Compact Pyrometers for Measurement of metallic surfaces between 80°C and 2000°C emperature Range from 80°C to 2000°C Emissivity adjustable from 0.1 to 1 High Accuracy High-Speed Compact design Available with different ...
CEIA
Thermal desorption (TD) uses heat and a flow of inert gas to desorb VOCs and SVOCs from sorbents or sample materials. Extracted vapours are swept onto an electrically-cooled sorbent-packed focusing trap, which is then rapidly heated. This injects the ...
... A cost effective and accurate way to count colonies of bacteria or other microorganisms grown on an agar plate. • Fast, accurate and economical sample counting and sample count verification • Marks, counts, and gives an audible and visual alert ...
... MAKE THE IMPACTS VISIBLE Impacts caused by vehicles such as forklifts are sometimes perceived as minor and insignificant, and are therefore not systematically reported by operators. However, these incidents can lead to serious consequences. For example, ...
The Wöhler KM 410 Indoor Air Quality Meter is the perfect instrument for verifying HVAC system performance and air ventilation control
... The heart of every cytometer is a high-precision quartz glass flow cell with a superfine channel. This channel provides stability of the fluidic system and thus enables the precise optical analysis of single cells or particles. The flow channel typically ...