Double output signal, level and temperature
Measuring range of level 5, 10, 20 mH2O
Temperature measuring range of 0°C…60℃
Quick connection by connector M12 5Pts to data loggers LOGV3 by 4-20 mA
Battery powered logger, low power consumption, autonomy > 5 ans
Rugged and compact
Integrated atmospheric pressure aerator
Wireless configuration
Communication (depending on the logger model) : HF / GSM / GPRS / 3G / SIGFOX
IP68 protection
Pressure level sensors also providing temperature (Pt1000). Easy to install with their 4-20mA output, and M12 8PTS connectors to the LOG V3 dataloggers. Data retrieval is done by radio on-site, or remotely by GSM/GPRS for compatible loggers.
Logger - 500 000 measures
Data access point - Oui
Radio communication - 100M open field (Wiji protocol)
HF / GSM antenna - ¼ longueur d’onde/ GSM
Temperature range
- -40 …85°C
Housing - PA12
Sealing grade - IP67
Energy
- Lithium Bat : 3,6V 34Ah
Configuration
- Configuration kit PN : MOC00001(868 MHz) or MOC00002(915 MHz).
Both integrate the software AVELOUR 6 for the configuration and data analysis
Net weight
- 195g
Measuring range of
Level - 5, 10, 20 mH2O
Pressure type - Relative
Measuring range of
temperature - 0…60℃
Overpressure - 1,5 x FS
Accuracy - ±0.5% full scale (Level)
±2℃ (temperature)
Output signal
Supply voltage - 4 ~ 20 mA (level and temperature)
Min 12 – Max 30 VDC
Operating Temperature - Normal : -10 … 70°C
Maxi : -20… 85°C (Storage)
Stability - ±0.2% full scale/year/td>
Zero thermal drift - ±0.02% full scale/℃
Housing - Diaphragm : stainless steel 316L
Body : stainless steel 1Cr18Ni9Ti
Cable : Polyethylene