Current repeater D5072D-087
SIL 2for hazardous areas

Current repeater - D5072D-087 - GM International S.p.A. - SIL 2 / for hazardous areas
Current repeater - D5072D-087 - GM International S.p.A. - SIL 2 / for hazardous areas
Add to favorites
Compare this product

Characteristics

Options
current, for hazardous areas, SIL 2

Description

The Resistance Repeater D5072-087 accepts a resistance/RTD or transmitting potentiometer sensor, located in Hazardous Area, and repeats the resistance, with isolation, to Safe Area, suitable for applications requiring SIL 2 level in safety related systems for high risk industries.SIL 2 / SC 3Input from Zone 0/Div. 1Installation in Zone 2/Div. 22/3/4wire res./RTD or potentiometer inputBurnout Fault detectionFully programmable operating parametersHigh AccuracyThree port isolation, Input/Output/SupplyHigh Density, two channels per unitTechnical DataSupplyVoltage24 Vdc nom (18 to 30 Vdc), reverse polarity protectedCurrent Consumption37 mA @ 24 Vdc with 1 mA excitation current, typical.Power Dissipation0.9 W @ 24 Vdc with 1 mA excitation current, typical.InputType2-3 wire Resistance or 2 transmitting pot.Integration timefrom 50 ms to 500 ms.Input range0 to 4 kΩ.Measuring RTD current≤ 0.15 mA.OutputType2-3 wire resistanceTransfer characteristiclinear, scaled or custom.Response time10 to 90 % step: ≤ 10.0 ms (slow), ≤ 1.2 ms (fast).Output range0 to 400 Ω.Excitation current0.1 to 10 mA.FaultTypeBurnout / Internal fault. Output reflects fault condition via highscale (450 Ω) value forcing. Fault condition is also signaled via BUS and red LED on front panel.Input to out performanceRef. Conditions24 V supply, 23 ± 1 °C ambient temperature, slow integration mode, 3 wires configuration for RTD, input/output range 10 to 400 Ω.Calibration and linearity accuracy≤ 200 mΩ typical (Excitation Current ≥ 1 mA); ≤ 300 mΩ typical (0.5 mA ≤ Excitation Current Temp. influence± 20 mΩ/°C, typical (Excitation Current ≥ 1 mA).IsolationTest VoltageI.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.Environmental conditionsOperating temperaturetemperature limits –40 to +70 °CStorage temperaturetemperature limits –45 to +80 °C.Safety descriptionEquipmentAssociated apparatus and non-sparking electrical equipment.Safety parametersUo = 7.2 V, Io = 16 mA, Po = 27 mW, Ui = 12.8 V, Ci = 0 nF, Li = 0 nH at terminals 7-8-9, 10-11-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.MountingTypeDIN-Rail 35 mm, with or without Power Bus.Weightabout 135 gConnectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.Status: ACTIVEChannels: 2Certifications:ATEX, IECEx, EMC, Ex, Maritime, Metrological, SIL certificates available (see documentation links).
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.