OverviewThe DPVN1 series by CITEL is a range of Type 1+2+3 surge protective devices specifically designed for photovoltaic installations. Based on CITEL's patented CTC technology, the DPVN1 integrates a thermosensitive separation point at the core of the SPD to ensure the safest disconnection available. Devices are DIN-rail mountable, compact and fitted with a visual failure indicator for straightforward installation and maintenance.
Key features- Combined SPD Type 1+2+3 for PV systems
- CTC Technology (thermosensitive separation)
- Discharge capacity per pole: Iimp/total = 6.25/12.5 kA (10/350 µs); In/total = 15/60 kA (8/20 µs)
- Safe disconnecting device with mechanical indicator
- Fault-resistant Y-circuit
- Remote signaling via changeover contact
- Compliance: IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.5
- Certified: IEC 61643-31 / EN 61643-31
Electrical PropertiesSPD type: 1+2+3
Network: PV 1000 Vdc
Nominal PV voltage (Uocstc): 1000 Vdc
Max. PV operating voltage (Ucpv): 1200 Vdc
Residual current (Ipe) - leakage to ground: < 0.2 mA
PV permanent operating current (Icpv): < 0.1 mA
Follow current: None
Nominal discharge current (In) - 15 impulses 8/20 µs: 20 kA
Max. discharge current per pole (Imax) - 8/20 µs: 40 kA
Total max. discharge current (Imax Total) - 8/20 µs: 60 kA
Impulse current per pole (Iimp) - 10/350 µs: 6.25 kA
Total lightning current (Itotal) - 10/350 µs: 12.5 kA
Combination waveform withstand (IEC 61643-11) Uoc: 6 kV
PV short-circuit current withstand (Iscpv): 15 000 A
Connection mode(s): +/-/PE
Protection mode(s): Common / Differential
Protection level +/- @ In (8/20 µs) (Up): 4.3 kV
Protection level +/PE (-/PE) @ In (8/20 µs) (Up): 4.3 kV
Protection level at 5 kA (8/20 µs) (Up): 3.6 kV
Mechanical PropertiesTechnology: MOV
Connection: Screw terminals 2.5-25 mm² (35 mm²) / busbar
Compact monobloc format
Plugable: No
Mounting: Symmetrical DIN rail 35 mm (EN 60715)
Housing material: Thermoplastic UL94 V-0
Operating temperature: -40 / +85 °C
Protection rating: IP20
Outdoor application: No
Failsafe mode: All-pole disconnection from PV network
Disconnection indicator: 1 mechanical indicator - Red/Green
Remote signaling: Output on changeover contact
Max. voltage/current for remote signaling: 250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions: see diagram - 2.5TE (EN43880)
Weight: 0.433 kg
Norms & CertificationStandards compliance: IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification: KEMA
DeconnectorThermal disconnector: CTC Technology integrated
Back-up protection device: Without
Schematics & DiagramsElectrical and mechanical diagrams are provided for the product.
Specifications- Model: DPVN1-6CS-21Y-1200
- Product code: 65212102
- SPD type: 1+2+3
- Nominal PV voltage: 1000 Vdc
- Max. PV operating voltage: 1200 Vdc
- Nominal discharge current (In): 20 kA (8/20 µs)
- Max. discharge current per pole (Imax): 40 kA (8/20 µs)
- Total max. discharge current: 60 kA (8/20 µs)
- Impulse current per pole (10/350 µs): 6.25 kA
- Total lightning current (10/350 µs): 12.5 kA
- Protection level Up @ In (8/20 µs): 4.3 kV
- Connection modes: +/-/PE
- Protection modes: Common and Differential
- Follow current: None
- Leakage current to ground: < 0.2 mA
- Operating temperature: -40 / +85 °C
- Mounting: DIN rail 35 mm
- Housing: Thermoplastic UL94 V-0
- IP rating: IP20
- Weight: 0.433 kg