The membrane of the P142 level transmitter is welded directly to the housing and does not have to be sealed internally with an O-ring. The medium is only in contact with highly resistant CrNi stainless steel 1.4571 and there is no weak spot along an elastomer seal. The protective cap can be removed if necessary and the thread underneath can be used as a process connection. ATEX certified and with FEP suspension cable, the model is ideal for potentially critical areas and media. The measuring range can be adjusted on site using the HART interface. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this datasheet.
Features
Welded metallic measuring cell
Accuracy ≤ 0,25%
Analog output: 4…20 mA
Optionally integrated PT100 / PT1000 Sensor for temperature measurement
Ex II 1G Ex ia IIC T4 / T6 Ga
Applications:
Hygiene applications
Potentially explosive areas
Level monitoring in fuel tanks
Technical data:
Power supply - 20 mA output: 12…30 V DC
Accuracy - ≤ ± 0,25 % FS @ 25 °C
≤ ± 0,5 % FS @ 25 °C at pressure range ≤ 250 mbar
Long term stability - ≤ ± 0,2 % FS / Year
Response time - 200 ms - others on request
Switch-on time - < 1 s
Temperature coefficient - Zero: ≤ ± 0,02 % FS / Kelvin
≤ ± 0,04 % FS / Kelvin at pressure range ≤ 250 mbar
- Span: ≤ ± 0,02 % FS / Kelvin
Medium temperature - -20…100 °C
Storage temperature - -40…85 °C
Short-circuit resistance - Permanent
Reverse polarity protection - Protection against reverse polarity, but no function