Distribution transformer SC
cast resindryfor electrical networks

Distribution transformer - SC - Ningbo Tianan (Group) CO.,Ltd. - cast resin / dry / for electrical networks
Distribution transformer - SC - Ningbo Tianan (Group) CO.,Ltd. - cast resin / dry / for electrical networks
Distribution transformer - SC - Ningbo Tianan (Group) CO.,Ltd. - cast resin / dry / for electrical networks - image - 2
Distribution transformer - SC - Ningbo Tianan (Group) CO.,Ltd. - cast resin / dry / for electrical networks - image - 3
Distribution transformer - SC - Ningbo Tianan (Group) CO.,Ltd. - cast resin / dry / for electrical networks - image - 4
Add to favorites
Compare this product

Characteristics

Type
distribution
Configuration
dry, cast resin
Applications
for industrial applications, for electrical networks
Electrical characteristics
three-phase, medium-voltage
Norms
IEC
Protection level
IP20
Other characteristics
compact, epoxy resin, with copper windings, short-circuit, oil-filled, dry type epoxy resin, air-insulated
Output power kVA

Max.: 2,500 kVA
(3,399.052888 hp)

Min.: 30 kVA
(40.788635 hp)

Primary voltage

10 kV

Secondary voltage

10 kV

Description

General
  • SC series 10 kV epoxy resin-cast dry-type transformer with vacuum-cast copper windings reinforced by glass-fibre; coils form a solid cylindrical epoxy body after curing providing high mechanical strength, strong short-circuit withstand and low partial discharge.
  • Insulation uses imported epoxy resin compounded with glass-fibre and silicon powder to improve thermal conductivity and flame performance; material does not emit toxic gases at high temperature.
  • Coils are moisture-resistant; core clamp coated with anti-corrosive material for reliable operation in severe conditions without routine dehumidification during intermittent use.
  • High short-circuit resistance and elevated lightning impulse withstand level.
  • Standard natural air cooling (AN); optional fan cooling (AF) to increase short-term overload capability. Thin external resin coating improves heat dissipation.
  • Low losses and low noise; compact, lightweight and oil-free design allows installation close to load centers without oil containment or special fire-fighting facilities.


Application
SC series dry-type transformers are intended as alternatives to oil-filled transformers and are suitable for high-rise buildings, commercial centres, theatres, hospitals, laboratories, museums, offshore platforms, ships, ports, stations, airports, petrochemical plants, underground railways, tunnels, mining sites, prefabricated substations and other critical public facilities.

Inquiry and order (information to provide)
  • Type / Model (specify)
  • Rated capacity: kVA (specify)
  • Number of phases / Frequency: Phase / Hz
  • Rated voltage: HV (kV) / LV (kV)
  • Tapping range: ±2x2.5%, ±5% or other
  • Connection symbol: D, yn11; Y, yn0 or others
  • Short-circuit impedance: % (specify)
  • Cooling method: AN or AF
  • Degree of protection: IP00, IP20 or IP23
  • Service conditions: altitude (m), ambient temperature (°C)
  • Optional accessories: temperature thermometer, temperature control box
  • Order quantities and delivery time


Energy efficiency / loss data (overview)
The product page provides detailed tables of no-load and load losses for 10 kV three-phase, double-winding dry-type transformers with on-load/no-load tap changers, covering rated capacities from 30 kVA up to 2500 kVA and IEC thermal classes B (100°C), F (120°C) and H (145°C). Recommended short-circuit impedance values are given per rating.

  • Examples (Rated capacity → No-load loss W / Load loss W for classes B/F/H, typical impedance):
  • 30 kVA → 105 W / 605 / 640 / 685 W (≈4.0%)
  • 100 kVA → 230 W / 1330 / 1415 / 1520 W (≈4.0%)
  • 500 kVA → 670 W / 4130 / 4390 / 4705 W (≈4.0%)
  • 1000 kVA → 1020 W / 6885 / 7315 / 7885 W (≈6.0%)
  • 2500 kVA → 2080 W / 14535 / 15445 / 16605 W (≈6.0%)


Technical specifications
  • Series / Model: SC series (10 kV product family)
  • Type: Epoxy resin-cast dry-type transformer (no oil)
  • Rated capacity range: typically 30–2500 kVA (specify required kVA)
  • Winding material: copper conductors for both HV and LV, glass-fibre reinforced, vacuum impregnated and cast
  • Insulation/casting: imported epoxy resin + glass-fibre composite with silicon powder additive
  • Thermal classes: B (100°C), F (120°C), H (145°C)
  • Cooling: AN (natural air) standard; AF (fan-forced) optional
  • Tapping range: ±2x2.5%, ±5% or customer specified
  • Connection symbols: D, yn11; Y, yn0 or others on request
  • Protection degrees available: IP00, IP20, IP23
  • Optional accessories: temperature thermometer, temperature control box

Catalogs

No catalogs are available for this product.

See all of Ningbo Tianan (Group) CO.,Ltd.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry