Surge-relief control is achieved by "loading" the plug cavity from a regulated nitrogen source.
Features
A line pressure surge above the nitrogen "set" pressure opens the valve immediately. Transient surge pressure is thus reduced as the extra surge volume is relieved. The plug "tracks" line pressure until equilibrium is re-established and the valve closes.
Axial "straight-path" smooth flow pattern
Large annular flow area for high pressure recovery, low pressure drop, high flow coefficients
Low noise and cavitation trims available