- Detection - Measurement >
- Electrical Measurements >
- DC current sensor
DC current sensors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 80, 40 A
... residual current sensors to avoid hazardous situations in cases where the vehicle battery ( DC) is connected to the home power supply (AC). Generally, AC/ DC sensitive residual current ...
BENDER GmbH & Co KG
Primary current: 0 A - 40 A
... residual current sensors to avoid hazardous situations in cases where the vehicle battery ( DC) is connected to the home power supply (AC). Generally, AC/ DC sensitive residual current ...
BENDER GmbH & Co KG
Primary current: 80, 40 A
... residual current sensors to avoid hazardous situations in cases where the vehicle battery ( DC) is connected to the home power supply (AC). Generally, AC/ DC sensitive residual current ...
BENDER GmbH & Co KG
Primary current: 20, 19 mA
... Honeywell CSLA series linear current sensors incorporate our 91SS12-2 and SS94A1 linear output Hall effect transducter (LOHET™). The sensing element is assembled in a printed circuit board mountable housing. This housing ...
Primary current: 0.5 A - 600 A
... Transformer
for DC
Current Chauvin Arnoux type PAC16
- Current clamp for DC current
- Push button for zero setting
- Switch
... Sensor ø28mm for Type B Earth Leakage Relays B series sensors are able to measure AC and DC currents with a DC-10kHz bandwidth, and 1mA resolution. ...
FRER
... Sensor ø60mm for Type B Earth Leakage Relays TDB series sensors are able to measure AC and DC currents with a DC-10kHz bandwidth, and 1mA resolution. ...
FRER
... Sensor ø90mm for Type B Earth Leakage Relays TDB series sensors are able to measure AC and DC currents with a DC-10kHz bandwidth, and 1mA resolution. ...
FRER
Primary current: 1,000 A
... Measuring range [A] 1000 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split coreMounting Conductor rail mounted Opening diameter [mm] 6.5 mm, ...
Angst+Pfister Sensors and Power AG
Primary current: 300 A
... Measuring range [A] 300 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split core Mounting Conductor rail mounted Opening diameter [mm] 9.5 ...
Angst+Pfister Sensors and Power AG
Primary current: 600 A
... Measuring range [A] 600 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split core Mounting Conductor rail mounted Opening diameter [mm] 9.5 ...
Angst+Pfister Sensors and Power AG
Primary current: 2 mA - 100 mA
... Leakage Current Sensors for EV Charging Fully Compliant with DC and AC Leakage Current Detection Standards This device can detect 6mA DC and 20/30mA ...
IVY METERING
Primary current: 2 mA - 15 mA
... Residual current detection options for IEC based requirements are 30mA AC & 6mA DC or 20mA AC & 6mA DC for UL requirements. It can not only detect AC ...
IVY METERING
Primary current: 3 mA - 100 mA
... sensititivity AC DC leakage current sensor for solar inverter residual current detection, which can also be called residual current ...
IVY METERING
Primary current: 50 A - 600 A
... MAP4- DC measurement unit (for DC current)
Primary current: 300 A
... The DC Hall effect current sensor is a current sensor made by using the open-loop Hall effect. The primary and secondary are completely insulated. It is mostly utilized ...
Primary current: 250 A
... leakage relays are used to measure both AC and DC leakage currents. Thanks to its advanced technology and the quality of the materials components used, the differential toroid can be used to detecte ...
ZELEC
Primary current: 250 A
... leakage relays are used to measure both AC and DC leakage currents. Thanks to its advanced technology and the quality of the materials components used, the differential toroid can be used to detecte ...
ZELEC
Primary current: 400 A
... leakage relays are used to measure both AC and DC leakage currents. Thanks to its advanced technology and the quality of the materials components used, the differential toroid can be used to detecte ...
ZELEC
Primary current: 0.01 A - 0.1 A
... SCD1 series DC Leakage Current Sensor is the current sensor which develop on base of magnetic modulation closed loop principle, apply unique patented ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 100 A
... effect current sensors for DC and AC, Pulse current measurement in PCB and panel mount versions. This SCK28 series is a open loop current sensor ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 75 A - 1,000 A
... SCY15C Series open loop current sensor is develop on basis of Hall effect. It is especially designed for the electronic measurement of DC, AC or pulsed currents in high ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 0 A - 200 A
... • Accurate and High Resolution • 23 mm Conductor Diameter • One Touch Zero ...
Primary current: 0 A - 40 A
... Accurate DC/AC current probe for current measurement. • 1mDCA high resolution on 4A DC range. • 0.1mACA high resolution on 400mA AC range • One touch zero for DCA ...
... Consistent, high-precision current testing across a wide temperature range Hioki AC/ DC clamp sensors are best-in-class current sensors for use with power ...
Primary current: 500, 1,000, 2,000 A
... AC/ DC CURRENT SENSOR CT6877 Raising the Bar for High-Accuracy Measurement Overview Hioki pass-through AC/ DC current sensors are best-in-class ...
Primary current: 50, 100 A
... extremely easy. The sensors are available with different levels of primary rated current and output signals. They are ideal to be connected with the QE- CURRENT-485 universal current ...
Primary current: 5 A - 2,500 A
... TSC200 is a 1-Wire current sensor with 0.3 to 15A working range and IP30 protection. TSC200-15 is a galvanic isolated 1-Wire current sensor. The sensor provides a low-cost ...
Primary current: 1 mA - 200 mA
... •Small DC current' s measurements: DC1 mA~200 mA •High accuracy: ±1 %FS±20 mV •Least influence of magnetization: Less than DC1 mA in current level •Convenient Single ...
... Connect directly to any XR440 or XR5-SE Data Logger. No external power is required. Also connects directly to any recorder or data acquisition system with a 0-5vdc input and 5vdc excitation. Single 5vdc supply, consumes less than 14ma 2kVRMS ...
Primary current: 50 A - 600 A
... Model : CHK_BR5S2 Nominal Current (RMS) :50/100/200/300/400/600A Vout/Iout @Ipn :2.500±2.0V Measuring Range :0~±600A Supply Voltage DC :+5V Accuracy (%) @Ipn +25°C :< ±1.0% Mounting (mm) :10.5*20.5 ...
Cheemi Technology Co., Ltd
Primary current: 25, 15, 6 A
... Technical indicators: Flame résistance: UL94-V0 Working température: -25—+70*C Storage température: -40—t-85'C Bandwidth: DC—150kHz Dielectric strength: 3KV 50Hz 1min ...
YHDC Dechang Electric
... Model 905B Bidirectional Current Transducer provides an isolated 0 to ±5Vdc output proportional to the DC input current, with a range from ±50mAdc to ±5Adc. The 905B Series delivers performance accuracy ...
American aerospace controls
Primary current: 25 A
... Hall Effect Current Sensor, Closed Loop These products are used in measurement of Alternating and Direct Current in electrical and electronic equipments such as SMPS, UPS, industrial ...
Electrohms
The Transducer, manufactured by ENTES, generally functions by converting electrical signals on their input into analog signals. In addition, this type of transducer is typically applied in control as well as in automation devices.
Primary current: 0 A - 32 A
... be seen as either a residual direct current monitoring device (RDC-MD) compliant to IEC 62955 or an AC/ DC RCM compliant to IEC 60947-2-(M) and IEC 62955 because the device has separate Pins for solely DC ...
Bituo Technik
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group