Daygas brings together efficient, economical, quality and functional products that give importance to innovation and R&D studies, thus saving energy in the heating sector, with final consumers.Quick start-up.Frost protection.Low emission ratio.High level of safety.Safe gas valve system.Low energy consumption.Simple service and assembly.Heat resistant non-flammable cable.Two types of tubular: Radium I and U.2 or 5 stage with thermostats or remote control.Warm up by radiation without air ventilation.Notification of fault and stage on the display screen.Capacity30 kWGas ConsumptionNG 2.85 m³/h / LPG 2.11 kg/hDimensions250h / 7200-10200L / 405wWeightNet 120-175 kg / Gross 150-220 kgOperating Pressure21-55 mbar NG / 32-55 mbar LPGInstallation On Height260-470 cmElectrical Connection230-240VAC 50-60Hz +/-15%Gas ConnectionG ¾’’Radium Tube Radiant HeatersDaygas Radium tube type radiant heaters are modern devices designed to heat high ceilings and large volumes. Radium warms the atmosphere by reflecting the heat energy generated by the combustion of the air-gas mixture inside the radiant tubes into the desired environment thanks to parabolic design aluminum reflectors. Radium tube type radiants heat people and objects, ensuring optimal comfort for heating.The tubular radiant heaters use heat treated aluminum steel fillet tubes.With pipes, efficient, low capacity, efficient heating is provided to end users.Fillet tubes are designed for high performance aluminas. These pipes are made of calorized steel coils to your aluminum.From raw to finished pipe, the production process is subject to special processes to show the highest radiation capability in the areas of use.Heat Dissipation & EfficiencyRadium tube radiant device adjacent temperature distribution isohips curve Y.I.B the ability to address a large area, as in the curve, is due to the high radiant efficiency of the radiant tube material to radiate. Steel-specific radiant tubes to aluminum, with a radiant efficiency of 92%. High efficiency is achieved by minimizing heat losses.Importance Of Tube On Piped Radiant DevicesThe flame, created by the air-fuel mixture in the burner, flows through the pipe into the chimney gas and the waste gas is expelled. During this process, the energy generated by the burning gas in the pipe is transmitted to the pipe. Heating is ensured by the pipe emitting its energy by radiating to the environment. Therefore, the maximum heat transfer and radiation capability is directly related to the quality and suitability of the fillet tube.Reflectors of Radium Radiant HeatersThe radiation beams coming out of the pipe surface area are indicated by red color (straight line), the beams reflected from the reflector are indicated by orange (dashed line). The choice of reflector material is crucial; reflective aluminum material with high reflective properties is used in these products. Reflectors are used to redirect radiation from dead spots (usually the part facing the ceiling) back to the desired environment, increasing the radiation capacity.Device ControlsRemote control.Integration via control board.Pako switched manual control.Thermostat-switched automatic control.Integration into the automation system (Control via Scada).The variety of control scenarios allows the products to be managed correctly and as desired. The most appropriate control scenario is selected by evaluating the on-site use and site conditions. Proper control facilitates both fuel savings and long-lasting, trouble-free service.Control Panel FeaturesPassword protection.Heat preservation mode.Freeze protection feature.24/7 programmable feature.128 x 64 graphic LCD display.Communication port with computer.Automatic and manual control.Ability to connect external temperature sensor.Control up to 8 independent zones and 32 devices in total.Analog Room ThermostatAutomatically turns off the device when the set temperature is reached, and restarts when the temperature drops below the desired value, saving fuel.Temperature SensorFreeze protection mode.Modulating control.Temperature adjustment via the device.When the programmed temperature is approached, the device reduces modulation value to save fuel. When the environment reaches the desired temperature, the device shuts down, and restarts as needed.Pako Switched Manual ControlStep-adjusted manual control via the pako switch. For local solutions where no control panel is needed, devices can be operated at the desired level via the pako switch. Heaters can be controlled with an independent step setting. When powered off, the device goes to sleep after closing procedures, ensuring long service life.Remote ControlSimple-to-use device with 3 buttons for on-off, heat setting, and reset. All Daygas products can be controlled remotely with a single remote.Technical Specifications / FeaturesCapacity: 30 kWGas Consumption: NG 2.85 m³/h / LPG 2.11 kg/hDimensions: 250h / 7200-10200L / 405wWeight: Net 120-175 kg / Gross 150-220 kgOperating Pressure: 21-55 mbar NG / 32-55 mbar LPGInstallation Height: 260-470 cmElectrical Connection: 230-240VAC 50-60Hz +/-15%Gas Connection: G ¾’’Quick start-up, frost protection, low emission, high safety, safe gas valve, low energy consumption, simple service and assembly, heat resistant non-flammable cable, two types of tubular (I and U), 2 or 5 stage with thermostats or remote control, radiation heating without air ventilation, fault and stage notification on display.