video corpo

Diesel generator set QSX15
three-phasestationary50 Hz

Diesel generator set - QSX15  - CUMMINS GENERATOR TECHNOLOGIES - three-phase / stationary / 50 Hz
Diesel generator set - QSX15  - CUMMINS GENERATOR TECHNOLOGIES - three-phase / stationary / 50 Hz
Add to favorites
Compare this product

Characteristics

Motor type
diesel
Phase
three-phase
Portability
stationary
Frequency
50 Hz, 60 Hz
Fuel System
direct fuel injection
Cooling system
air-cooled
Applications
industrial
Options and accessories
soundproof, EU IIIA emissions-compliant
Emissions level
Stage II, Tier 2
Power in kVA

364 kVA, 400 kVA, 569 kVA, 625 kVA
(494.9 hp, 543.85 hp, 773.62 hp, 849.76 hp)

Rated capacity

291 kW, 320 kW, 455 kW, 500 kW
(395.6 hp, 435.1 hp, 618.6 hp, 679.8 hp)

Rotational speed

1,800 rpm
(11,310 rad.min-1)

Width

1,500 mm, 1,553 mm
(59.1 in, 61.1 in)

Height

2,066 mm, 2,447 mm
(81.34 in, 96.34 in)

Weight

4,130 kg, 5,363 kg, 5,580 kg
(9,105.09 lb, 11,823.39 lb, 12,301.79 lb)

Description

Overview
  • Engine family: QSX15 — industrial 4-cycle diesel engine designed for commercial and industrial generator sets, delivering regulated power with low emissions and fast load response.
  • Alternator options: multiple alternator sizes with selectable motor starting capability, low-reactance 2/3 pitch windings and low waveform distortion with non-linear loads.
  • PMG option: permanent magnet generator available to enhance motor starting and short‑circuit fault clearing capability.
  • Control system: PowerCommand® electronic control provides system integration including automatic remote start/stop, precise frequency and voltage regulation, alarm and status display, AmpSentry™ protection, output metering, auto-shutdown on fault and NFPA 110 Level 1 compliance.
  • Cooling: standard integral set‑mounted radiator system engineered and tested for rated ambient temperatures.
  • Enclosures and fuel tanks: optional weather-protective and sound-attenuated enclosures; optional dual-wall sub-base fuel tanks.
  • Certifications and availability: configurations available to meet EPA Tier 2 and EU Stage II; regional availability across Africa & Middle East, Asia Pacific, Europe, India, Latin America and North America.


Highlights
  • Frequency: 50 Hz and 60 Hz
  • Certification: EPA Tier 2, EU Stage II (configuration dependent)
  • Typical applications: Prime, Standby, Data Center Continuous
  • Regional availability: Africa & Middle East, Asia Pacific, Europe, India, Latin America, North America


Rated for (kW / kVA) - summary table
  • Prime: 291 – 455 kW | 364 – 569 kVA
  • Standby: 320 – 500 kW | 400 – 625 kVA
  • Data Center Continuous: 410 – 455 kW | 563 – 569 kVA


Generator models (selected rows)
  • C400 D5e — 50 Hz — Prime 291 kW / 364 kVA — Standby 320 kW / 400 kVA — Diesel — EU Stage II
  • C450 D5e — 50 Hz — Prime 327 kW / 409 kVA — Standby 360 kW / 450 kVA — Diesel — EU Stage II
  • C500 D5 / C500 D5e / C500 D6 — 50 Hz — Prime ~360–364 kW / 450–455 kVA — Standby 400 kW / 500 kVA — Diesel
  • C550 D5 / C550 D5e — 50 Hz — Prime 400 kW / 500 kVA — Standby 440 kW / 550 kVA — Diesel
  • C450 D6e / C450 D6 / C500 D6 (60 Hz) — Prime ~409–455 kW / ~511–568 kVA — Standby up to 500 kW / 625 kVA — Diesel — EPA Tier 2 (selected rows)
  • DFEK / DFEJ — 60 Hz — Prime 455 / 410 kW | 569 / 513 kVA — Standby 500 / 450 kW | 625 / 563 kVA — Data Center Continuous where specified — Diesel — QSX15-G9 NONROAD 2 on selected configurations — Wide regional availability


Notes
  • Power ranges and ratings vary by generator model and selected application (Prime, Standby, Data Center Continuous).
  • Multiple configurations exist to match regional certification and application requirements.


Technical specifications
  • Engine family: QSX15 (Cummins® industrial diesel)
  • Control: PowerCommand® electronic control with remote start/stop, frequency and voltage regulation, alarms, AmpSentry™ protection, output metering and NFPA 110 Level 1 compliance
  • Alternator options: selectable sizes, low-reactance 2/3 pitch windings, low waveform distortion, short-circuit fault clearing capability
  • PMG: permanent magnet generator option for enhanced motor starting and fault clearing
  • Cooling: integral set-mounted radiator system rated for specified ambient temperatures
  • Enclosures: optional weather-protective and sound-attenuated enclosures
  • Fuel tanks: optional dual-wall sub-base tanks
  • Frequencies: 50 Hz and 60 Hz
  • Certifications: EPA Tier 2, EU Stage II (configuration dependent)
  • Fuel type: Diesel
  • Regional availability: Africa & Middle East, Asia Pacific, Europe, India, Latin America, North America

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

InnoTrans 2026
InnoTrans 2026

22-25 Sep 2026 Berlin (Germany) Hall 18 - Stand 380

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.