Mass flow analog output flow meters

Volumetric flow rate: 10 l/h - 60,000 l/h
Process temperature: -40 °C - 150 °C
Process pressure: 10, 16 bar
Flow measuring and volume totalization of condensated steam and fuel, tank filling. Widely used in oil industry, measurement of honey, chocolate, paint, resin, inks, etc. Materials Body: EN 1.4404 (AISI 316L), PVC, ...
TECFLUID

Process temperature: 0 °C - 50 °C
Process pressure: 0.2 bar - 11 bar
Precision: 0.5, 1, 0.3 %
... 100 (extended turndown ratio on request) Analog & Digital The mass flow meters and controllers of the red-y smart series make use of the latest MEMS technology and ...
Vögtlin Instruments GmbH – Gas Flow Technology

Volumetric flow rate: 0 l/min - 3 l/min
Process temperature: -40 °C - 180 °C
Process pressure: 200 bar
... the robot’s dynamic behavior. The flowmeters have a very high resolution that supports extremely precise flow rate measurement across a very broad measuring range. Technical Data Linearity: ...

Process temperature: -25 °C - 180 °C
Process pressure: 0.6 MPa - 4 MPa
Precision: 0.5 %
... conductivity more than 5 μs/cm and flow range from 0.2 to 15 m/s. An electromagnetic flow meter is a volumetric Flowmeter that measures the flow velocity ...

... On-Board Flow Meter is a compact on-board fuel flow meter developed for our FP series Volumetric Flow Detector. It accepts pulse signal SIG A and SIG ...

Volumetric flow rate: 0 l/min - 500 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 70,000 Pa - 1,500,000 Pa
... before the flow meter. This flow meter can measure and display as little as 1/100 of the maximum flow range. In the past, it was necessary to use ...

Volumetric flow rate: 5 l/min - 80 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 10 bar
... form a Kármán vortex street in the flow. The distance between the individual vortices is constant. The frequency at which the vortices flow past a sensor depends on the flow velocity ...
SIKA

Process temperature: 0 °C - 95 °C
Precision: 1 %
... with lower accuracy) Nominal pressure - PN 16 Ambient temperature - 60 °C Outputs - IO-Link (configurable: Pulse output (up to 10 kHz), Analog output, Binary input/output Display ...

Volumetric flow rate: 3.6 l/h - 180 l/h
Process temperature: 0 °C - 105 °C
Process pressure: 0 bar - 10 bar
... Connection Output - Pulse, 0.3 - 2.2 V Coffee Machines Ensures perfect brews by measuring water flow accurately, detecting empty milk reservoirs and optimizing performance. Water Dispenser In ...

Process temperature: 60 °C
Precision: 1, 1.5 %
5000 series electromagnetic flow meter is a new flow meter that can be used in non-full tubes. It is ideal for water applications or any dirty liquids which is conductive ...
Holykell

Volumetric flow rate: 0.1 m³/h - 18,000 m³/h
Process temperature: -40 °C - 100 °C
Precision: 0.5 %
... (opt.) Output - Analog: passive 4÷20mA, Pulse: open collector Reverse Flow - Instant measure and totalization of reverse flow Flow Cutoff ...
SGM LEKTRA

Volumetric flow rate: 0.2 m³/s - 20 m³/s
Process temperature: -25 °C - 70 °C
Process pressure: 20 bar
Product of Taiwan, Non invasive design, no down time for installation, no pipe cutting, maintenance at any time, significantly reduce installation and maintenance costs. Tube installation-zero tube damage, no blockage, no leakage and ...

Process pressure: 0.2 bar - 11 bar
Precision: 0.3, 0.5, 1 %
Repeatibility: 0.2 %
... gas flow control for industrial scientific OEM applications Ideal for washdown environments MEMS sensor stability-Lifetime no-drift sensor warranty - if drift occurs, instrument will be repaired or ...
Sierra Instruments

Process pressure: 16 bar
Precision: 0.5 %
... of electromagnetic flowmeter display part flow meter and wireless communication module. The wireless communication module is equipped with IOT network card, that is SIM card. Its ...
Kamboda

Volumetric flow rate: 110,000 m³/h
Process temperature: -10 °C - 85 °C
Electromagnetic Flowmeter for Industrial Process Applications RPMag Compact or remote mounting options Pipe diameters from DN10 to DN2000 Measurement range from 0.1-110,000 m3/hr PTFE or rubber linings, 316 stainless ...
LTH Electronics Ltd

Volumetric flow rate: 1 l/h - 200,000 l/h
Process temperature: -20 °C - 65 °C
Process pressure: 15.6 bar - 39.2 bar
The Alia AVF250 flowmeter is commonly used in location that required on-site analog flow indication. The meter accurately measures small volumes / wide ranges of liquids, ...

Process temperature: -10 °C - 60 °C
Precision: 0.2 %
... entire sensor body at equal area, measure and report the average flow rate over the full diameter of the pipe. The specific design of the multi-electrode sensor compensates for variable flow profiles, ...

Process temperature: -40 °C - 80 °C
Precision: 0.5 %
Repeatibility: 0.1 %
Ultrasonic flow meters that use transit-time methods to measure flow. Introduction D118i is an advanced flow meter, which applies our patented ...
Gentos

Volumetric flow rate: 0.1 l/min - 90 l/min
Process temperature: -20 °C - 160 °C
Process pressure: 16, 10 bar
... of the medium to a minimum compared to normal variable area flow meters. Typical applications The variable area flowmeter and switch model DS07 is used for measuring and monitoring ...
PKP PROZESSMESSTECHNIK GMBH

Process temperature: -40 °C - 300 °C
Process pressure: 16 bar - 420 bar
LTD Series General Electron Flowmeter (hereafter call flowmeter), is a precise flowmeter to measure the flow of liquid in the tube. This flowmeter is a patent right product, ...
Shanghai Yinuo Instrument Co., Ltd

Process temperature: 0 °C - 50 °C
Process pressure: 0.45 MPa
Precision: 1, 0.35 %
... may be selected by the customer:±8V-±16V double-end power supply and +14V-+28V single–end power supply; digital or analog signal input and output; SEMI standard mechanical dimensions; ...
Beijing Sevenstar Flow Co., Ltd.

Volumetric flow rate: 20 l/h - 640,000 l/h
Process temperature: 0 °C - 120 °C
Process pressure: 0.1 bar - 11 bar
Magnetic-inductive flow meter VOLUMTEC Construction according to hygienic design standards, all Measurement in both flow directions Adjustability of the illuminated LC-Display Self-monitoring ...

Volumetric flow rate: 20 l/h - 300 l/h
Process temperature: -40 °C - 80 °C
Process pressure: 1.8 bar - 3.4 bar
what is Diesel Flow Meter? The diesel flow meter is a device to measure linear, nonlinear, mass or wide flow rate and volume flow ...
Flowtech Measuring Instruments Pvt. Ltd.

Volumetric flow rate: 0 m³/h - 1,133 m³/h
Process temperature: 150 °F
Process pressure: 100 psi
... PLUS™ FLOW MEASUREMENT FOR GASES AND LIQUIDS The Flo-Tronic Plus™ is based on a standard Flo-Meter™ with or without a manual flow control valve. It provides visual ...

Process temperature: 5 °C - 50 °C
Precision: 1.5, 1 %
... alarm settintg. ・Change of the calibration temperature, etc RS485 communication. Pulse output for totalized flow. Control of flow in the case of needle valve. CE
KOFLOC Corp.
Your suggestions for improvement:
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining