Kübler DIN rail monitoring relays
The ENTES Current Monitoring Relays are specially designed to offer protection to the motors and networks against under and over current conditions. The relays are available in four series ...
ENTES
Trigger voltage: 85 V - 480 V
... circuit, driving an electromechanical relay with one SPDT and one SPST contact. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize ...
*Delicate Design: - MCU control with SSR control contact * Optimum Flexibility - Wide Current Adjusting range (100%~1200%) - External CT available (100:5 / 150:5 / 200:5 / ...
Phase monitoring relays Eaton’s D65 phase monitoring relays protect loads from voltage fault conditions. The devices provide protection against phase loss, phase reversal, ...
Eaton Count Control Products
Trigger voltage: 24 V - 240 V
... safety relays offer outstanding simplicity, flexibility and cost-effectiveness. Their modular design simplifies the planning, commissioning and expansion of plants. Simple safety functions, such as EMERGENCY STOP and ...
Siemens Safety Integrated
Are you responsible for signal technology or safeguarded level crossings in the rail industry – or are you looking for the optimal process safety solution for your pipeline, turbine, or deep-sea application? The highest ...
• Undervoltage, overvoltage and frequency monitoring of AC/DC systems 0…300 V • Various monitoring functions selectable U, f • Adjustable start-up delay, response delay and delay on release • Password ...
BENDER
Tripping current: 1, 4, 24 A
Trigger voltage: 24, 120, 30 V
... component failure DIN Rail or panel mount LED power on indicator The INT-04-024 or INT-04-120 Safety Relay is intended for use as a part of a safety circuit in emergency-stop of safety ...
EDWARDS SIGNALING
Power relay, single-phase network 2 Module Non-priority load tripping management Relay output for load tripping or external sound signaling (selectable) Inner alarm Buzzer Measuring range: 0...6.5 ...
Trigger voltage: 110 V - 240 V
TE-RTD12 Motor RTD Monitor / Relay Device The TE-RTD12 Relay device adds advanced RTD (Resistor Temperature Detector) and differential current monitoring capability to your new or ...
... marine-approved. It ensures over speed and mandatory channels, such as low lube oil pressure and, high coolant temperature monitoring in order to shut down engine to prevent any damage.
Motor Management Relay The SEL-849 Relay offers current-, voltage-, and thermal-based motor protection; arc-flash detection; and power metering. It also provides all basic motor protection features, ...
Trigger voltage: 24 V - 240 V
... Current monitoring relay PRI-51 features its ability by controlling the heating of rods in shunts, of cables, to direct current flowing, to monitor utilization of single-phase electrical loads. This product ...
ETI
... The range includes relays suitable for installations with DIN rail, Panel or Base Mounting. All relays are suitable for use on a.c. systems and will be unaffected by ...
Tripping current: 0.02 A - 2 A
... Under or Over current monitoring (selectable) - 3 Selectable current ranges (0.2A, 1A or 2A) - Adjustable Trip level, Hysteresis and Time delay + Latch - Isolated Auxiliary supply - SPDT Relay output - ...
Broyce Control
Trigger voltage: 24 V
The muting function enables personal protection without impeding the material flow Safeguarding access to automatic production plants Safeguarding drive-in openings to production cells Safeguarding palletizing plants Conveying and storage technology
Fiessler Elektronik
Tripping current: 10 mA
Trigger voltage: 30, 250 V
... The module is based on the use of safety relays with guided contacts and can be configured both with automatic reset and manual reset. Furthermore, it has an auxiliary signaling output with relay, ...
WIDE Automation
... with LED indication of input status. Redundancy and cycle monitoring. Feedback loop for monitoring contacts or expansion modules. Short circuit and earth fault monitoring. 22mm ...
Idem Safety Switches
Features •SIL 3 according to DIN EN 61508 and DIN EN 61511 •SIL CL 3 according to EN 62061 •Performance Level e according to DIN EN ISO 13849-1 •Safety category 4 according to ...
Tripping current: 5 A
Voltage monitoring in 3-phase mains Meassuring circuit data Functions OVER, OVER+LATCH, UNDER, UNDER+LATCH, WIN, WIN+LATCH timing adjustment for tripping delay Time intervals (timing adjustment) tripping ...
RELPOL
... as "simple apparatus", system certification is not needed. The slimline units are universal DIN-rail mounting and can be supplied pre-mounted in standard safe-area or flameproof enclosures as required.
... output relays, are self-monitoring, and are rated Control Reliable, which means that any fault in the safety-critical components will be detected and the machine will be rendered inoperative until the ...
Tapeswitch
Tripping current: 16 A
... AC 400 V. Output contact: 2x changeover/DPDT 16 A /250 V AC1. Sensitivity adjustable by potentiometer. 3-MODULE, DIN rail mounting.
ELKO
Trigger voltage: 24 V - 230 V
Stop category: 0 Performance-Level: e Safety category: 3(4) 1 or 2 channel emergency stop circuit Contacts: 2 force guided safety contacts AC 250V/6A Operating voltage: DC24V, AC230V, AC115V Dimension: 22.5mm
Zander GmbH & Co. KG, Hermann
Trigger voltage: 100 V - 415 V
... network. The trip level is factory set and relay will operate after a delay of approximately two seconds. Relay is fail-safe and energises when powered. Link terminal 6 and 10 to make a non-latching ...
Meagacon AS
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining