- Electricity - Electronics >
- Switch and Relay >
- DC monitoring relay
DC monitoring relays
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Tripping current: 1 A - 12 A
Trigger voltage: 24 V - 240 V
... True power monitoring device for measuring and monitoring the true power of electrical loads, limit values that can be set via display, can be saved to chip card, relay output: 2 changeover contacts, analogue ...
Trigger voltage: 24 V
... supply voltage U1 - DC Power consumption DC - 1.5 W Max. device circuit breaker - Max. conductor cross section Relay outputs Utilisation cat. AC/ DC1 stand. - ...
Trigger voltage: 12 V - 24 V
... PRO relay monitors undervoltage to protect motors and equipment from being damaged by blowouts. The multi timer can sense a maximum voltage of 24 V DC and has a single pole double throw (SPDT) contact ...
... SLS (safely limited speed), SSM (safe speed monitoring), SSR (safe speed range) and SDI (safe direction) in accordance with EN 61800-5-2. Advantages and customer benefits - Direction of rotation monitoring ...
Trigger voltage: 1,000 V
... repeat accuracy • Wide measuring range DC 20 … 1000 V • Easy setting • Protection against manipulation by sealable transparent cover over setting switches Features • According to IEC/EN 60255-1 • For DC ...
Tripping current: 0.32 A - 16 A
... changeover relays 16A/250V, usable as 1 relay for each current threshold or 2 relays for a single threshold depending on the setting. - Current Measurement: Selection of alternating or direct current. ...
Trigger voltage: 9 V - 80 V
... Type | Product Stocked CRV1- DC12 | DC 12V | instock CRV1- DC24 | DC 24V | instock - Features / Technical Specifications: - Voltage monitoring on DC ...
Trigger voltage: 20 V - 240 V
... voltage: 110...230 VAC | Vc: 100...240 VAC/ DC Supply voltage: 24...48 VAC/ DC | Vc: 20...60 VAC/ DC Supply voltage: 110...230 VCA | Vc: 20...60 VCAC/ DC Supply voltage: 24...48 VAC/ DC ...
Tripping current: 100, 1, 10 mA
... Current monitoring single phase; Multifunction; to 10A; Fault latch; 2 CO, Adjustable delay ...
TELE Haase Steuergeraete GmbH
Tripping current: 16 A
... Monitoring voltage relay HRN-42 Monitoring DC / AC 1-phase in 3 ranges. DESCRIPTION Monitoring voltage with 2 independent levels (overvoltage/undervoltage). MEMORY ...
Tripping current: 0.2, 4 A
Trigger voltage: 195 V - 253 V
... corresponding red LED lighting up. In the normal operation the output relay is pulled on and the power light (green LED) lights up. In the fault case as well as at loss of the supply voltage the relay drops off and the ...
Trigger voltage: 24, 115, 230, 400 V
... the hysteresis which is adjustable on the front, the relay de-energises. With inverted relay function the internal relay work the opposite way. The Voltage relay has a latch function ...
Brodersen Controls
Trigger voltage: 12 V - 24 V
... - Under voltage monitoring of generator battery - Monitors own supply - Adjustable Trip level - Adjustable Time delay - SPDT Relay output - 17.5mm wide, DIN Rail mount - UL Listed When power is applied, the ...
Tripping current: 0.15 A
Trigger voltage: 24 V
... metro and railways traction substations. Current relay CR-100 is operated by 24 V operating DC power supply and it measures the magnetic field around the busbar which passes through it. Current relay ...
Trigger voltage: 24 V - 240 V
... the input channels are protected against electromagnetic noise and overvoltage. Two output relays (Alarm-Trip): one output relay for fan control (FAN) and 1 relay for sensor failure or malfunction (TROUBLE) ABS ...
Monitoring of direct or alternating voltages in live systems. It is displayed whether the adjusted values are exceeded or not reached, and a switching process is triggered. The integrated 7-segment display indicates the sources of the ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group