The PICMA Tack Tester measures tacking strength between un-vulcanized rubber and un-vulcanized rubber or other materials.
Tacking strength of other adhesive materials can also be measured.
Measurement method - Load cell
Measuring load range - 0.0 to 30.0N
Sticking load - • 2 to 5N (Standard)
• Max. 20N (Optional)
Number of times to perform measurement - 1, 3, 5 (Selectable)
Sticking time - 0.0 to 99.9sec.
Specimen mounting wheel down speed - • 60mm/min.
• 1000mm/min.
Specimen mounting wheel separating speed - • 5, 10, 50, 100, 500, 1000, 1500, 3000mm/min. (Wide speed range)
• 5, 7.5, 10, 15, 20, 25, 30, 50mm/min. (Low speed range)
• 100, 500, 700, 1000, 1250, 1500, 2000, 3000mm/min. (High speed range)
Interface - RS-232C
Power supply - Single-phase, AC100 to 240V, 50/60Hz, 0.5kVA
Dimensions - W300 × D330 × H510 mm
Weight - Approx. 18kg