Product descriptionThe W519-DCH10 is an online free chlorine analyzer fitted with a German-imported CH10 sensor using a coated dual-electrode constant-current method. It provides continuous residual free chlorine monitoring for process and industrial waters and includes automatic temperature compensation, resistance to surfactants and fouling, and a sealed IP65 enclosure with cast aluminum lower housing and PA66+30GF top cover.
Application- Fruit and vegetable disinfection
- Process water
- Industrial process water
Key Features- Coated dual-electrode constant-current CH10 sensor (German-imported)
- Resistant to surfactants and fouling
- Built-in automatic temperature compensation for improved accuracy
- No zero calibration required; calibration interval ≤ 3 months
- Wide measurement range options (up to 20% or up to 2000 mg/L)
- Two input signal interfaces for auxiliary parameters (pH, ORP, conductivity, turbidity, dissolved oxygen)
- Multiple output options: 4–20 mA and RS485 (MODBUS)
- Supports wall, panel or pipe-clamp mounting
- Aluminum alloy / PA66+30GF housing, protection class IP65
Technical parametersMeasurement Parameter: Free Chlorine
Measurement Range: 20 - 2000 mg/L; 0.05 - 20%
Lower Detection Limit: 20 mg/L (depending on range)
Resolution: 1 mg/L (depending on range)
Response Time: T90 ≈ 8 minutes
pH Range: 5.0 ~ 8.0
Maintenance: Membrane cap replacement cycle: ~1 year (depending on water quality)
Flow Rate: In flow cell: 250 ~ 500 mL/min
Operating Temperature: 0 ~ 45℃
Display: LCD screen
Power Supply: 105 ~ 235 VAC, 50±1 Hz / 24 VDC ±5 (DC optional)
Analog Output: Two analog outputs (load resistance <500Ω)
Digital Output: RS485 interface, MODBUS RTU protocol
Relay Output: Three relays, 5A 250VAC, 5A 30VDC
Material: Bottom case: Cast aluminum with spray coating; Top cover: PA66+30GF with spray coating
Dimensions: 145145174mm (HWD)
Protection Class: IP65
Certification: CE, RoHS, REACH (sensor)
Technical specifications- Model: W519-DCH10
- Sensor: German-imported CH10 free chlorine sensor, coated dual-electrode constant-current method
- Measurement ranges available: up to 2000 mg/L or up to 20%
- Lower detection limit: 20 mg/L (range dependent)
- Resolution: 1 mg/L (range dependent)
- Response time: T90 ≈ 8 minutes
- pH operating range: 5.0–8.0
- Membrane cap replacement: ~1 year (depending on water quality)
- Flow cell inlet rate: 250–500 mL/min
- Operating temperature: 0–45℃
- Display: LCD
- Power supply options: 105–235 VAC 50±1 Hz or 24 VDC ±5 (DC optional)
- Outputs: two analog outputs (4–20 mA), RS485 MODBUS (MODBUS RTU)
- Relays: three relays (5A 250VAC, 5A 30VDC)
- Housing: cast aluminum bottom case with spray coating; PA66+30GF top cover with spray coating
- Protection class: IP65
- Certifications: CE, RoHS, REACH (sensor)