Current repeater X1-NIS-DI-01-S
ATEXDIN rail

Current repeater - X1-NIS-DI-01-S - GM International S.p.A. - ATEX / DIN rail
Current repeater - X1-NIS-DI-01-S - GM International S.p.A. - ATEX / DIN rail
Add to favorites
Compare this product

Characteristics

Options
current, DIN rail, ATEX

Description

The Switch/Proximity Detector Repeater X1-NIS-DI-01 is a module suitable for applications requiring SIL 3 level in safety related systems for high risk industries. The unit can be configured for switches or proximity detectors, and repeats the input state to an open-collector transistor in Safe Area. The selectable fault detection circuit is available for proximity sensors or switches equipped with end-of-line resistors. When selected, the fault drives the common line and forces the output open. Input to output function can be inverted. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.SIL 3 / SC 3Installation in Zone 2 / Division 2Loop disconnection to ease maintenance operationsHigh frequency transistor outputField open and short circuit detection (DIP switch programmable)Inverted output available (DIP switch programmable)Three port isolation, Input/Output/SupplyStatus: ACTIVEChannels: 1Technical DataGeneralPower Dissipation0.46 W @ 24 Vdc with short circuit input and 100 mA output current, typical.System SupplyVoltage24 Vdc nom (18 to 30 Vdc).Current Consumption15 mA @ 24 Vdc with short circuit input and closed output, typical.System OutTypeVoltage free SPST optocoupled open-collector transistor. When input diagnostics is active, System Out opens.Max voltage35 Vdc.Max current50 mA.Max voltage drop1.5 V @ 50 mA.Leakage current≤ 50 μA @ 35 Vdc.Response time≤ 500 μs.Frequency response1 kHz maximum.Field InTypeVoltage source according to NAMUR standard.Input equivalent source8 V/1 kΩ typical (8 V no load, 8 mA short).Input switching current levelsON ≥ 2.1 mA, OFF ≤ 1.2 mA.No Faultinput current ≥ 0.35 mA and input resistance ≥ 360 Ω.Open Faultinput current ≤ 0.05 mA.Short faultinput resistance ≤ 100 Ω.FaultTypeField sensor fault is available on the common fault line, when input diagnostics is active.IsolationTest VoltageField In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.Environmental conditionsOperating temperaturetemperature limits –40 to +70 °C.Storage temperaturetemperature limits –45 to +80 °C.Safety descriptionEquipmentAssociated apparatus and non-sparking electrical equipment.Safety parametersUo = 10.5 V, Io = 11 mA, Po = 29 mW at terminals A-Z Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.MountingTypeOn custom Termination Board.Weightabout 55 g.DimensionsWidth 10 mm, Depth 80 mm, Height 120 mm.Certifications:ATEX: FM ATEX zone 2 X1 Series English Certificate (Europe) FM23ATEX0039X, FM, 2025-08-13Ex: FM US X1 Series Divisions and Zones English Certificate (North America) FM23US0073X, FM, 2025-08-12Ex: FM Canada X1 Series Divisions and Zones English Certificate (North America) FM23CA0055X, FM, 2025-08-12IECEx: FM IECEx X1 Series English Certificate (International) IECEx FMG 23.0018X, FM, 2025-08-12SIL: TUV IT 25 SIL 0529 A SIL Certificate Summary (International) TUV IT 25 SIL 0529 A Rev.1, TUV_SUD, 2025-09-19UKEx: FM UKEx zone 2 X1 Series English Certificate (United Kingdom) FM23UKEX0040X, FM, 2025-08-14Declarations of Conformity:EU Declaration of Conformity of X1-NIS-DI-01UK Declaration of Conformity of X1-NIS-DI-01Characteristics / Technical Specifications:Product: X1-NIS-DI-01-SChannels: 1Power Dissipation: 0.46 W @ 24 VdcSystem Supply Voltage: 24 Vdc nom (18 to 30 Vdc)Current Consumption: 15 mA @ 24 VdcOutput: Voltage free SPST optocoupled open-collector transistorMax Output Voltage: 35 VdcMax Output Current: 50 mAResponse Time: ≤ 500 μsFrequency Response: 1 kHz maxInput: Voltage source according to NAMUR standardOperating Temperature: –40 to +70 °CStorage Temperature: –45 to +80 °CMounting: On custom Termination BoardWeight: about 55 gDimensions: 10 x 80 x 120 mm

Catalogs

No catalogs are available for this product.

See all of GM International S.p.A.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.