Mass flow analog output flow meters

Process temperature: -20 °C - 800 °C
... the evaluation unit, the AirFlow P system supplies a signal at the analogue output cubic metres per hour (v x A). By using the latest technologies, it is possible to measure a volume flow ...

Process temperature: 150 °C
Process pressure: 150 bar
... reagent in flue gas treatment and transport lines with very low material concentration Electrodynamic flow sensor for measurement of low flow rates from 0 to 100 kg/h. For pipe diameters up to 1 ...

Process temperature: 0 °C - 120 °C
Process pressure: 10 bar
... or ducts • No real upper limit of mass flow • Maximum pressure 10 bar • Dust tight • No flow restrictions to the process flow (wear resistant ceramic liner) • The mass flow ...

Volumetric flow rate: 0.9 l/min - 240 l/min
Process temperature: -40 °C - 125 °C
Process pressure: 0 bar - 18 bar
... difference between flow sensor type 236 and type 210 is the version of the case. The Vortex sensor type 236 has a rugged construction of brass connection. This flow sensor is available with a larger variety ...

Volumetric flow rate: 0.8 l/min - 630 l/min
Process temperature: 0 °C - 90 °C
Process pressure: 0 bar - 16 bar
... treatment or food production: If non-conductive media flow in a chemical process, ultrasonic flow meters are usually installed for monitoring. For monitoring, the measuring devices require ...
KOBOLD Messring GmbH

Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: -25 °C - 180 °C
Process pressure: 40 bar
Electromagnetic induction flow meter Suitable for conductive fluids Size from DN 10. to DN 2200 Flanged / Threaded UNI-ISO-ANSI Electrodes in SS316L-Hastelloy C-Titanium-Monel-Tantalio-Tungsten Internal ...
ASIT ITALIA

Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: -25 °C - 180 °C
Process pressure: 40 bar
... aluminum / carbon steel / SS304 Separate electronic version Power supply 100-240VAC / 20-36 Vdc / Battery Available outputs: Analogue / pulse / Frequency / Profibus / HART / GPRS / MODBUS
ASIT ITALIA

Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: 40 °C - 180 °C
Process pressure: 40 bar
The AI.MF4000C series electromagnetic flow meters can be used to accurately measure the flow rate of any type of conductive liquid which are electrical conductors, caustic and mixed with liquids ...
ASIT ITALIA

Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one ...
VPInstruments

Volumetric flow rate: 0 m³/h - 1,000 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 Pa - 3,500,000 Pa
... consumption of machines, cost allocation, and pressure loss monitoring. It measures (bi-directional) mass flow, temperature, pressure, and total flow which is key data for point of use ...
VPInstruments

Volumetric flow rate: 2.2 l/min - 50 l/min
Process temperature: 20 °C - 32 °C
Process pressure: 0 bar - 10 bar
... Thermabridge™ technology, the VPFlowScope In-line can perform accurate flow measurements. The built-in display will show the actual and total flow, and the Modbus and analog 4 .. 20 mA ...
VPInstruments

Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
... angle measurement - Optional (RQ-30a): analogue outputs from 4 to 20 mA FIELDS OF APPLICATION The RQ-30 enables discharge measuerment for rivers, streams, open channels and canals for which ...
SOMMER Messtechnik GmbH

Process temperature: -35 °C - 60 °C
Precision: 1 %
Repeatibility: 0.1 %
... non-contact measuring, maintenance free and flood-proof - No structural work is necessary in the water - Recognition of flow direction and hysteresis effects - Measurement in tidal waters - Measurement ...
SOMMER Messtechnik GmbH

Process temperature: -40 °C - 85 °C
Precision: 1 %
... , it is the ideal choice for flow measurements in manholes of facilities and sewers. FEATURES AND ADVANTAGES Non-contact measurement, maintenance-free system Calculation of discharge by continuous ...
SOMMER Messtechnik GmbH

... industrial application. Air flow measurement up to 120 m/s. Resistant to high temperature, high pressure, dust, and corrosion. Sensor type : Pt20 / Pt300(Air velocity) / Pt1000(Temp.) Measuring range : 0 ... 120 Nm/s Output ...

... Suitable for clean air. Resistant to high pressure and high temperature. Sensor type : Thermal mass flow sensor Measuring range : 0 ... 90 m/s Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... ...

Sensor type : Thermal mass flow sensor Measuring range : 0.1 ... 848 m³/h Output : 4 ... 20 mA / 0 ... 10 V / RS-485 / Frequency / Pulse Accuracy : ±1.5% F.S. IP rating : IP65 (IP67 option)

Volumetric flow rate: 0.1 m³/h - 9.5 m³/h
Process temperature: -20 °C - 130 °C
Process pressure: 0 bar - 64 bar
The RIF100 is an electromagnetic flow meter that utilizes Faraday's principle to measure the velocity of the liquid and convert it into a signal proportional to the flow. Among its ...
Riels Instruments

Volumetric flow rate: 0.2 l/min - 100 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 16 bar
... SIGNAL INPUTS AND OUTPUTS Signal Output Type - Digital and Analog Analog output functions - Volumetric flow Frequency ...
Riels Instruments

Process temperature: -25 °C - 80 °C
Process pressure: 0 bar - 64 bar
... electromagnetic flow meter insertion designed to measure the flow of conductive liquids in pipes. The device can be inserted directly into the pipe without the need for invasive operations, ...
Riels Instruments

... the sensor settings like pipe diameter, gas type or analog output scaling. The sensor offers two different signal output options. It can have a isolated analog and pulse ...
SUTO iTEC GmbH

Process temperature: -30 °C - 70 °C
Process pressure: 0 bar - 10 bar
Precision: 1.5 %
... Thermal mass flow with no additonal compensation required Perfect to measure your compressed air flow and consumption Economic and affordable compressed air flow meter ...
SUTO iTEC GmbH

Process temperature: -40 °C - 120 °C
Process pressure: 0 MPa - 5 MPa
Repeatibility: 0.25 %
The S453 Compressed Air Flow Meter is specifically designed for heavy-duty and explosive (Ex) environments, providing precise and reliable thermal mass flow measurements for your industrial ...
SUTO iTEC GmbH

Process temperature: -10 °C - 100 °C
Process pressure: 0.2 MPa
Precision: 2.5 %
... probe with integration of temperature and humidity sensors. The air flow is calibrated in a wind-tunnel. The products are designed for acquiring the environmental data of air mass velocity, temperature ...

Volumetric flow rate: 0 l/min - 800 l/min
Process temperature: -10 °C - 55 °C
Process pressure: 1 MPa
... series mass flow meters are designed for general purpose flow metering and control applications and are made with Siargo's proprietary MEMS mass flow sensing technology ...

Volumetric flow rate: 21 l/min - 200 l/min
Process temperature: 0 °C - 100 °C
... triggered by this micro-switch. Furthermore, a display system is activated that shows the current flow quantity on the scale. Display of the current flow simple adjustment of the switching ...

Precision: 0.2 %
... ADVANTAGES OF ELECTROMAGNETIC FLOWMETERS OVER OTHER FLOWMETERS · There are no mechanical parts that prevent the flow and reduce the pressure. · Measurement scale; It is ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.

... precise flow measurements can be made without the need for costly modifications on the existing line. There are no mechanical parts that prevent the flow or reduce the pressure. measurement scale; It ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.

Mass flow rate: 2.2 kg/h - 243,954.2 kg/h
Volumetric flow rate: 1.2 m³/h - 30,000 m³/h
Process temperature: -40 °C - 450 °C
... can be used in many different fluids. Immersion Vortex flowmeters are a preferred model in areas where serial flowmeters cannot be used, or in environments with high pipe diameters. Although the working ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.

Volumetric flow rate: 0.3 l/min - 140 l/min
Process temperature: -20 °C - 70 °C
SONOFLOW CO.55 CLAMP-ON SENSOR - NON-CONTACT FLOW METERS FOR LIQUIDS IN FLEXIBLE TUBES The ultrasonic clamp-on flow meter SONOFLOW CO.55 measures the flow ...

Volumetric flow rate: 14 l/min
Process temperature: 10 °C - 50 °C
The hybrid flow-bubble sensors of the series SONOFLOW CO.56 Pro V2.0 and SONOFLOW CO.56 combine accurate flow measurement and reliable air bubble detection in liquid filled medical tubing. They feature ...

Process temperature: -20 °C - 70 °C
Process pressure: 0 bar - 16 bar
The SONOFLOW IL.52 ultrasonic flow sensor uses bidirectional measurement in order to achieve excellent precision, detecting even the smallest flow rates with speed and efficiency. It's construction and ...

Volumetric flow rate: 0.63 ft³/min - 120 ft³/min
... CentriFlow Meter from Eastern Instruments is a Solid Particle Mass Flow Meter that is durable, accurate, maintenance-free, compact, and cost-effective. It is unique and positioned to ...
Eastern Instruments

Mass flow rate: 2 lb/h - 200 lb/h
Volumetric flow rate: 1.69 ft³/min - 90 ft³/min
... measuring less expensive products, flow meter cost can be a determining factor in the selection of a flow meter. Unfortunately, extremely accurate flow ...
Eastern Instruments

Mass flow rate: 100 lb/h - 1,000,000 lb/h
Volumetric flow rate: 0.1 ft³/min - 156.3 ft³/min
Repeatibility: 0.1 %
... depending on your process. The CentriFlow® Type I Meter, just as all CentriFlow® brand meters, is a mass flow meter designed for measuring bulk solids continuously ...
Eastern Instruments

Volumetric flow rate: 0 l/min - 525 l/min
Process temperature: -40 °C - 210 °C
Process pressure: max 450.0 bar
VSI+ flowmeters measure the volume flow of the medium according to the gearwheel principle. A gearwheel pair fitted very precisely in the housing forms the measuring unit. The rotation of the measuring ...
VSE Volumentechnik GmbH

Volumetric flow rate: 0 l/min - 3,000 l/min
Process temperature: -40 °C - 210 °C
Process pressure: 0 bar - 450 bar
... viscosity oil or viscous resin - RS flow meters are the ideal solution for precise flow measurement. Thanks to various bearings, tolerances, materials, coatings, electronics and resolutions, ...
VSE Volumentechnik GmbH

Volumetric flow rate: 0.1 l/min - 150 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 200 bar
... we have launched the VSE EF ecoflow series onto the market. The VSE EF ecoflow aluminium flow meter uses the same gearwheel pairs as in the VS. The flow meters work ...
VSE Volumentechnik GmbH

Volumetric flow rate: 30 l/h - 1,200 l/h
Process temperature: -20 °C - 90 °C
Process pressure: 0 bar - 12 bar
... ranges except the standard 0.520 l/min flow range are available on request. PSF20x is equipped with a keyboard and a local 3-digit LED display for easy programming and flow monitoring and can be used ...

Process temperature: -10 °C - 50 °C
... , thermal, Pt100 and any other physical sensor with analog output) thus allowing for a wide range of applications. Measuring applications with the flowtherm Ex are manifold: gas mass flow ...

Process temperature: -40 °C - 150 °C
Process pressure: 5 bar - 200 bar
... or gasoline engines. FAST: This instantaneous mass flowmeter allows you to measure up to 10 injections per revolution. COMPACT: Only one device is necessary to measure the quantity injected and ...

Process temperature: -20 °C - 150 °C
Process pressure: 10 bar - 200 bar
Precision: 0.1 %
The IFR 6000-40000 (Injection Flow and Rate) flowmeter is dedicated to instantaneous flow measurement of large and very large injection volumes and injection rate. It makes possible controlling ...

Process pressure: 10 bar - 100 bar
The IFR 600 (Injection Flow and Rate) flowmeter is a device intended to measure injection volumes or masses but also the injection law step by step. It is used to control the high energy systems fitted ...

Mass flow rate: 1 kg/h - 20,000 kg/h
Process temperature: -20 °C - 450 °C
Process pressure: 0 bar - 6 bar
Microwave-based flow measurement for bulk solids MF 3000 Numerous bulk material applications require continuous measurement of mass flow, e.g. for exact dosing of ...

Volumetric flow rate: 0.3 m³/h - 71 m³/h
Process temperature: -15 °C - 100 °C
Process pressure: 0 bar - 10 bar
... Treatment. 2.FineTek EPD/EPR series Flow Meter with high quality 3.EPR series Paddle Wheel Flow Meter 4.FineTek EPR Paddle Wheel Flowmeter 5.Total ...

Volumetric flow rate: 0.2 l/min - 1,000 l/min
Process temperature: -50 °C - 300 °C
Process pressure: 10, 40, 16 bar
Flowmeter for liquids and gases high accuracy product specific scale several options Operation: The instruments, type SC-250H and SC-250V, are variable area flowmeters.

Volumetric flow rate: 0.5 m³/h - 3,000 m³/h
Process temperature: -40 °C - 350 °C
Process pressure: 400 bar
... float-type flow meters are ideal for applications with high temperatures and pressure conditions (pressure up to 400 bar, temperature -40 °C to +350 °C) and for measurement of cloudy and corrosive media. Applications: The ...

Mass flow rate: 24 kg/h - 48,000 kg/h
Process temperature: -40 °C - 130 °C
Precision: 0.2 %
... mass flow meters are your go-to general-purpose mass flow meter. An affordable Coriolis mass flowmeter you can rely on Achieve robust, ...

Volumetric flow rate: 0 l/min - 1,000 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0.5 psi - 500 psi
... adjustment (via digital interface or local push button). Self-Diagnostic Tests. Local 2 x 16 characters LCD display* with adjustable back light (optional). XFM digital mass flow ...

Volumetric flow rate: 0 l/min - 350 l/min
Process temperature: -40 °C - 140 °C
Process pressure: 0 bar - 16 bar
Magnetic Inductive Flowmeter (Flow Meter) - All Metal - Stainless Steel - MIM Measuring range: 0.03 - 3 l/min ... 1.5 - 350 l/min liquids Accuracy: ±(0.8% of reading + 0.5% of FS) pmax: ...
KOBOLD INSTRUMENTATION

Process pressure: 0 bar - 15 bar
Precision: 5, 20 %
Repeatibility: 0.5, 1 %
... the liquid flow meter to be combined with several interface cables, ensures an optimal match and simplifies the integration of a liquid flow meter into a fluidic system. The ...
Sensirion
Your suggestions for improvement:
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining