- Electricity - Electronics >
- Energy: Production and Distribution >
- Three-phase transformer
Three-phase transformers
Primary current: 40 A - 250 A
Secondary current: 5 A
Frequency: 40 Hz - 60 Hz
... Measurement current transformers for currents from TAM series Modular LV analog current transformers, 2 modules width, from DIN bar for currents ...
AB TRASMISSIONI SRL
Primary voltage: 0 V - 72,500 V
Secondary voltage: 0 V - 350,000 V
... Main advantages Performance and overload Design studied to optimize any installation requirement. Silence High efficiency materials and geometry to reduce noise emission in quiet areas. Eco+POWER Expressly studied to satisfy the most stringent ...
SEA
Electric power: 1,000 W - 30,000 W
Primary voltage: 400 V
Secondary voltage: 400 V
... General Data Rated input voltage 3 x 400 Vac Rated output voltage 3 x 380 ‑ 3 x 420 Vac Rated power 1000 ‑ 30000 VA Insulation class F Maximum ambient temperature 50 °C Efficiency up to 97.5 % Degree of protection IP 00 or IP 23 Optionally adapted package ...
Primary voltage: 10, 20, 35 kV
... Overview SC (B) 10/11 epoxy cast dry-type transformer is a dry-type transformer with strong mechanical strength, electrical strength, and good heat-resistance performance. It is made of F class epoxy resin mixture with ...
Beijing SOJO Electric Co., Ltd
Electric power: 0.01 kVA - 31.5 kVA
... This TRT 33 power isolating transformer is a dry type transformer. The transformer is meant for voltage changes with galvanic isolation whenever it is necessary to change the neutral system. It is also ...
DF ELECTRIC
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
... _____ TTF transformers are used for galvanic isolation of three- phase solar installations. They are also used in the generation of ground-referenced neutrals. FEATURES _____________________________ Dry ...
POLYLUX
Output power kVA: 135 kVA
Primary voltage: 380 V
Secondary voltage: 23 V
... Product Overview: This three- phase dry-type transformer is specially designed for vacuum furnaces to achieve voltage reduction and current increase. Specific Introduction: 1. High Impedance Ensures ...
LUSHAN CHINA
... Dry-type zig zag grounding transformers are another example of Reliable Custom Transformers being built by Acutran. Neutral grounding dry-type transformers are special purpose transformers ...
Electric power: 0.1 kVA - 11.2 kVA
... according to IEC/EN 60204-1 Typical applications Voltage adjustment Generation of four-wire networks based on three-wire network Power transfer Basic equipment Separate windings Insulation class B / F from ...
... highlighted. Our three- phase transformers are constructed in accordance with vector group Yy0 unless otherwise requested. Three- Phase Transformers ...
Getra
... lowest impedance path. To influence this flow, the phase angle of the sending or receiving end must be modified – this may be done by the use of Phase Shifting Transformers. The phase ...
Smit Transformatoren
Electric power: 25 kVA - 5,000 kVA
Primary voltage: 0 V - 1,000 V
Secondary voltage: 3.3 kV - 36 kV
... Distribution transformers are used to reduce medium voltage from (3.3-36kV) to low voltage (<= 1000 V). ELTAS A.S produces oil type distribution transformers from 25 KVA to 4000 kVA. Distribution transformers ...
ELTAŞ TRANSFORMATOR San. ve Tic. A.S.
Primary voltage: 0.1 kV - 1 kV
Secondary voltage: 100 V - 120 V
Primary current: 0 A - 0.06 A
Electric power: 500 kVA - 15,000 kVA
Primary voltage: 15,000, 22,000 V
... of safety for the power distribution equipments, dry type transformer with fire resistant, non-polluting and humidity resistant features are often the right choice. AEC's cast resin transformer provides the best and safest ...
Allis Electric
Electric power: 3,000 kVA
Primary voltage: 36 kV
... Distribution Transformer Specification : Max. Manufacture voltage & capacity: 36KV & 3000KVA. Many kinds of standards are applicable: IEC, ANSI, BS, JEC, CNS… Energy Saving The importance in designing Shihlin oil-immersed distribution ...
Shihlin Electric & Engineering Corporation
Electric power: 40 W
Primary voltage: 12 V - 250 V
Primary current: 1 A
... Non-Contact Current Transformer Enhance your Smart Grid A non-contact current transformer measures three- phase current at line voltages to protect power systems and to provide critical ...
Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Frequency: 60, 50 Hz
... SummarThe 35kV transformer, the use of company-specific calculation and verification procedures, the transformer core, coils, active part, leading tanks and other components for a full range of optimized design and verification, ...
... Toroidal Transformers (TARD) can be combined with the RD family of Earth Leakage Relays to detect current leakages due to loss of ground insulation. The TARD fits on the live wires of the single, two or three phase ...
Secondary voltage: 5.5 V - 72.5 V
... epoxy resin insulated current transformers and potential transformers across the voltage range of 5.5 KV to 72.5 kV. This model JLSZV-35W outdoor combined current transformer and potential transformer ...
Output power kVA: 0.16 kVA - 16 kVA
Frequency: 50 Hz - 60 Hz
... design and manufacture JSG series three phase transformer with voltage between 160VA and 16KVA.The figure and installation size have be standardized and can be used together with 4AP series of Siemenfs. JSG ...
Shanghai Leipold Electric Co., Ltd.
Primary voltage: 110 kV
... Classification: Three dimensional wound core distribution transfor ...
Output power kVA: 0.5 kVA - 160 kVA
Frequency: 50, 60 Hz
... Three- phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These are double-wound Isolation Transformers for continuous duty and complete with earth screen ...
Boardman Transformers
Output power kVA: 3 kVA - 2,500 kVA
Primary voltage: 250 kV
Secondary voltage: 600 V
... equipment • Medical equipmentThe place where electric regulation is needed Capacity: Voltage level: 600V or below Three phase: 3~2500kVA Our series are complete and are able to customize. Features • Certificate: • ...
Riye Electric
Output power kVA: 30 kVA - 10,000 kVA
Frequency: 50, 60 Hz
... The safety and security of tamper-proof padmount transformers make them the ideal choice for installations which may be accessible by the public, or any situation where underground cabling is preferred. Maddox tamper-proof, compartmentalized, ...
Primary voltage: 3.3 kV
Secondary voltage: 3.3 kV
Frequency: 60, 50 Hz
... We manufacture three- phase power transformers in the power range 6.3kVA to 2MVA. Our selection includes Power and Eco Series, auto- transformers and electrostatically shielded transformers. ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group