- Electricity - Electronics >
- Switch and Relay >
- IP67 switch >
- Lumibird
Lumibird IP67 switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 4 A
Voltage: 10 V - 30 V
... In-line capacitive touch switch with M12 connectors Easy installation with clip-in brackets and durable M12 in-line connection Customizable intensity control and capability to dim lights using PWM output Bright indication mimics light ...
... programmable using Banner’s Pro Editor Software and Pro Converter Cable for customization of colors and animation - Rugged IP 67 and IP69K construction for high-pressure washdown environments - Advanced ...
... optional high-extraction-force actuator. Design meets positive opening requirements for safety interlocks. IEC IP65 switch housing rating increases to IEC IP67 with addition ...
Primary current: 20.4 A - 26.4 A
Voltage: 24 V
... possible • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Open-circuit current principle • Category 4 / PL e according to EN ...
EUCHNER GmbH + Co. KG
Primary current: 20 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... suitable actuator is detected by the switch. Guard locking operated by means of input signal. This type of guard locking has a function to prevent persons from unintentionally locking themselves inside if the safety ...
EUCHNER GmbH + Co. KG
Primary current: 20 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... suitable actuator is detected by the switch. Guard locking operated by means of input signal. This type of guard locking has a function to prevent persons from unintentionally locking themselves inside if the safety ...
EUCHNER GmbH + Co. KG
Primary current: 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... power. AS-Interface inputs D0, D1 Door monitoring D2, D3 Guard lock monitoring Evaluation is performed via a safety monitor. AS-Interface outputs D0 Guard locking D1 LED red D2 LED green LED function ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 0 V - 1 V
Operating temperature: -20 °C - 55 °C
... • Guard locking suitable for process protection only • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 • With plug connector M12 • Unicode • With escape release • ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 100 mA
Voltage: 5 V - 24 V
Operating temperature: -20 °C - 55 °C
... • Up to 20 switches in series • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 • With 2 plug connectors M12 • Multicode • Door monitoring ...
EUCHNER GmbH + Co. KG
Primary current: 50, 40 mA
Voltage: 26.5 V - 31.6 V
Operating temperature: -20 °C - 55 °C
... monitoring Evaluation is performed via a safety monitor. AS-Interface outputs D0 Guard locking LED function display The ASI LED indicates the state of the ASi bus. The STATE LED indicates the state of the switch. The ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 150 mA
Voltage: 0 V - 1 V
Operating temperature: -20 °C - 55 °C
... • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Closed-circuit current principle • Up to category 4 / PL e according to EN ISO ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... • Up to 20 switches in series • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Closed-circuit current principle • ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... • Locking force up to 6,500 N • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Category 4 / PL e according to EN ISO 13849-1 • With 1 plug connector M12, 8-pin • Unicode • Door monitoring output • Indication ...
EUCHNER GmbH + Co. KG
Primary current: 10 mA
Voltage: 12 V
Operating temperature: -40 °C - 85 °C
... SWA is a miniature snap-action switch, also known as a micro switch whcih is designed for the requirement of waterproof IP67, anti-vibration as an automotive sensor or electric switch ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group