Characteristics

Technology
fluxgate
Mounting
PCB, plug-in
Electrical characteristics
AC, DC, three-phase, differential
Other characteristics
through-hole, high-accuracy, leakage, monitoring, RCD, high-sensitivity
Output
with electrical output signal, IoT
Primary current

Max.: 100 mA

Min.: 3 mA

Description

MD0630T01A-2 is an automotive grade ultra-small leakage current sensor designed for portable charger also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, earth leakage detector and differential current sensor. Dedicated to detect to Type AC, A, F, B and B+ leakage current measurement. The internal parts of the portable charger should be as small as possible, our new leakage detector is small and lightweight, which just meets this requirement. This residual current monitor will detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs. In electric vehicle charging if the DC fault current is greater than 6mA, it could change the characteristics of a Type A RCD due to its core saturation, resulting in the type A failing to trip and a lack of detection of the DC fault. In this instance, the risk of electric shock is increased, and safety is compromised. IVY has launched a new 6mA DC sensor that is designed to detect a DC earth fault, which is more cost-effective than using a Type B RCCB. In the event of a dangerous electrical fault, the sensor will output an alarm signal (by setting the leakage alarm value). This new 6mA DC sensor enables compliance with the updated IEC62955:2018 and reduces the cost of developing electric vehicle charging solutions.