LEUZE monitoring relays
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Trigger voltage: 24 V
The Safety Control Module SBR031LC has three safety contacts, and one signal output. This product is great for processing potential-free outputs, emergency stop command devices, position switches or solenoid interlocks.
SCHMERSAL
Trigger voltage: 24 V
Best with regard to signal assessment involving results of security magnetic fuses Drop-out hold off could be established around 0,4 until 1,5 s 3 security connections, STOP 1 1 Signalling yield Well suited for signal handling ...
SCHMERSAL
Trigger voltage: 24 V
... is a two-function safety monitoring unit that uses a double evaluation setup and two enabling paths with their own shut-down setups. It uses an emergency exit opening to get both paths up. It also has a guard door ...
SCHMERSAL
Tripping current: 30, 6, 10 A
Trigger voltage: 220 V - 415 V
... multifunction devices that allow monitoring of undervoltage and overvoltage, phase sequence and phase failure. Features include (according to Type): • Multifunctional types, providing the flexibility of monitoring ...
Tripping current: 8 A
These safety magnetic controllers have been certified to be compliant with the performance level D of the EN ISO 14849-1 standards, which makes them suitable for various applications for which safety is the main requirement. The safety ...
Tripping current: 5 A
From safety relays to safety switches, the complete range of products needed for your application can be found at Bernstein. The SCR safety relays reliably evaluate signals including those created ...
Tripping current: 500, 200 mA
Trigger voltage: 24 V
Self-monitoring, short-circuit proof inputs and outputs E-STOP with cross-fault monitoring and optional simultaneity monitoring Connection of mechanical safety switches and ...
ifm electronic
Tripping current: 208 mA
Trigger voltage: 24 V
For the connection of safety light curtains / safety light grids with OSSD Safety relay with integrated muting function Safety category type 4 to IEC 61496 Integrated signal and feedback contacts
ifm electronic
Tripping current: 200 mA
Trigger voltage: 24 V
... pulse comparison of two sensors Redundant structure of the hardware Redundant evaluation of the pulse sequences Relay with positively-driven contacts Four switch points selectable
ifm electronic
... module models have a variety of safety inputs, solid-state safety outputs and safety relay outputs • Innovative live display feature and diagnostics allow for active monitoring of I/O on a PC and assist ...
BANNER ENGINEERING CORP.
Trigger voltage: 24 V
... applications, such as photoelectric monitoring position or end-of-travelThe safety inputs can monitor:+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup+24V dc source that is switched by hard/relay ...
BANNER ENGINEERING CORP.
Trigger voltage: 12 V - 230 V
... amps, depending on module Non-safety auxiliary outputs are available on most modules Two modules allow central monitoring and control over a DeviceNet control network Ratings are NEMA 1 and at least IEC ...
BANNER ENGINEERING CORP.
... a fast linear trip is required. All of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and ...
Littelfuse
... combines the features of a ground-fault protection relay and insulation monitor into one unit. It protects against ground faults by monitoring insulation resistance when the motor is ...
Littelfuse
Trigger voltage: 65 V - 265 V
... neutral-grounding resistor monitoring relay that is compliant with Rule 10-302 of the 2018 Canadian Electrical Code Part I (CE Code). It measures neutral current, neutral-to-ground voltage, and neutral-to-ground ...
Littelfuse
... as simple. When user needs change, it can be adapted quickly and easily to meet those needs. Unlike hard-wired safety relays, the Omron G9SP can be reconfigured to multiple purposes. Because it is a solid-state, ...
Tripping current: 5 A
Trigger voltage: 250, 30 V
Proven and popular safety relay units Output expansion, DC power supply, and AC power supply models • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay ...
Tripping current: 0 mA - 20 mA
Trigger voltage: 2 V - 10 V
The Monitoring Relay MR50Ex has inputs for industry standard signals 0/4..20 mA and 0/2..10 V DC. Measuring value and the programmed unit are shown in the display. The integrated transmitter supply offers ...
Trigger voltage: 110, 230, 400 V
... of the speed of the generator with built-in pulse output Protection with password. CIRCUTOR has two types of synchronism relays: SYNCHRO MAX and SYNCHRO MAX PID. Synchro Max Synchro Max is capable of adapting ...
Tripping current: 0.03 A - 5 A
Electronic industrial earth leakage protection relay, compatible with the WGC series protection transformers. Type A ultraimmunised relay with high frequency current filtering and high immunity. True ...
Electronic earth leakage current intensity monitoring relay (IEC 62020), compatible with the WGC-TB series protection transformers. The RGU-10B is the most complete system of the range that monitors and ...
... According to EN 50156-1 for furnaces • 2-channel operation • Forcibly guided output contacts • With or without cross fault monitoring in the E-stop loop, switch S1 • Manual restart or automatic restart, switch S2 • ...
DOLD
The multifunctional safety module UG 6970 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. Up to two independent safety functions which are selected in a simple way ...
DOLD
The multifunctional safety timer UG 6960 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. The UG 6960 combines safety time functions and safety functions ...
DOLD
Trigger voltage: 24 V - 230 V
Modular isolation monitoring devices Sentinel Isolation monitoring sentinel for LV networks up to 500 Vac; 2 modules; 110–230–400 Vac power supply.
... independent, non-certified incremental encoders, signal splitter, wire monitoring DS260: Input for one certified incremental encoder, signal splitter, wire monitoring The DS series is ...
... output relays and 1 analog output DZ261: 3 transistor outputs and 1 analog output DZ266: 1 analog output DZ267: 3 output relays DZ269: 3 transistor outputs Fast response speed monitoring ...
Trigger voltage: 24 V
... , 8/4 safe shutdown channels, 1 safe 1-channel potential-free relay contact. Contact multiplication or contact amplification by external contactors in connection with integrated monitoring possible (EDM). The ...
Trigger voltage: 24 V
... , 8/4 safe shutdown channels, 1 safe 1-channel potential-free relay contact. Contact multiplication or contact amplification by external contactors in connection with integrated monitoring possible (EDM). The ...
The T-154 Temperature Relay with Digital Display is a microprocessor-based electronic device for temperature monitoring and control of dry-type encapsulated transformers. The T-154 temperature relay ...
Tripping current: 20 mA
Trigger voltage: 24 V
... tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary • Earth fault/ground fault ...
Tripping current: 0 A - 0.4 A
Trigger voltage: 24 V
... restarting semiconductor outputs or for external device monitoring (EDM) • 2 dual-channel outputs (PL e, category 4) • 4 test outputs for monitoring for short circuits and overload states • 2 monitoring ...
The U1, the U1D, and the U1M, which are manufactured by Fanox, are single phase voltage relays that are DIN mounted. The U1 features two potentiometers, and the minimum and maximum thresholds can be modified. The U1D ...
Trigger voltage: 24 V
Controllers monitor the safety field of several through-beam sensors. Interruption of the light beams results in the safety output being switched off. The individual light barrier controllers offer various operating modes, the extended ...
Trigger voltage: 22 V - 29 V
... combination with the safety light curtains SG-I and safety light arrays SB-I, the relay unit allows for the interruption of safety-relevant circuits. Floating safety relays are utilized.
Trigger voltage: 24, 230 V
This is a voltage monitoring relay module that is capable of measuring 1-phase networks. Our E1UM230V01 lets you select a suitable voltage range of 24V AC, 24V DC or 230V AC in one device. The settings ...
TELE Haase Steuergeraete GmbH
Trigger voltage: 690 V
... feedback of the power and phase condition while two integrated relay outputs (DPDT configuration) trigger alarms to your PLC or trigger actions. Our TELE technology allows to power our monitoring relay ...
TELE Haase Steuergeraete GmbH
Tripping current: 10 A
... is an AC current monitoring in 1-phase which is equipped with thresholds and hysteresis. The multifunction device also has tripping delay that helps in monitoring relays. It has various ...
TELE Haase Steuergeraete GmbH
Trigger voltage: 24 V
MZERO - A compact and configurable safety controller MZERO is a configurable safety hub able to manage all safety functions of a machinery or a plant. Configurable, allows cost reductions and minimal wiring. MZERO can manage ...
REER
Tripping current: 100 A
Trigger voltage: 24 V
... safety outputs, and the machine control circuits. * Guided-contact safety relays * Start/Restart interlock * EDM Feedback input for extra external contactors monitoring
REER
Tripping current: 6 A
... stop buttons and safety switches Safety relay for emergency stop buttons and safety switches monitoring. Guided-contact safety relays 2 N.A. + 1 N.C. EDM Feedback input for external ...
REER
Tripping current: 4, 6 A
Trigger voltage: 250, 240, 24 V
Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel three modes are optional. Independent channel status signal output, ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 250, 240, 24 V
Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel three modes are optional. Independent channel status signal output, ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 250, 240, 24 V
Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel three modes are optional. Independent channel status signal output, ...
Bytorent Technology Co., Ltd.
Tripping current: 5 A
Trigger voltage: 30, 230 V
The BMRCD-01 modular residual current device can be installed with MCCB and MCB in addition to shunt/under-voltage release for residual current protection. BMRCD-01 consists of a controlling module and detecting modules (only B-type detecting ...
... for monitoring an individual phase. All unoccupied inputs have to be connected to the connected phase. If there is an inverse voltage due to the consumer, which exceeds the adjusted threshold value, there is not any fault ...
METZ CONNECT
Trigger voltage: 400 V
... or 21, 24 of the relay output contacts are connected ahead of the field coil of the motor relay. If the phase sequence is correct, the output relay is activated (green LED is on). In ...
METZ CONNECT
Monitoring relay for monitoring asymmetry, phase failure, phase sequence errors, overvoltage and undervoltage of a three-phase connection. With external fault acknowledgement. •Connection ...
METZ CONNECT
Tripping current: 8 A
Trigger voltage: 250 V
Sensor controller on Acotom process / mechanical switches / emergency stops Output contacts 8A/250V Anti-gluing control of the reset button Ultra-fast "DLC" short-circuit check : Short-circuit detection in 2 µs, self-resetting Safety ...
COMITRONIC - BTI
Tripping current: 8 A
Trigger voltage: 250 V
Sensor controller on Acotom process / mechanical switches / emergency stops Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with ...
COMITRONIC - BTI
Tripping current: 8 A
Trigger voltage: 250 V
Sensor controller on Acotom process / mechanical switches / emergency stops Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level ...
COMITRONIC - BTI
Trigger voltage: 24, 42, 115, 230 V
The Klaschka Pulse Rate Measuring Relays can be applied as a standstill monitor of turning equipment, in a wide range of applications that involve machines and plants, vehicles and ships, mining industry, process engineering, ...
KLASCHKA Industrieelektronik
Trigger voltage: 24, 42, 115, 230 V
FSN Frequency and pulse rate measuring relays complete the ISN pulse rate measuring relay with high frequencies. Three threshold ranges from 100 Hz to| 120 kHz can be selected.
KLASCHKA Industrieelektronik
Tripping current: 1 mA - 15,000 mA
The undervoltage and overvoltage protection relay, manufactured by Klaschka, is a robust version relay that is incorporated with a self-supervision system and restriction settings. This is built to control ...
KLASCHKA Industrieelektronik
Trigger voltage: 20 V - 240 V
... function Local Reset function Local Remote Output relays 2 changeovers (TRIP+SAFE, ALARM) 5 A (240 VAC) 0,3 A (110 VDC) 2 A (48 VDC) Display indications LED green(power ON) LED red TRIP (Relay ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining