Climate chamber
thermostatichumidityhigh-pressure

Climate chamber - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / humidity / high-pressure
Climate chamber - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / humidity / high-pressure
Climate chamber - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / humidity / high-pressure - image - 2
Climate chamber - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / humidity / high-pressure - image - 3
Climate chamber - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / humidity / high-pressure - image - 4
Add to favorites
Compare this product

Characteristics

Type
climatic, thermostatic
Controlled parameter
humidity, high-pressure, temperature, pressure
Test type
HAST
Application domain
for the aeronautical industry
Configuration
floor-standing
Chamber material
stainless steel
Options and accessories
with temperature and climatic control
Other characteristics
accelerated, stainless steel
Capacity

Min.: 17 l
(4.49 gal)

Max.: 250 l
(66.04 gal)

Temperature

Min.: 100 °C
(212 °F)

Max.: 135 °C
(275 °F)

Interior length

Min.: 300 mm
(11.81 in)

Max.: 650 mm
(25.59 in)

Interior depth

Min.: 250 mm
(9.84 in)

Max.: 750 mm
(29.53 in)

External length

Min.: 850 mm
(33.5 in)

Max.: 1,300 mm
(51.2 in)

External height

Min.: 1,300 mm
(51.18 in)

Max.: 1,800 mm
(70.87 in)

External depth

Min.: 900 mm
(35.43 in)

Max.: 1,350 mm
(53.15 in)

Description

Overview
HAST (Highly Accelerated Stress Test) chambers create a controlled high-temperature, high-humidity and high-pressure steam environment to accelerate aging and reveal failure modes in electronic components, materials, coatings and sealants. The chamber shortens qualification cycles and supports reliability assessment and design validation.

Operation
Samples are placed inside the sealed HAST chamber and exposed to saturated steam under controlled temperature, humidity and pressure. The system provides forced steam circulation, precise temperature control and pressure monitoring to reproduce accelerated environmental stress. Tests detect material degradation, seal failures and process-related defects to inform corrective actions.

Application
  • Electronics: integrated circuits, printed circuit boards, semiconductor devices
  • Aerospace components and systems
  • Automotive electronic modules and sensors
  • Medical device components and assemblies

Specification
Internal dimensions Φ×D (mm): 300×250; 350×450; 450×550; 550×650; 650×750
External dimensions (mm): 850×1300×900; 900×1350×900; 1000×1480×1000; 1150×1650×1200; 1300×1800×1350
Steam temperature range: 100ºC ~ 135ºC (143ºC optional)
Relative/absolute pressure: gauge shows relative pressure; absolute pressure = displayed value + 100 kPa (actual inner-box value)
Steam humidity: adjustable 70–100% R.H. (saturated steam default)
Steam pressure (absolute): 101.3 kPa +0.0 Kg/cm2 ~ 2.0 Kg/cm2 (3.0 Kg/cm2 special option)
Recirculation: forced-circulation steam system
Safety devices: water short protection; over-pressure protection; automatic/manual water replenishing; automatic pressure discharge
Accessories: two-layer stainless steel inner plate
Equipment capacities (L): 17; 43; 87; 155; 250
Power supply: AC220V single-phase (1∮) 3 wires, 50/60Hz; AC380V three-phase (3∮) 5 wires, 50/60Hz

Performance
  • Temperature range: (RT+10ºC) ~ 135ºC, free setting (saturated steam temperature)
  • Humidity range: 100% RH (default saturated steam humidity)
  • Pressure range: 0.5 Kg/cm2 ~ 3.0 Kg/cm2 absolute (3.0 Kg/cm2 = 1 atm + 2 Kg/cm2)
  • Time range: 0 ~ 999 H/M/S; optional; configurable
  • Temperature uniformity: ±2.0ºC (at 100ºC)
  • Temperature rise time: (RT+10ºC) ~ 120ºC ≈ 45 minutes
  • Pressure rise time: ambient / 0.0 Kg/cm2 ~ 1.00 Kg/cm2 ≈ 45 minutes

Technical characteristics
  • Product type: High-pressure accelerated aging test chamber (HAST)
  • Available internal dimensions (Φ×D mm): 300×250; 350×450; 450×550; 550×650; 650×750
  • Available external dimensions (mm): 850×1300×900; 900×1350×900; 1000×1480×1000; 1150×1650×1200; 1300×1800×1350
  • Steam temperature range: 100ºC–135ºC (143ºC optional)
  • Steam humidity: adjustable 70–100% R.H.
  • Absolute steam pressure: 101.3 kPa +0.0 Kg/cm2 to 2.0 Kg/cm2 (3.0 Kg/cm2 special)
  • Forced-circulation steam system
  • Safety: water shortage protection, over-pressure protection, auto/manual water replenishing, automatic pressure discharge
  • Inner material/accessory: two-layer stainless steel plate
  • Capacities (L): 17, 43, 87, 155, 250
  • Power options: AC220V single-phase or AC380V three-phase, 50/60Hz
  • Temperature uniformity: ±2.0ºC (at 100ºC)
  • Approx. heating time to 120ºC: ~45 minutes

Catalogs

No catalogs are available for this product.

See all of AI SI LI (China) Test Equipment Co., Ltd‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.