SRV is installed in the place that require fast responding performance to protect the piping system from the surge(water hammer) by sudden flow change and pump sudden stop. Model SRV-PH consists of a main valve, solenoid valve, and N2 bottle, which is completely assembled and tested as a unit and ready for field installation. Main Valve is closed tightly when normal operation is in state. When a exceeding pressure in piping system is occurred, surge command from pressure transmitter operates the solenoid valve, and main valve is opened to protect the surge (water hammer). Full opening time is less than 100 millisecond.
Benefits
Adjustable of Opening and Closing Times
Opening and closing time of SRV depends on field condition, adjusted by solenoid valve with Nitrogen bottle.
In particular, full opening time is less than 100 millisecond.
Accurate and Precise Pressure Control
Pressure control of main valve is provided by accurate and precise pressure of Nitrogen supply.
Nitrogen System – Skid system(optional)
To reduce the effect of Nitrogen external temperature, SRV can also be supplied in form of Skid system(optional)