ProductFor the sewage disposal of small commercially used buildings. The Wilo-Rexa UNI is suitable as an entry level model for smaller commercial buildings for sewage disposal (according to EN 12050-1). The pump can be used portable or in the pump chamber as a system solution. Vortex hydraulics with corrosion-resistant composite and smooth surface provide high reliability and universal applicability.
Advantages / Key benefits- Excellent reliability due to corrosion-free hydraulics for universal application and various fluids
- Light weight; integrated capacitor in the single-phase AC motor and flange with integrated fixation for easy installation
- Vortex hydraulics and smooth surfaces for optimum efficiency and operational reliability
- Quick maintenance facilitated by direct access to the sealing chamber and pump housing
- Longer maintenance intervals due to double seals and a large sealing chamber
Product features- Vortex hydraulics made of corrosion-free copolymer
- Motor housing made of stainless steel (available in different qualities)
- Single-phase AC motor with integrated capacitor
- Combination flange with integrated and captive fixation and flat gasket
- Hydraulics housing with integrated pump support foot
- Direct access to sealing chamber and hydraulics
DesignSubmersible pump for stationary and portable wet installation in intermittent operation.
Liquids / Applications- Sewage pumping according to EN 12050-1 (suitable for sewage disposal in small commercial buildings)
Equipment / Functions- Thermal motor monitoring with bimetallic sensor
- Single-phase AC motor with self-switching thermal motor monitoring
- Single-phase AC motor with integrated condenser
- Versions: P = with plug; A = with float switch and plug; O = bare cable ends
Type key (explanation of model code)Example: Wilo-Rexa UNI-V05B/21T006-540/O
Rexa = Submersible sewage pump
UNI = Series
V = Vortex impeller
05 = Nominal diameter of discharge port (05 = DN 50; 06 = DN 50/65)
B = Version (A = standard version, B = V4A version, K = V4A + cooling jacket)
2 = Number of poles
1 = IE-efficiency class (derived from IEC 60034-30)
T = Mains connection version (M = 1~, T = 3~)
006 = Rated power (e.g. 006 = 0.37/0.55/0.75... represented as P in kW)
5 = Mains connection frequency (5 = 50 Hz, 6 = 60 Hz)
40 = Key for rated voltage
O = Additional electrical equipment (P = with plug, A = with float switch and plug, O = bare cable end)
Delivery scope- Pump
- Installation and operating instructions
Accessories- Connection cable with fixed cable lengths (1~ motor: up to max. 30 m; 3~ motor: up to max. 50 m)
- Suspension unit for wet installation
- Level control devices
- Fixation accessories and chains
- Switchgear, relays and plugs
Logos / Certifications- Usable in hazardous area Zone 2 for specific versions
Caractéristiques / spécifications techniques- Mains connection: 1~ 230 V, 50 Hz or 3~ 400 V, 50 Hz
- Submerged operating mode: S1 (continuous), variants with intermittent modes for non-immersed use (S2/S3) depending on version
- IP rating: IP68
- Insulation class: F
- Fluid temperature: 3 … 40 °C (37 … 104 °F); max. 60 °C for up to 3 min
- Oil-filled sealing chamber with double seals (pump side: SiC/SiC; motor side: C/Cr); static seal: NBR
- Hydraulics and impeller: PP-GF30 (copolymer)
- Motor housing: stainless steel 1.4301 (AISI 304) or 1.4401 (AISI 316) depending on version (B/K/V variants)
- Versions with cooling jacket (K) available for self-cooling motors
- Typical free ball passage of hydraulics: approx. 44 mm (depending on model)
- Connection cable length typically 10 m on listed variants (check exact variant datasheet)