... Loneworker and Safety Communicator. Available with several wireless technology options: Mesh / Wi-Fi / NB-IoT Real-time gas concentration reading, location, alarm and status enabled by state of-the-art wireless technology Bluetooth® ...
Emerson's Rosemount Analytical OPM 3000 Opacity Dust Density Monitor stackmounting transmissometer sensor system includes a retro reflector mounted on one side of the stack and an optical transceiver on the other. The ...
... Fitting stack diameters of 0.3m-15m (1 ft-50ft), 4500 MkIII is suitable for the continuous monitoring of dust and opacity in boilers, heaters, furnaces and other combustion applications in the power generation, ...
... water is not present. With a rugged design suitable for a wide range of applications, it features a highly stable optical system, with large-area collection, offering a low detection limit of less than 1 mg/m3. Operating ...
... measurement you need. Ideal for combustion applications where an automatic calibration check is not required, the 440 is suitable for use power generation, industrial boilers and pulp & paper industries. A TRUSTED ...
... for reduced downtime, and compact size for improved space productivity in order to meet the precise chemical solution concentration management required in leading-edge semiconductor wet process. Reduced Sizes for More ...
HORIBA STEC
... dust (noise) monitoring system monitors the concentration of particulate matter by the national standard β-ray method, and is mainly composed of a particulate concentration ...
AnHui Wanyi Science and Technology Co., Ltd.
... forward scattering method is adopted, the sensitivity of low-concentration measurement is high. The core component of LD1200 system is a light scattering sensor, of which the particulate concentration ...
AnHui Wanyi Science and Technology Co., Ltd.
CEMS 1000 system is composed of a gaseous pollutant monitoring subsystem, a particulate monitoring subsystem, a flue gas parameter monitoring subsystem and a data acquisition ...
AnHui Wanyi Science and Technology Co., Ltd.
... are reported in mg/m³ and provides early indication of increased dust emissions in processes with low dust concentrations - Non-intrusive system designed to operate in noncondensing stack environments ...
AMBIENT AIR DUST MONITORING Continuous dust monitoring in ambient air: control system areas, silo areas, boiler houses, work stations AirSafe 2 is an electrodynamic dust sensor ...
... Also available in a completely dustproof version - Option: Rack version with mounting brackets for 19″ racks The VM-3000 can be combined with a multiplexer unit for automatic monitoring ...
The DustMonitor DM 800 is a calibrated system for continuous measurement of dust concentrations in exhaust pipes and chimneys, and for monitoring dust filters and dust extraction systems. The ...
Polluvision™ Test Kit Portable Mini-lab for analyzing Oil Contamination Results to NAS1638, NF E48-655 and ISO4406 standards The GESERCO POLLUVISION™ Test Kit allows for determination of the particles contamination of used oils. It ...
Equipment according to microparticulate matter (PM2.5) measurement in the "Environmental Monitoring Manual (6th Edition)" of the Ministry of the Environment Beta-ray Absorption Type Source14C Adopted Built-in dehumidifier ...
DKK-TOA CORPORATION
Our solutions are suited to a wide variety of applications, from dosing control to ABV/ alcohol monitoring, the product is widely used amongst leading global beverage, pharmaceutical , nuclear & energy ...
Specifications Temperature -3 to +25 °C Concentration 0 to 20 °Plato Pressure 1 to 10 bar
... wide ambient temperature range BENEFITS Easy installation for opacity monitoring and reliable emission monitoring Reliable measurement of medium to large dust concentrations Space-saving ...
... contamination Automatic control functions Contactless measurement Maintenance and linearity check without disassembly BENEFITS Suitable for official emission monitoring Reliable measurement of ...
... eliminate air bubbles. Direct measurement is easier than traditional analysis methods. Continuous online monitoring and real-time control of water quality.
... bring water samples from your system to a laboratory for microbial water quality testing. Tomorrow, our automation add-ons can measure directly in your system. This allows you to accurately monitor bacterial ...
... dust concentration / opacity monitor measure correlation between manual analysis and absorbance continuously. It employs light transmission method to be built in while LED and auto collimation function, which enables ...
... check. Intégral high efficiency air curtains for maximum uninterrupted service. Typical Dust Monitoring Applications Large Combustion Plants Small Combustion Plants Cement Plants Dust ...
Codel International
... Descriptions】 The YEM-42 series of instruments are mainly used for environmental carbon dioxide concentration and temperature and humidity monitoring, suitable for home, classroom and office space. YEM-42 ...
... ~ 0.8MPa N2, clean air Application 1. Ammonia slip emission monitoring 2. Process control of SCR or SNCR deNOx device 3. Coal-fired power plant 4. Aluminium plant 5. Steel mills ...
Hangzhou Zetian Technology CO., Ltd
The SMG100 is suitable for the mobile review and monitoring of dust emissions, especially at high temperatures. Calibration of combustion plants Monitoring of dust filters, ...
Remote Dust Monitoring systems Given the uncertainty regarding future dust emissions and their potential large impact in human lives and the economy, the importance of deploying alert mechanisms for ...
... with latest IMO regulations - Certified system for emission monitoring in marine industry - Type approved by all major classification societies Decrease maintenance hassle by increased system ...
EXPEC-2000 belongs to the Continuous Emission Monitoring System designed with gas chromatography (GC) technology and flame ionization detector (FID) to measure volatile organic compounds online, applying ...
Focused Photonics Inc.
CEMS-2000 B Emission Monitoring System Product overview As a leading supplier of international popular analytical equipment, FPI has found the best solution to this problem by introducing our newest ...
Focused Photonics Inc.
Product overview The CEMS-2000B FT Continuous Emission Monitoring System is designed to extract and transport a flue gas sample for the measurement of gaseous pollutants concentration ...
Focused Photonics Inc.
... possible to control areas of up to 250 m2. SF6 gas is five times heavier than air, therefore breathing air can be displaced in case of higher concentrations of SF6 gas so that there is a risk of suffocation. The ...
Precision emissions control at your fingertips The DSL-800 is a laser backscatter optical instrument designed to monitor the concentration of particulate matter passing through a duct, stack or flue ...
... process gas quality and quantity monitoring, with kinds of advanced technology such as NDIR, Micro NDIR, UV DOAS etc.. Inspired by environmental concerns, Cubic Ruiyi Gasbaord-9085 is designed to measure the emission ...
Introduction The continuous emission monitoring system incorporates with on-line flue gas analyzer Gasboard 3000 models for precise, real-time monitoring. Based on micro flow NDIR technology ...
... gas monitoring, low-nitrogen reform environmental monitoring, energy efficiency monitoring, nitrogen oxide concentration monitoring in low-nitrogen ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining