The P137 model is an application- and cost-optimized level transmitter, especially suitable as an OEM component. The screw cap simplifies handling and installation. It remains mounted during operation and protects the membrane from contaminants in the medium. The ceramic sensor operates according to the piezoresistive principle and in combination with the stainless steel housing forms a robust and slim probe. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this datasheet.
Features
Cost optimized for standard applications
22 mm Ø ideal for 1" pipes
Negative pressure measuring range: up to -1 bar
Accuracy ≤ 0,5%
Optionally integrated PT100 / PT1000 Sensor for temperature measurement
Applications:
Gaseous media
Technical data:
Power supply - 20 mA / 5 V output: 9…30 V DC
- 0,5...4,5 V output: 5 V DC
- 10 V output: 15...30 V DC
Accuracy - ≤ ± 0,5 % FS @ 25 °C
Long term stability - ≤ ± 0,5 % FS / Year
Response time - 50 ms - others on request
Switch-on time - < 1 s
Temperature coefficient - Zero: ≤ ± 0,03 % FS / Kelvin
- Span: ≤ ± 0,02 % FS / Kelvin
Medium temperature - -25…80 °C
Surrounding temperature - -25…80 °C
Storage temperature - -40…85 °C
Short-circuit resistance - Permanent
Reverse polarity protection - Protection against reverse polarity, but no function
Electromagnetic compatibility - Interference emissions and immunity acc. to EN 61326
Wetted materials -
- Messzelle: Ceramic Al2O3
- Screw cap: POM
- Sensor seal: FPM (Viton), EPDM, FFKM (Chemraz / Kalrez)
Weight - Approx. 450 g with 5 m cable