Product ApplicationThis cable meets standards such as GB 50311, ISO/IEC 11801 and ANSI/TIA-568.2-D and is defined up to 350 MHz to cover Class E/Cat.6 applications. It is designed for transmission of voice, data and digital or analog audio/video signals in Class E systems.
GeneralCategory 6 copper data cable with cross-shaped spacer and overall foil/braid shielding (F/UTP) to reduce external electromagnetic interference and pair crosstalk. Available with FR/PVC, FRNC/LSOH or GB/B1 flame-retardant outer sheaths. Compatible with connectors per GB 50311 and ISO/IEC 11801.
Product Performance- Transmission bandwidth: 250 MHz (extended definition to 350 MHz)
- Conductor resistance (20 °C): 93.8 Ω/km
- Capacitance: ~42 pF/m
- Characteristic impedance: 100 ± 5 Ω
- Nominal velocity of propagation (NVP): ~68%
- Tensile strength: ≤ 110 N
- Bending radius: pull ≥ 58 mm; fixed ≥ 28 mm
- Temperature range: installation 0 °C to +50 °C; operating -20 °C to +60 °C
- Halide emission standards: GB/T 17650.1, GB/T 17650.2, IEC 60754-1/-2
- Flame spread standards: GB/T 18380.12, IEC 60332-1, GB 31247
- Smoke density standards: GB/T 17651, IEC 61034-1/-2
Order Information (examples)Product Model | Product Description | Outer Diameter | Color | Unit
TDX60A-FNU4PVL-GYRA | TDX60A Shielded Twisted Pair Cat.6, FR/PVC | 7.3 mm | Gray | 305 m/box
TDX60A-FNU4PZL-BURA | TDX60A Shielded Twisted Pair Cat.6, FRNC/LSOH | 7.3 mm | Blue | 305 m/box
TDX60A-FNU4PBE-BURA | TDX60A Shielded Twisted Pair Cat.6, GB/B1 | 7.6 mm | Blue | 305 m/box
Technical specifications- Model (commercial name): TDX60A
- Category: Class E / Cat.6 (extended to 350 MHz)
- Construction: 4P shielded twisted pair, cross-shaped spacer with overall shielding (F/UTP)
- Conductor size: AWG23
- Outer sheath options: FR/PVC, FRNC/LSOH, GB/B1 flame-retardant variants
- Outer diameters (examples): 7.3 mm, 7.6 mm
- Packing: typically 305 m per box
- Electrical: characteristic impedance 100 ± 5 Ω; NVP ~68%; capacitance ~42 pF/m; conductor resistance ~93.8 Ω/km (at 20 °C)
- Mechanical: tensile strength ≤ 110 N; bending radius: pull ≥ 58 mm, fixed ≥ 28 mm
- Temperature: installation 0 °C to +50 °C; operating -20 °C to +60 °C
- Standards & compliance: GB 50311, ISO/IEC 11801, ANSI/TIA-568.2-D; IEC 60332-1; halide and smoke tests per GB/T 17650.x, IEC 60754-x, GB/T 17651, IEC 61034
- Applications: voice, data, digital and analog audio/video transmission for Class E systems