- Robotics - Automation - Industrial IT >
- Automation >
- Fieldbus I/O module >
- ADVANTECH
ADVANTECH Fieldbus I/O modules
1 Analog input channel measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal 1 Analog output channel voltage (±10 V) or current (0 - 20 mA), 100 kHz update rate High-accuracy ...
Gantner Instruments
... virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm Additional RS 485 fieldbus interface to control an 8 or 16 or 24 channel multiplexer for multi channel systems, ...
Gantner Instruments
2 Universal analog input channels Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 kHz sample rate per channel 2 ...
Gantner Instruments
... ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify I/O management with MXIO library for Windows or Linux platformsWide operating temperature ...
The ZC-16DI-8DO is an 16 CH input / 8 CH output mixed module. The inputs have 32-bit counters / 10 kHz max frequency, mosfet Outputs with shared negative pole. The communication protocols are CANopen or ModBUS RTU (protocol ...
SENECA | Automation Interfaces
ZE-4DI-2AI-2DO is an I/O module with 4 digital inputs, 2 analog inputs, and 2 digital relay outputs, for slave communication over ModbusTCP-IP (Ethernet) and Modbus RTU. The module has ...
SENECA | Automation Interfaces
R-16DI-8DO-P is a mixed digital module with dual 10/100 Mbps Ethernet ports. It is designed for flexible wiring needs, small installation space, high I/O density applications with built-in Ethernet networking. ...
SENECA | Automation Interfaces
Multi I/O is a device that integrates UPS into a control system using fully configurable input and output relay signals. It can be used to connect two devices to a single UPS serial communication port. It can be used ...
The Fieldbus technology is suitable with Schlegel control units particularly for operations utilizing a big number of control units and pilot lights to be connected to the fieldbus with little wiring. ...
... supports a wide range of end devices. • Analogue and digital I/O multiplexer • Data transfer via Modbus or exception reporting protocol • RS232 and RS485 communication ports • I/O interface for ...
... points are short-circuit proof and completely isolated from the CANbus. P317 modules may be mixed on the same bus, with other types in the Trio CAN I/O range. The Trio CANbus I/O expansion ...
Trio Motion Technology
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
> 16DO >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
... , and thermo-sensor modules. • Specifically designed for use with IMO i3 and XGB PLC • Analogue and digital I/O modules • Up to 16-bit resolution • Configurable inputs inc. DC Voltage, ...
... , and thermo-sensor modules. • Specifically designed for use with IMO i3 and XGB PLC • Analogue and digital I/O modules • Up to 16-bit resolution • Configurable inputs inc. DC Voltage, ...
GF 30 % Polyamid 8(12)~32 VDC -40°C … +80°C 35 + 23 Pin Tyco SealUSB2CAN interface for configuring device and diagnostics Up to 44 Digital Inputs Up to 4 Frequence Inputs Up to 44 Analog Inputs Up to 32 Current Inputs Up to 4 ...
Makersan
GF 30 % Polyamid 8(12)~32 VDC -40°C … +80°C 35 Pin Tyco Seal USB2CAN Interface for Configuring Device Up to 26 Digital Inputs Up to 8 Frequency Inputs Up to 26 Analog Inputs Up to 10 Current Inputs Up to 6 Resistive/Temperature ...
Makersan
Valve Controller GF 30 % Polyamid Silicon Rubber 8(12)~32 VDC 100mA typ. ( no load ) -40°C … +80°C 35 Pin Tyco Seal Connector User Configurable or Custom Software USB to CAN interface for device configuration Up to 24 Digital ...
Makersan
... programmable Rresistor module NXI-5100 supports LAN bus control. Its optional range of resistance is 0Ω~11.11MΩ. Resistance accuracy can be up to 0.1%. For different applications, the flexible design ...
... to 76,800 bit/s. The I/O modules are optimally designed for interaction with the BACnet router UBR-01 | Mk II. By using the router, the modules can then be connected to IT networks. Technical ...
... to 76,800 bit/s. The I/O modules are optimally designed for interaction with the BACnet router UBR-01 | Mk II. By using the router, the modules can then be connected to IT networks. Technical ...
... in the web interface and the numerous digital and analog I/Os. Two Ethernet Ports with a Daisy Chain function are available for the connection to the LAN network and the chain further Ethernet I/O devices. ...
METZ CONNECT
The I/O module in IP65 housing with 4 digital inputs and 2 relay outputs is developed for decentralized switching tasks. Suitable, for example, to accommodate light switches and window contacts in a room, ...
METZ CONNECT
The MB-DIO4/2-IP module in IP65 housing with 4 digital inputs, as well as 2 relay outputs, is suitable for the inclusion of decentralized signal contacts and the control of decentralized switching tasks. As signal contacts, ...
METZ CONNECT
... of IO-Link Ports - 4 IO-Link Port Class A - configurable conectors IO-Link Port Class B - configurable conectors Inputs/outputs - 4 x C/Q + 4 x I Sensor supply (IO-Link ...
Bihl+Wiedemann GmbH
... 50155 qualified input / output modules make it possible to build complete train control control (TCMS) architectures. These acquisition and control modules are based on a generic platform: the “Basic ...
LEROY AUTOMATION
The xtremeDB -1 (pronounced: "dash one") CANopen module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog mode. Two ...
... the same time, the module offers 14 digital outputs, most of which can be configured as PWM or PWM(i). The maximum output current of 7 A is sufficient to control even actuators with high power. Fully potted IP69K CANopen ...
Our comment on "xtremeDB 8 inputs 8 outputs, SAE J1939" The xtremeDB -1 (pronounced: "dash one") SAE J1939 module combines many different I/O signal configurations. It offers a total of eight inputs, ...
... As an IIoT I/O module, ATOP’s IO5202 Series is a compact solution for connecting digital and analog devices and sensors, enabling you to monitor, acquire and process data from remote ...
Multifunction I/O, Digital Source I/Os for nominal 24 volt, Analogue I/Os for 4-20 mA signals, P-NET via Light-Link, Programmable in COPP • Digital Source I/Os for ...
PROCES-DATA A/S
... operated in the temperature range between -20 and +55 °C. The I/O Modules of Mx110 series offer a cost-effective and flexible solution in distributed automation systems. The robust modules ...
Long-Range, Scalable and Highly Resilient Multi I/O Node and Gateway The ELPRO 915U-2 Wireless Mesh Networking I/O and Gateway is a multiple I/O node that extends communications to ...
ELPRO Technologies
The RIO40S remote I/O module, based on a CANopen architecture, ensures fast and reliable communication. Ultra compact, it can be easily integrated into any type of cabinet or electrical cabinet. Thanks ...
SERAD
... acquisition modules, which are also called distributed IO modules, IO modules, data acquisition cards, data loggers, and IO cards. FEATURES ...
BRAINCHILD ELECTRONIC CO., LTD
... and fieldbus connections. You can choose and combine your needed type of connection: Central, using local I/O bus of CPU module. Up to ten I/O ...
ABB Automation Products GmbH
8 Digital Inputs, 8 Digital Outputs and an RS485 Gateway Port Control any input or output from TTL to high voltage high current industrial devices Factory floor process control and automation, Integrated DIN rail mount Supports simple ...
Brainboxes
The DAT 3011 device is specially designed to acquire RTD or Tc sensors, mV, V or mA input signals connected to the universal analog input. It is also capable acquire up to 3 digital inputs and to drive one solid-state relay and two SPST ...
DATEXEL SRL
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining