Climate chamber MK 720
temperaturefor rapid temperature cyclingwater condensation

Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation - image - 2
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation - image - 3
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation - image - 4
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation - image - 5
Climate chamber - MK 720 - BINDER - temperature / for rapid temperature cycling / water condensation - image - 6
Add to favorites
Compare this product

Characteristics

Type
climatic
Controlled parameter
temperature
Test type
for rapid temperature cycling, temperature stability, water condensation
Application domain
for quality control, laboratory
Configuration
reach-in
Light source
LED
Number of doors
1-door
Options and accessories
with window, touchscreen-controlled
Other characteristics
stainless steel
Capacity

734 l
(193.9 gal)

Temperature

Max.: 180 °C
(356 °F)

Min.: -40 °C
(-40 °F)

Power

8,700 W

Interior length

1,200 mm
(47.24 in)

Interior height

1,020 mm
(40.16 in)

Interior depth

600 mm
(23.62 in)

External length

1,580 mm
(62.2 in)

External height

2,005 mm
(78.94 in)

External depth

1,140 mm
(44.88 in)

Description

Product description
The BINDER MK series climatic test chamber is suitable for heat and cold tests from -40 °C to +180 °C. The MK 720 provides a compact, configurable solution for cyclic temperature testing and material conditioning.

Benefits
  • Uniform internal climate provided by APT.line™ preheating chamber technology
  • Comprehensive programming, data logging and network management
  • Heated large viewing window with LED interior lighting


Key characteristics
  • Temperature range: -40 °C to +180 °C
  • APT.line™ preheating chamber
  • Programmable condensation protection for test specimens
  • Heated viewing window with LED lighting
  • BINDER APT-COM™ Basic Edition for multi-management
  • Fault diagnosis with visual and audible alarms
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger; measurement values exportable in open format via USB
  • 2 access ports with silicone plugs, 80 mm (left and right)
  • Independent adjustable temperature safety device Class 2 (DIN 12880) with visual alarm
  • 4 castors, two with brakes
  • Adjustable ramp function and integrated chart recorder
  • Door heating, real-time clock
  • Inner chamber and 1 rack in stainless steel
  • CFC-free refrigerant R-452A; compressor cooling


Data (variants)
Article Number: 9020-0377 | 9020-0356
Designation: MK720-400V | MK720-480V-C
Option model: Standard | with voltage and frequency converter

Performance Data Temperature
Article Number: 9020-0377 | 9020-0356
Temperature range: -40...180 °C
Temperature uniformity (dependent on set value): 0.3...2.0 ± K
Temperature fluctuation (dependent on set value): 0.1...0.5 ± K
Average heating rate (IEC 60068-3-5) -40 °C to 180 °C: 4.0 K/min
Average cooling rate (IEC 60068-3-5) 180 °C to -40 °C: 4.5 K/min
Cooling time 180 °C → -40 °C: 100 min

Electrical data
Article Number: 9020-0377 | 9020-0356
Rated voltage: 400 V | 480 V
Power frequency: 50 Hz | 60 Hz
Nominal power: 8.7 kW
Unit fuse: 16.0 A
Phase (nominal voltage): 3~/N/PE (400 V) | 3~ (480 V)

Dimensions and weights
Article Number: 9020-0377 | 9020-0356
Interior volume: 734 L
Net weight (empty): 570 kg
Load per rack: 40 kg
Permitted load: 160 kg
Wall clearance back: 300 mm
Wall clearance sidewise: 200 mm

Housing dimensions (not incl. fittings and connections)
Article Number: 9020-0377 | 9020-0356
Width net: 1,580 mm
Height net: 2,005 mm
Depth net: 1,140 mm

Internal Dimensions
Article Number: 9020-0377 | 9020-0356
Interior width: 1,200 mm
Interior height: 1,020 mm
Interior depth: 600 mm
Unit doors: 1

Environment-specific data
Article Number: 9020-0377 | 9020-0356
Sound-pressure level: 65 dB(A) | 67 dB(A)
Energy consumption at 20 °C: 1,900 Wh/h

Fixtures
Article Number: 9020-0377 | 9020-0356
Number of shelves (std./max.): 1 / 11

Options, accessories & services (selection)
  • Various access ports (30, 50, 80, 100, 125 mm) left/right/top
  • Lockable door handle; compressed air connection; dry-air purge to prevent condensation
  • Notch-type access port 100 × 35 mm; calibration certificates and extended calibration packages
  • Analog output 4–20 mA; Pt100 temperature sensor (flexible); RS-485 interface
  • Racks and shelves in stainless steel; APT-COM™ software editions
  • Maintenance, qualification (IQ/OQ/PQ) and calibration services


Technical specifications
  • Model: MK 720
  • Temperature range: -40 °C to +180 °C
  • Interior volume: 734 L
  • Interior dimensions (W×H×D): 1,200 × 1,020 × 600 mm
  • Net weight (empty): 570 kg
  • Average heating rate (IEC 60068-3-5): 4.0 K/min
  • Average cooling rate (IEC 60068-3-5): 4.5 K/min
  • Cooling time 180 °C → -40 °C: 100 min
  • Temperature uniformity: 0.3...2.0 K; fluctuation: 0.1...0.5 K
  • Rated voltage options: 400 V (50 Hz) / 480 V (60 Hz)
  • Nominal power: 8.7 kW; Fuse: 16 A
  • Refrigerant: R-452A (CFC-free)
  • Permitted load: 160 kg (40 kg per rack)
  • Standard access ports: 2 × 80 mm (left and right); multiple optional sizes/positions
  • Interface: Ethernet; internal data logger with USB export; integrated chart recorder

Catalogs

No catalogs are available for this product.

See all of BINDER‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Oslo Battery Days
Oslo Battery Days

24-25 Aug 2026 Oslo (Norway)

  • More information
    LAB-SUPPLY Dresden
    LAB-SUPPLY Dresden

    8-08 Sep 2026 Internationales Congress Center (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.