OverviewThe Kobold PAD differential pressure transmitter is a microprocessor-based instrument for measuring differential, gauge or absolute pressure. It offers flexible calibration and output configuration, automatic compensation for ambient temperature and process variables, and communication via HART®. The PAD is available optionally as a flow meter (PAD-F) with totalising and frequency output options.
Highlights- Measurement modes: differential, gauge, absolute
- High accuracy: ±0.075 % of calibrated span
- Large span ratio: 100:1
- Continuous self-diagnostics and automatic ambient temperature compensation
- Materials: stainless steel (316L), Hastelloy-C®, Tantalum, Monel
- Protection: IP67; explosion-proof enclosures available
Applications- Process pressure measurement
- Flow measurement by differential pressure (PAD-F option)
- Tank and level measurement
Key features- 2-wire 4–20 mA output with HART® communication; linear or square-root output
- Optional frequency (pulse) output with selectable pulse width
- Configuration via handheld terminal or PC; parameters stored in EEPROM
- Measuring diaphragm materials: 1.4404 (316L), Monel, Tantal, Hastelloy-C
- Display: 5-digit LCD; mounting bracket for 2" pipe
- Explosion-proof housing options and multiple process connection adapters
Technical data- Measuring span: 0.75 mbar–413.70 bar (depending on version)
- Accuracy: ±0.075 % of set measuring span
- Span ratio: 100:1
- Process temperature range: -40 °C to +120 °C
- Ambient temperature range: -40 °C to +80 °C
- Storage temperature range: -40 °C to +85 °C
- Power supply: 11.9–45 VDC (17.4–45 VDC with HART®)
- Max. load: 250 Ω at 17.4 VDC, 550 Ω at 24 VDC
- Process connections: 1/4-18 NPT i (optional 1/2-14 NPT oval adapter)
Wetted parts and construction- Measuring diaphragm: 1.4404 (316L), Monel, Tantal, Hastelloy-C
- Filling fluid: silicone oil or inert filling liquid
- Electronics housing: die-cast aluminium; flameproof Ex "d" option
- Protection class: IP67
- Finish: epoxy-polyester or polyurethane
Certifications & communication- ATEX options available (Ex II 2G Ex d IIC T6…T5, Ex ia options)
- Communication: HART® protocol
Model- Model: PAD (PAD-F option for flow measurement with totaliser and frequency output)